Datasheet.kr   

IB235 데이터시트 PDF




HOBART에서 제조한 전자 부품 IB235은 전자 산업 및 응용 분야에서
광범위하게 사용되는 반도체 소자입니다.


PDF 형식의 IB235 자료 제공

부품번호 IB235 기능
기능 (IB235 / IB290) GAS Infrared Booster
제조업체 HOBART
로고 HOBART 로고


IB235 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 2 페이지수

미리보기를 사용할 수 없습니다

IB235 데이터시트, 핀배열, 회로
www.DataSheet4U.com
FOOD EQUIPMENT
Item # ________________________________
Quantity _______________________________
C.S.I. Section 11400
IB235 AND IB290
GAS INFRARED BOOSTER
STANDARD FEATURES
s Stainless steel frame.
s Stainless steel legs and adjustable feet.
s Stainless steel 17 gallon tank.
s Stainless steel finned heat exchanger coil.
s Woven ceramic fiber infrared burner.
s 235,000 or 290,000 BTU/hr input.
s Two indicator lights - power on and heat on.
s Two high limit controls, automatic and manual
resets.
s 12 H.P. recirculating pump motor.
s 120/60/1 voltage.
s Temperature/pressure relief valve.
s Drain valve.
s Solid state thermostat.
s Blocked vent switch.
s Air flow switch.
s Vent fan control.
s Connections for external air pressure switch.
SPECIFICATIONS
Hobart Model IB _____ which provides _____ GPH
(_____ GPM) of 180°F (82°C) rinse water when
supplied with ______ BTU/Hr. of natural or propane
gas. Shall have a stainless steel frame, legs, and
adjustable feet with a stainless steel 17 gallon tank
which meets the requirements of the ASME Boiler
and Pressure Vessel Code. Equipped with a woven
ceramic fiber infrared burner and stainless steel
finned heat exchanger coil. Shall be 120 volts,
60 cycle, single phase and include two indicator
lights, automatic and manual reset high limit controls,
drain valve, air flow switch, temperature/pressure
relief valve, and vent fan control. Listed by NSF
International and Certified by AGA and CGA. Shall
have the capability to comply with the National Fuel
Gas Code, NFPA 54.
Net Weight: 420 lbs.
Shipping Weight: 490 lbs.
GAS OPTIONS
(must choose one)
DataSheet4U.com
VENTILATION
u Natural
u Propane
Before installing any method of venting, contact the
local code authority or your gas supplier to make
sure that the final installation will be acceptable to
POWER CONTROL OPTIONS
(must choose one)
u ON/OFF power switch on booster.
u Integrated power control (with new Hobart
the authorities who have jurisdiction. The proper
method of venting is explained in detail in the
National Fuel Gas Code. Also see our Installation
Manual.
dishmachine only).
Details and Dimensions on Reverse Side.
ACCESSORIES
u Pressure regulating valve.
u Shock arrestor, pressure regulating valve,
pressure gauge kit.
u Inlet temperature gauge.
DataShee
BOOSTER SIZING CHART
Gas
Input
Recovery Rate @ 180°F (82.2°C)
Inlet Water Temperature
MBH
110° 120° 130° 140° 150°
235 GPH
Natural or Propane GPM
322
5.37
376
6.27
451
7.52
564 752
9.4 12.54
290 GPH 398 464 557 696 928
Natural GPM 6.63 7.74 9.28 11.6 15.47
280 GPH 384 448 538 672 896
Propane GPM 6.40 7.47 8.96 11.2 14.94
DataSheet4U.cRoamtings shown are for elevations up to 2,000 feet. For elevations over 2,000
feet, reduce ratings at the rate of 4% for each 1,000 feet above sea level.
DataSheet4 U .com
701 S Ridge Avenue, Troy, OH 45374 • 937-332-3000 • 1-800-960-1190





구       성 총 2 페이지수
다운로드[ IB235.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
IB235

(IB235 / IB290) GAS Infrared Booster

HOBART
HOBART
IB235

Bosch Replacement Tegulator

Transpo
Transpo

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵