General Description
The EMC1033 is an SMBus temperature sensor that
monitors up to three temperature zones and can
generate two system interrupts. With ±1°C measurement
accuracy, the EMC1033 provides a low-cost solution for
critical temperature monitoring applications. Features
include automatic resistance error correction and
programmable ideality factor configuration eliminating
both major sources of temperature measurement error.1
The EMC1033 generates two separate interrupts with
programmable thermal trip points. The THERM output
operates as a thermostat with programmable threshold
and hysteresis. The ALERT output can be configured
as a maskable SMBus alert with programmable
window comparator limits, or as a second THERM
output. Both interrupts are maintained in an 8-pin
package while a third temperature zone is added with
the anti-parallel diode technique. This allows the
EMC1033 to be pin compatible with the ADT7461,
ADM1032, LM99, and the MAX6649 with the advantage
of a third temperature zone.
1.Patents pending.
Features
„ Resistance Error Correction
„ Ideality Factor Configuration
„ Select 1 of 4 SMBus addresses with external resistor
„ Remote Thermal Zones
±1.0°C Accuracy (40°C to 80°C)
— 0.125°C resolution
„ Internal Thermal Zone
±3.0°C Accuracy (0°C to 85°C)
„ Maskable Interrupt using ALERT
„ One-shot Command during standby
„ Programmable temperature conversion rate
„ Extended temperature (-64°C to 191°C) available
„ Over-limit filtering with consecutive counter
„ Small 8-pin TSSOP lead-free RoHS compliant
package
Applications
„ Desktop and Notebook Computers
„ Thermostats
„ Smart batteries
„ Industrial/Automotive
Simplified Block Diagram
EMC1033
DP1
DN2
DN1
DP2
Switching
Current
Internal
Temp Diode
11-bit
delta-sigma
ADC
Remote Temp
Register 1
Remote Temp
Register 2
Internal Temp
Register
Status Register
Address Pointer Register
Conversion Rate Register
High Limit Registers
Low Limit Registers
THERM Limit Register
THERM Hysterisis Register
Configuration Register
Interrupt Masking
SMCLK
SMDATA
ALERT
THERM
SMSC EMC1033
DATASHEET
Revision 1.2 (12-18-07)




EMC1033 pdf, 반도체, 판매, 대치품
1°C Triple SMBus Sensor with Resistance Error Correction
Datasheet
Table 1.3 Absolute Maximum Ratings
PARAMETER
Supply Voltage VDD
Voltage on ALERT/THERM2, SMDATA and
SMCLK pins
Voltage on any other pin
Operating Temperature Range
Storage Temperature Range
Lead Temperature Range
Package Thermal Characteristics for MSOP-8
Power Dissipation
Thermal Resistance (at 0 air flow)
ESD Rating, All Pins (Human Body Model)
RATING
-0.3 to 5.0
-0.3 to 5.5
-0.3 to VDD+0.3
-40 to +125
-55 to +150
Refer to JEDEC
Spec. J-STD-020
TBD
109.6
2000
UNIT
V
V
V
°C
°C
°C/W
V
Note:
Stresses above those listed could cause damage to the device. This is a stress rating only
and functional operation of the device at any other condition above those indicated in the
operation sections of this specification is not implied. When powering this device from
laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be
exceeded or device failure can result. Some power supplies exhibit voltage spikes on their
outputs when the AC power is switched on or off. In addition, voltage transients on the AC
power line may appear on the DC output. If this possibility exists, it is suggested that a clamp
circuit be used.
Revision 1.2 (12-18-07)
4
DATASHEET
SMSC EMC1033

4페이지










EMC1033 전자부품, 판매, 대치품
1°C Triple SMBus Sensor with Resistance Error Correction
Datasheet
Chapter 3 System Management Bus Interface Protocol
A host controller, such as an SMSC I/O controller, communicates with the EMC1033 via the two wire
serial interface named SMBus. The SMBus interface is used to read and write registers in the
EMC1033, which is a slave-only device. A detailed timing diagram is shown in Figure 3.1.
SMCLK
TLOW
TR
THIGH
TF
THD:STA
TSU:STO
THD:STA
THD:DAT TSU:DAT
TSU:STA
SMDATA
TBUF
P S S - Start Condition
S P - Stop Condition P
Figure 3.1 System Management Bus Timing Diagram
The EMC1033 implements a subset of the SMBus specification and supports Write Byte, Read Byte,
Send Byte, Receive Byte, and Alert Response Address protocols. as shown. In the tables that describe
the protocol, the “gray” columns indicate that the slave is driving the bus.
3.1 Write Byte
START
1
The Write Byte protocol is used to write one byte of data to the registers as shown below:
Table 3.1 SMBus Write Byte Protocol
SLAVE ADDRESS
7
WR
1
ACK
1
COMMAND
8
ACK
1
DATA
8
ACK
1
STOP
1
3.2 Read Byte
The Read Byte protocol is used to read one byte of data from the registers as shown below:
Table 3.2 SMBus Read Byte Protocol
START SLAVE ADDRESS
17
WR
1
ACK
1
COMMAND
8
ACK
1
START
1
SLAVE ADDRESS
7
RD
1
ACK
1
DATA
8
NACK
1
STOP
1
3.3
Send Byte
The Send Byte protocol is used to set the Internal Address Register to the correct Address. The Send
Byte can be followed by the Receive Byte protocol described below in order to read data from the
register. The send byte protocol cannot be used to write data - if data is to be written to a register then
the write byte protocol must be used as described in subsection above. The send byte protocol is
shown in Table 3.3, “SMBus Send Byte Protocol,” on page 7.
FIELD:
Bits:
START
1
SMSC EMC1033
Table 3.3 SMBus Send Byte Protocol
SLAVE ADDR
7
WR ACK
11
REG. ADDR
8
7
DATASHEET
ACK
1
STOP
1
Revision 1.2 (12-18-07)

7페이지



구       성총 24 페이지
다운로드[ EMC1033.PDF 데이터시트 ]
구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

전력 반도체 판매 ( IGBT, TR 모듈, SCR, 다이오드 모듈 )

상호 : 아이지 인터내셔날

사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ]



링크공유

링크 :

관련 데이터시트

부품번호상세설명 및 기능제조사
EMC1033

Triple SMBus Sensor

SMSC
SMSC

DataSheet.kr    |   2020   |  연락처   |  링크모음   |   검색  |   사이트맵