Series CD
2A, 60Vdc Optically Isolated, Short-Circuit Protected
DC Solid-State Relay
Part*
Number
DESC Drawing Relay Description
Number
CD00CFW
CD00CFY
CD01CFW
90091-008
Basic Solid-State Relay (SSR)
SSR with Control Status
CD01CFY 90091-006
CD20CDW
SSR with Short-Circuit Protection
CD20CDY 90091-004
CD21CDW
SSR with Short-Circuit Protection
CD21CDY 90091-002
and Control Status
* The Y suffix denotes parameters tested to MIL-PRF-28750 specifications.
The W suffix denotes parameters tested to Teledyne specifications.
For surface mount (SMT), add “S” prefix to part number. Example:
SCD00CFW
ELECTRICAL SPECIFICATIONS
FEATURES
• Available with short circuit/current
overload protection
• Available with input status monitor
• TTL and CMOS compatible control
• Low ON resistance power FET output
• Fast switching speed
• Meets 28 Vdc system requirements of
MIL-STD-704
• Optical isolation
• Low profile hermetic ceramic package
• Built and tested to the requirements of
MIL-PRF-28750
(-55°C TO +105°C UNLESS OTHERWISE NOTED)
DESCRIPTION
INPUT (CONTROL) SPECIFICATION
When used in 2 terminal configuration
This all solid-state relay utilizes the
latest technology to provide a low ON
(TTL or direct control) (See Fig. 1)
Min Typ Max Units
resistance. The control (input) and load
(output) are optically isolated to protect
Input Current @ VIN = 5 Vdc (See Fig. 2)
14 15 mA
input logic circuits from voltage and
current transients which can occur on
Turn-Off Voltage (Guaranteed Off)
1.5 Vdc
the output supply. The optical isolation
also provides a full floating output, thus
Turn-On Voltage (Guaranteed On)
3.8
allowing the load to be connected to
Vdc either output terminal. The control circuit
Reverse Voltage Protection
-32 Vdc
is buffered to enable the relay to be
driven directly from standard CMOS or
Input Supply Range (See Note 4)
3.8
6 Vdc
open collector TTL logic circuits.
Available options include short circuit
INPUT (CONTROL) SPECIFICATION
and current overload protection, which
provides complete protection for both
When used in 3 terminal configuration
the relay and the system wiring. This
(CMOS or open collector TTL) (See Fig. 1) Min Typ Max Units
omControl Current
.cVCONTROL = 5 Vdc
V = 18 Vdc
CONTROL
250 µA
1 mA
t4UControl Voltage Range
0 18 Vdc
eBias Supply Voltage (See Note 4)
3.8
6 Vdc
heBias Supply Current @ VBIAS = 5 Vdc
STurn-Off Voltage (Guaranteed Off)
14 15 mA
3.2 Vdc
taTurn-On Voltage (Guaranteed On)
0.3 Vdc
feature not only provides protection
should a short or overload occur while
the relay is on, but will also provide
protection should the relay be switched
into a short. In either case, the relay will
sense the short circuit condition and
then block it indefinitely until the short is
removed and the unit is reset by cycling
the input control. The second option is a
status output, which provides a built-in-
test function. This feature checks the
input circuitry of the relay and provides a
logic (0) low when the input circuit is
turned on and operational. Both options
are available either together or
separately as standard features.
www.Da© 2002 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
CD 41
CD\072002\Q1




CD21CDY pdf, 반도체, 판매, 대치품
www.DataSheet4U.com
Series CD
NORMALIZED ON RESISTANCE VS JUNCTION
TEMPERATURE
FIGURE 4 (SEE NOTE 5)
SERIES LIMIT BIAS RESISTOR VS BIAS VOLTAGE
FIGURE 8 (SEE NOTE 4)
NOTES:
1. Control input is compatible with CMOS or open collector
TTL (with pull up resistor).
2. The rated input voltage is 5V for all tests unless otherwise
specified.
3. Transient blocking voltage tests are performed per
MIL-STD-704 (28 Vdc systems).
4. For bias voltages above 6V, a series resistor is required.
Use the standard resistor value equal to or less than the
value found from Figure 8.
OUTPUT TURN-ON AND TURN-OFF TIMING
FIGURE 5
5. To calculate the maximum ON resistance for a given
junction temperature, find the normalized ON resistance
factor (NR) from Figure 4. Calculate the new ON
resistance as follows:
(CD00CD, CD01CD) R(ON) = NR • RON @ 25°C
(CD20CD, CD21CD) R(ON) = 0.2 • NR + 0.21
6. Overload testing to the requirements of MIL-PRF-28750 is
constrained to the limits imposed by the short circuit
protection characteristics as defined in this specification.
System series inductance for “shorted-load” mode of
et4U.comTRIP CURRENT VS TIME
SheFIGURE 7 (SEE NOTE 6)
operation should be 30 µH maximum. Maximum repetition
rate into a shorted load should not exceed 10 Hz.
7. A status pull up resistor is required for proper operation of
the status output. Determine the current (Iso) required by
the status interface. Calculate the current (Is) through the
status resistor such that the sink current through the
status output is 2 mA. Select the status resistor such that
it does not allow more than 2 mA to flow through the
status output.
RSTATUS
=
V - 0.3V
STATUS
2 mA - Iso
8. Inductive loads should be diode suppressed. Input
transitions should be 1 ms duration and the input drive
should be a bounceless contact type.
www.DataCD 44
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS
CD\072002\Q1

4페이지












구       성 총 4 페이지수
다운로드[ CD21CDY.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
CD21CDW

(CD2xCxx) DC Soild State Relay

Teledyne Relays
Teledyne Relays
CD21CDY

(CD2xCxx) DC Soild State Relay

Teledyne Relays
Teledyne Relays

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵