DataSheet.es    


PDF RKY Data sheet ( Hoja de datos )

Número de pieza RKY
Descripción AC Input
Fabricantes TDK 
Logotipo TDK Logotipo



Hay una vista previa y un enlace de descarga de RKY (archivo pdf) en la parte inferior de esta página.


Total 8 Páginas

No Preview Available ! RKY Hoja de datos, Descripción, Manual

www.DataSheet4U.com
(1/8)
AC Input
Conformity to RoHS Directive
Single Output, Long Life, Three-phase Input UL/C-UL Approved
R Series RKY(1.5kW)
The RKY Series has 200V three-phase input specifications com-
patible with a large output of 1.5kW. This makes it possible to use
high power without having to worry about the current limitations of
AC lines. In addition, the size of this series is very compact;
92× 120× 237mm. These products can now be installed in narrow
spaces that previously seemed impossible
FEATURES
• Built-In, wide-range variable output function.
• Approved by safety standards (UL, C-UL). Conforms to the
Electrical Appliance and Material Safety Law.
• Conforms to standards for noise terminal voltage VCCI-A and
EN55022-A, for immunity EN61000-4-2, 3, 4, 5, 6, 8, 11 and
EN61000-6-2.
• 5-year limited warrantee
• It is a product conforming to RoHS directive.
APPLICATIONS
• Semiconductor fabrication equipment
• Communication devices
• Information processing devices
PART NUMBERS AND RATINGS
Output
voltage(V)
24
36
48
1500W
Current(A)
50
42
32
Part No.
RKY24-50R
RKY36-42R
RKY48-32R
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
002-02 / 20060413 / ea111_rky.fm

1 page




RKY pdf
www.DataSheet4U.com
(5/8)
Characteristics, Functions, and Applications
TERMINAL DESIGNATIONS AND FUNCTIONS
9 8 7 65 4
3
-RC +RC -PF +PF CB RV REF -S +S
10
V.ADJ
11 ON
L1 L2 L3
12
Terminal No.
1
2
3
Designations and functions
AC input terminals(L1, L2, L3)
Frame ground terminal(G)
DC output terminals(+, –)
4 Remote sensing terminals
5 Output voltage reference terminal (REF)
6 Output voltage adjustment terminal(RV)
7 Current balance terminal(CB)
8 Power failure terminal (PF)
9 Remote ON-OFF terminals(+RC, –RC)
10 Output voltage adjustment trim(V.ADJ)
11 Operation indicator LED(Green)
Connect to AC. 200 to 240V three-phase input line.
Connect to earth ground. This is connected to the case.
Connect to load.
When a problem occurs based on line drop from the power supply to the load, it is possible to
compensate for this using remote sensing. For information about connections, please refer to
the section on the remote sensing function.
This terminal is for a reference voltage for controlling an output voltage and used for a
master-slave operation or when using an output voltage adjustment function. Normally it is
shorted with a metal bar to an RV terminal.
This terminal is used for controlling output voltage from outside.
This terminal is used when several power supplies are connected in parallel to connect
the respective CB and –S terminals in parallel.
These terminals output an open mode signal if an output voltage drops to 60 % or lower
of a set voltage. They also output the signal if an output voltage is shut down due to an
operation of an error detecting circuit for over output voltage protection, fan alarm overheat pro-
tection, or overcurrent protection.
Output is turned ON-OFF by disconnecting-connecting the RC terminals (output ON
when open).
RC terminals are floating. Normally, ±RC terminals are shorted with a metal bar.
Adjusts output voltage.
This Green LED becomes indicated when voltage is output.
INSTALLATIONS
(1) Standard installation
(2)
(3)
Input terminal
50mm min.
FAN airflow
Power supply
Front
Vent hole
Back
Vent hole
FAN
Distance the fan surface at least 50 mm away from
other components. And install so as to provide heat-
outside air exchange.
Make sure not to obstruct the vent on the front
panel.
• All specifications are subject to change without notice.
002-02 / 20060413 / ea111_rky.fm

5 Page










PáginasTotal 8 Páginas
PDF Descargar[ Datasheet RKY.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
RK-0505SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RK-0509SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RK-051.8SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RK-0512SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar