부품번호 BXA30 기능
기능 (BXA15 / BXA30) Design Note 100 Rev
제조업체 Artesyn Technologies
로고 Artesyn Technologies 로고


BXA30 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 4 페이지수

미리보기를 사용할 수 없습니다

BXA30 데이터시트, 핀배열, 회로
www.DataSheet4U.com
BXA15 and BXA30 SERIES
Design Note 100 Rev. 01 - Feb. 1999
• Safety and the low voltage directive
• Electromagnetic Compatibility Immunity
• Electromagnetic Compatibility Conducted and
Radiated Interference
• Telecom and Distributed Power Architecture Features
• System Protection Features
• Thermal Considerations
• Input Impedance Considerations
1. Safety and the Low Voltage Directive
The BXA15 and BXA30 series is intended to be supplied only from a
SELV (Safe Extra Low Voltage) circuit or a TNV (Telecommunications
Network Voltage) power source which are insulated from the AC
mains by reinforced insulation. Basic isolation, tested to 1,500VDC,
for EN60950 and UL1950, is provided.
SELV
TNV
DC Distributed Power of 12V, 24V or 48V
Central Office -48V
2. Electromagnetic Compatibility Immunity
Good design practice dictates that the electronic system be immune
to noise interference. This practice has now been encapsulated in
European law in the form of the EMC directive. It is imperative that
any system on sale in the European Union meets the terms of the
EMC directive and thus carries the CE mark. To simplify system
compliance to the EMC Directive, the BXA15 and BXA30 have been
designed to meet and comply with the necessary immunity stan-
dards.
Description
Electro-Static
Discharge
Standard
EN61000-4-2
Compliance Level
4kV Contact
8kV Discharge
Radiated Immunity
IEC801-3
10V/m
Fast Transients/Bursts
Surges
EN61000-4-4
EN61000-4-5
2kV
0.5KV (40 Ohm
Generator,
Secondary surge
protection)
3. Electromagnetic Compatibility Conducted and
Radiated Interference
Radiated Interference:
The BXA15 and BXA30 series meet the harmonised standard
EN55022 level A and CISPR22 level A. The series almost meets the
requirements of level B. System performance to level B could be
assured with the appropriate enclosure.
Conducted Interference - Level A Internal Filter Option:
All three input voltage versions of the series, 12VDC, 24VDC and
48VDC, are available with an internal filter option which meets input
conducted noise per VDE0871/8-A or EN55022-A. To order a model
with the internal filter, add ‘-F’ after the model number eg. BXA15-
48S12-F.
Conducted Interference - Level B External Filter:
The addition of an external capacitor enables the BXA15 and
BXA30 products to meet VDE0871/8-B, EN55022-B and CISPR22-B
conducted noise limits. The test set-up is per VDE 0877 Part 1 fig.4
with the load < 10 cm's away from the test converter.
Input Voltage
48 Volt
24 Volt
12 Volt
Recommended External Cap.
Nippon Chemi-Con SXE series120uF, 100V
ITW PAKTRON Capstick series part number
405K100CS4, 4uF @ 100V
ITW PAKTRON 405K100CS4
2 * ITW PAKTRON 405K100CS4
capacitors in close parallel.
For height critical applications, the ITW Paktron capacitor offers a
low profile of <7mm.
Note on the test set up and system grounding:
The products meet input conducted noise VDE0878-B, EN55022-B
and CISPR22-B 10kHz - 30MHz, if the load is not more than 10
cm's away. Tightly parallel tracks or twisted pair wiring to the load
should be used. Long leads to the load could radiate common
mode noise, typically above 20 MHz, back to the input power leads.
Conducted emissions should be checked at a system level.
If the unit fails level B at a frequency greater then 20MHz, because
of system wiring, an additional external ‘Y-capacitor’ could be con-
nected between input ground and output common, to locally
decouple common-mode noise. This capacitor type is usually
intended for use in interference suppression between line and earth.
A recommended capacitor is EVOX-RIFA PME271Y422M or equiva-
lent.
4. Telecom and Distributed Power Architecture
Features
Input Undervoltage Protection:
Internally, the BXA15 and BXA30 series contain an undervoltage
lockout zener circuit. The converter should not be operated continu-
ously at levels between the ‘maximum guaranteed-off-threshold’
and the ‘minimum guaranteed-on-threshold.’
Nominal Input
Voltage
12
24
48
Maximum Off
Voltage
7.0
14
28
Minimum On
Voltage
8.8
17
34
PAGE 1




BXA30 pdf, 반도체, 판매, 대치품
www.DataSheet4U.com
Design Note Artesyn Technologies, 1999
The information and specifications contained in this design note are believed to be correct at time of publication. However, Artesyn
Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change
without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 4

4페이지












구       성 총 4 페이지수
다운로드[ BXA30.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
BXA3

3W Wide Input DC/DC Converters

Artesyn Technologies
Artesyn Technologies
BXA3-24S05J

DC-DC / Low Power Isolated Industrial

Emerson
Emerson

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵