DataSheet.es    


PDF MGDSI-20-Q-F Data sheet ( Hoja de datos )

Número de pieza MGDSI-20-Q-F
Descripción Industrial DC/DC Converter
Fabricantes Gaia 
Logotipo Gaia Logotipo



Hay una vista previa y un enlace de descarga de MGDSI-20-Q-F (archivo pdf) en la parte inferior de esta página.


Total 9 Páginas

No Preview Available ! MGDSI-20-Q-F Hoja de datos, Descripción, Manual

Industrial DC/DC CONVERTER
MGDI-10 Standard Input : 10W POWER Industrial
Grade
2:1 Standard Input
Single & Bi Outputs
Metallic case - 1.500 VDC Isolation
Low profile : 0,33 “ ( 8.5mm)
• Nominal power of 10 W without derating
• Wide temperature range : -40°C/+95°C case
• High efficiency up to 83 %
• Soft start
• Galvanic isolation 1.500 VDC
• Integrated LC EMI filter
• Permanent short circuit protection
• No optocoupler for high reliability
1-General
The MGDI-10 series is a full family of DC/DC
power modules designed for use in distributed
power architecture and are particularly suitable
for mobile or ground fixed applications in
transportation, industry and télécommunication
areas. These modules use a high frequency fixed
switching technic at 500 KHz providing excellent
reliability, low noise characteristics, high power
density and a low profile package. Standard
models are available with nominal input volta-
ges as 5, 12, or 24 volts in range of 4,5-5,5,
9-18 or 18-36 volts. The series include single
and bi output voltage choices of 3,3, 5, 12, 15,
+/-5, +/-12 or +/-15 volts.
No external heatsink is required for the MGDI-
10 series to supply 10W output power over the
case temperature range of -40°C up to 95°C.
The MGDI-10 series is designed in conformity
with safety standards EN60950 and UL1950.
All the modules are designed with LC network
filters to minimize reflected input current ripple
and output voltage ripple according to EN55022
and FCC Part 15J standard.
The modules include a soft-start, and a perma-
nent short circuit protection to ensure efficient
module protection. The soft-start allows current
limitation and eliminates inrush current during
start-up. The short circuit protection completely
protects the modules against short-circuits of
any duration by a shut-down and restores to
normal when the overload is removed.
The design has been carried out with surface
mount components and is manufactured in a
fully automated process to guarantee high
quality. Each module is tested and burned in
with a GAIA converter automated test equipment.
5
2-Product Selection
Single output model : MGDSI-10-
Bi output model
: MGDBI-10-
Input Voltage Range
Permanent
C : 4,5-5,5 VDC
F : 9-18 VDC
I : 18-36 VDC
Output
B : 3.3 VDC
C : 5 VDC or +/-5VDC
E : 12 VDC or +/-12VDC
F : 15 VDC or +/-15VDC
REDEFINING THE SOURCE OF POWER
© Gaia Converter FC97-006.08/05 Revision J
For locations, phone, fax, E-Mail see back cover

1 page




MGDSI-20-Q-F pdf
MGDI-10 Standard Input Series
Industrial
Grade
4- Functional Characteristics
Characteristics
Electric strength test voltage
Isolation resistance
Short circuit protection
Switching frequency
Conditions
Input to output
500 VDC
Short circuit
No load to full load
Limit or typical
Minimum
Minimum
Auto restart
Nominal
Performances
1.500 VDC / 1 min
100 Mohm
Permanent
480 KHz
5- Thermal Characteristics
Characteristics
Operating ambient temperature range
at full load
Operating case temperature range
at full load
Conditions
Ambient temperature *
Case temperature
Limit or typical
Minimum
Maximum
Minimum
Maximum
Performances
- 40°C
+ 71°C
- 40°C
+ 95°C
Storage temperature range
Non functionning
Minimum
Maximum
- 40°C
+ 105°C
* TNote * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 95°C (See Application Notes : Ambient versus case temperature).
6- Reliability Characteristics
Characteristics
Mean Time Between Failure (MTBF)
According to MIL-HDBK-217F
Conditions
Ground fixed (Gf)
Temperature
Case at 40°C
Case at 70°C
Performances
950.000 Hrs
380.000 Hrs
7- Environmental Qualifications
Characteristics
Humidity
Temperature
cycling
Vibration
(Sinusoidal)
Shock
(Half sinus)
Bump
(Half sinus)
Electrical
discharge
susceptibility
Electrical field
susceptibility
Electrical fast
transient
susceptibility
Conditions
Damp heat
Temperature
Number of cycles
Temperature change
Transfert time / Steady state time
Number of cycles
Frequency
Amplitude /acceleration
Number of shocks
Peak acceleration
Duration
Number of bumps
Duration
Peak acceleration
Air discharge level 4 kV
Contact discharge level 2kV
Air discharge level 8 kV
Contact discharge level 4 kV
Antenna at 1 m
Wave form : AM modulated 80 %, 1KHz
Test : 26 MHz to 1 GHz
Level 1 : 0.5 kV
Level 3 : 2 kV
Severity
93 % H.R 56 Days
40°C
200
-40°C / +71°C
40 min. / 20 min.
10 cycles in each axis
10 to 60 Hz/ 60 to 2000 Hz
0.7 mm/10 g
3 shocks in each axis
100 g
6 ms
2000 Bumps in each axis
6 ms
25 g
sanction A
sanction A
sanction B
sanction B
Value 10 V/m
sanction A
sanction B
© Gaia Converter FC97-006.08/05 Revision J
For locations, phone, fax, E-Mail see back cover
Test procedure
IEC 68-2-3
IEC 68-2-14
IEC 68-2-6
IEC 68-2-27
IEC 68-2-29
EN55082-2 with :
EN61000-4-2
IEC 801-2
EN55082-2 with :
EN61000-4-3
IEC801-3
EN55082-2 with :
EN61000-4-4
IEC801-4
5
5

5 Page










PáginasTotal 9 Páginas
PDF Descargar[ Datasheet MGDSI-20-Q-F.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MGDSI-20-Q-FIndustrial DC/DC ConverterGaia
Gaia

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar