Datasheet.kr   

X40411 데이터시트 PDF




Intersil Corporation에서 제조한 전자 부품 X40411은 전자 산업 및 응용 분야에서
광범위하게 사용되는 반도체 소자입니다.


PDF 형식의 X40411 자료 제공

부품번호 X40411 기능
기능 (X40410 - X40415) Dual Voltage Monitor
제조업체 Intersil Corporation
로고 Intersil Corporation 로고


X40411 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 24 페이지수

미리보기를 사용할 수 없습니다

X40411 데이터시트, 핀배열, 회로
®
Data Sheet
X40410, X40411, X40414, X40415
4kbit EEPROM
March 28, 2005
FN8116.0
Dual Voltage Monitor with Integrated CPU
Supervisor
FEATURES
• Dual voltage detection and reset assertion
—Standard reset threshold settings
See Selection table on page 2.
—Adjust low voltage reset threshold voltages
using special programming sequence
—Reset signal valid to VCC = 1V
—Monitor three voltages or detect power fail
• Independent Core Voltage Monitor (V2MON)
• Fault detection register
• Selectable power-on reset timeout (0.05s,
0.2s, 0.4s, 0.8s)
• Selectable watchdog timer interval (25ms,
200ms,1.4s, off)
• Low power CMOS
—25µA typical standby current, watchdog on
—6µA typical standby current, watchdog off
• 4Kbits of EEPROM
—16 byte page write mode
—5ms write cycle time (typical)
www.DataSheet4U.com
• Built-in inadvertent write protection
—Power-up/power-down protection circuitry
—Block lock protect none or 1/2 of EEPROM
• 400kHz 2-wire interface
• 2.7V to 5.5V power supply operation
BLOCK DIAGRAM
• Available packages
—8-lead SOIC, TSSOP
• Monitor Voltages: 5V to 0.9V
• Memory Security
• Independent Core Voltage Monitor
APPLICATIONS
• Communication Equipment
—Routers, Hubs, Switches
—Disk Arrays, Network Storage
• Industrial Systems
—Process Control
—Intelligent Instrumentation
• Computer Systems
— Computers
—Network Servers
DESCRIPTION
The X40410/11/14/15 combines power-on reset con-
trol, watchdog timer, supply voltage supervision, and
secondary voltage supervision, and Block Lockpro-
tect serial EEPROM in one package. This combination
lowers system cost, reduces board space require-
ments, and increases reliability.
Applying voltage to VCC activates the power-on reset
circuit which holds RESET/RESET active for a period of
time. This allows the power supply and system oscilla-
SDA
SCL
VCC
(V1MON)
V2MON
Data
Register
Command
Decode Test
& Control
Logic
Threshold
Reset Logic
Fault Detection
Register
Status
Register
EEPROM
Array
Watchdog Timer
and
Reset Logic
User Programmable
VTRIP1
User Programmable
VTRIP2
+
-
VCC or
+ V2MON
Power-on,
Low Voltage
Reset
Generation
-
*X40410/11= V2MON*
X40414/15 = VCC
WDO
RESET
X40410/14
RESET
X40411/15
V2FAIL
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-352-6832 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc. 2005. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.




X40411 pdf, 반도체, 판매, 대치품
X40410, X40411, X40414, X40415
Figure 2. VTRIPX Set/Reset Conditions
VTRIPX
(X = 1, 2)
VCC/V2MON
WDO
VP
SCL 0
70
70
7
SDA
A0h
WATCHDOG TIMER
The Watchdog Timer circuit monitors the microprocessor
activity by monitoring the SDA and SCL pins. The micro-
processor must toggle the SDA pin HIGH to LOW period-
ically, while SCL also toggles from HIGH to LOW (this is
a start bit) followed by a stop condition prior to the expira-
tion of the watchdog time out period to prevent a WDO
signal going active. The state of two nonvolatile control
bits in the Status Register determines the watchdog timer
period. The microprocessor can change these watchdog
bits by writing to the X40410/11/14/15 control register
(also refer to page 19).
Figure 3. Watchdog Restart
.6µs
1.3µs
SCL
SDA
Timer Start
V1 AND V2 THRESHOLD PROGRAM PROCEDURE
(OPTIONAL)
The X40410/11/14/15is shipped with standard V1 and
V2 threshold (VTRIP1, VTRIP2) voltages. These values
will not change over normal operating and storage
conditions. However, in applications where the stan-
dard thresholds are not exactly right, or if higher preci-
sion is needed in the threshold value, the
X40410/11/14/15 trip points may be adjusted. The pro-
cedure is described below, and uses the application of
a high voltage control signal.
4
00h tWC
Setting a VTRIPx Voltage (x = 1, 2)
There are two procedures used to set the threshold
voltages (VTRIPx), depending if the threshold voltage
to be stored is higher or lower than the present value.
For example, if the present VTRIPx is 2.9 V and the
new VTRIPx is 3.2 V, the new voltage can be stored
directly into the VTRIPx cell. If however, the new setting
is to be lower than the present setting, then it is neces-
sary to “reset” the VTRIPx voltage before setting the
new value.
Setting a Higher VTRIPx Voltage (x = 1, 2)
To set a VTRIPx threshold to a new voltage which is
higher than the present threshold, the user must apply
the desired VTRIPx threshold voltage to the corre-
sponding input pin Vcc(V1MON), or V2MON. The
Vcc(V1MON) and V2MON must be tied together dur-
ing this sequence. Then, a programming voltage (Vp)
must be applied to the WDO pin before a START con-
dition is set up on SDA. Next, issue on the SDA pin the
Slave Address A0h, followed by the Byte Address 01h
for VTRIP1 and 09h for VTRIP2, and a 00h Data Byte in
order to program VTRIPx. The STOP bit following a
valid write operation initiates the programming
sequence. Pin WDO must then be brought LOW to
complete the operation.
Note: This operation does not corrupt the memory
array.
Setting a Lower VTRIPx Voltage (x = 1, 2)
In order to set VTRIPx to a lower voltage than the
present value, then VTRIPx must first be “reset” accord-
ing to the procedure described below. Once VTRIPx
has been “reset”, then VTRIPx can be set to the desired
voltage using the procedure described in “Setting a
Higher VTRIPx Voltage”.
FN8116.0
March 28, 2005

4페이지










X40411 전자부품, 판매, 대치품
X40410, X40411, X40414, X40415
BP: Block Protect Bit (Nonvolatile)
The Block Protect Bit, BP, determines which blocks of
the array are write protected. A write to a protected
block of memory is ignored. The block protect bits will
prevent write operations to half or none of the array.
Protected Addresses
BP (Size)
0 None
1 100h – 1FFh (256 bytes)
Array Lock
None
Upper Half of
Memory Array
PUP1, PUP0: Power-up Bits (Nonvolatile)
The Power-up bits, PUP1 and PUP0, determine the
tPURST time delay. The nominal power-up times are
shown in the following table.
PUP1
0
0
1
1
PUP0
0
1
0
1
Power-on Reset Delay (tPURST)
50ms
200ms (factory setting)
400ms
800ms
WD1, WD0: Watchdog Timer Bits (Nonvolatile)
The bits WD1 and WD0 control the period of the
Watchdog Timer. The options are shown below.
WD1
0
0
1
1
WD0
0
1
0
1
Watchdog Time Out Period
1.4 seconds
200 milliseconds
25 milliseconds
disabled (factory setting)
Writing to the Control Registers
Changing any of the nonvolatile bits of the control and
trickle registers requires the following steps:
– Write a 02H to the Control Register to set the Write
Enable Latch (WEL). This is a volatile operation, so
there is no delay after the write. (Operation pre-
ceded by a start and ended with a stop).
– Write a 06H to the Control Register to set the
Register Write Enable Latch (RWEL) and the WEL
bit. This is also a volatile cycle. The zeros in the data
byte are required. (Operation proceeded by a start
and ended with a stop).
– Write a one byte value to the Control Register that
has all the control bits set to the desired state. The
Control register can be represented as qxys 001r in
binary, where xy are the WD bits, s isthe BP bit and
qr are the power-up bits. This operation proceeded
by a start and ended with a stop bit. Since this is a
nonvolatile write cycle it will take up to 10ms to
complete. The RWEL bit is reset by this cycle and
the sequence must be repeated to change the non-
volatile bits again. If bit 2 is set to ‘1’ in this third step
(qxys 011r) then the RWEL bit is set, but the WD1,
WD0, PUP1, PUP0, and BP bits remain unchanged.
Writing a second byte to the control register is not
allowed. Doing so aborts the write operation and
returns a NACK.
– A read operation occurring between any of the
previous operations will not interrupt the register
write operation.
– The RWEL bit cannot be reset without writing to the
nonvolatile control bits in the control register, power
cycling the device or attempting a write to a write
protected block.
To illustrate, a sequence of writes to the device con-
sisting of [02H, 06H, 02H] will reset all of the nonvola-
tile bits in the Control Register to 0. A sequence of
[02H, 06H, 06H] will leave the nonvolatile bits
unchanged and the RWEL bit remains set.
FAULT DETECTION REGISTER
The Fault Detection Register (FDR) provides the user
the status of what causes the system reset active. The
Manual Reset Fail, Watchdog Timer Fail and three
Low Voltage Fail bits are volatile.
7 6543
LV1F LV2F 0 WDF 0
2 10
0 00
The FDR is accessed with a special preamble in the
slave byte (1011) and is located at address 0FFh. It
can only be modified by performing a byte write
operation directly to the address of the register and
only one data byte is allowed for each register write
operation.
There is no need to set the WEL or RWEL in the
control register to access this fault detection register.
7 FN8116.0
March 28, 2005

7페이지


구       성 총 24 페이지수
다운로드[ X40411.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
X40410

(X40410 - X40415) Dual Voltage Monitor

Intersil Corporation
Intersil Corporation
X40411

(X40410 - X40415) Dual Voltage Monitor

Intersil Corporation
Intersil Corporation

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵