No Preview Available ! 56F8300 Hoja de datos, Descripción, Manual

56F8300
3-Phase AC Induction Motor V/Hz Control
using Processor ExpertTM
Targeting Document
56F8300
16-bit Digital Signal Controllers
www.DataSheet4U.com
8300ACIMTD
Rev. 1
08/2005
freescale.com

1 page




56F8300 pdf
Table 1-1 Motor-Brake Specifications
Set Manufactured
Motor Specification
Brake Specification
Position Sensor (Encoder)
EM Brno, Czech Republic
Motor Type
AM40V
3-Phase AC Induction Motor
Pole-Number
4
Nominal Speed
Nominal Voltage
Nominal Current
Brake Type
1300rpm
3 x 200V
0.88A
SG40N
3-Phase BLDC Motor
Pole-Number
Nominal Speed
Nominal Voltage
Nominal Current
Type
Pulses per revolution
6
1500rpm
3 x 27V
2.6A
Baumer Electric
BHK 16.05A 1024-12.5
1024
The following software tools are needed for compiling, debugging, loading to the EVM, remote
control and monitoring, RUN/STOP Switch and UP/DOWN Buttons:
• Metrowerks CodeWarrior 6.0
• PC master software
• Processor Expert v. 2.92
Measured quantities include:
www.DataSheet4U.comDCBus voltage
• Power module temperature
• Rotor speed
The faults used for drive protection:
• Overvoltage (PC master software error message = “Overvoltage fault”)
• Undervoltage (PC master software error message = “Undervoltage fault”)
• Overcurrent (PC master software error message = “Overcurrent fault”)
• Overheating (PC master software error message = “Overheating fault”)
• Wrong hardware (PC master software error message = “Wrong HW used”)
The 3-phase AC Induction Motor V/Hz application can operate in two modes:
1. Manual Operating Mode
The drive is controlled by the RUN/STOP switch (S3). The motor speed is set by the UP (S2) and
DOWN (S1) push buttons (Figure 1-1). If the application runs and motor spinning is disabled
(i.e., the system is ready), the green user LED (LED2; see Figure 1-2 ) will blink. When motor
Freescale Semiconductor
3-Phase AC Induction Motor V/Hz Control, Rev. 1
5

5 Page





56F8300 arduino
EVM Jumper Settings
2.1 EVM Jumper Settings
For jumper settings, see the 56F8346 Evaluation Module Hardware User’s Manual, 56F8357
Evaluation Module Hardware User’s Manual or 56F8367 Evaluation Module Hardware
User’s Manual.
To execute the 3-phase AC Induction Motor Control V/Hz Application - Closed Loop, the
56F8300 Daughter Card requires the strap settings shown in Figure 2-2 and Table 2-1.
Note: When running the EVM target system in a stand-alone mode from Flash, in the
56F8346EVM the JG9 jumper must be set in the 1-2 configuration to disable the command
converter parallel port interface. In the 56F8357 or 56F8367 EVM, the JG3 jumper must be set
in the 1-2 configuration to disable the command converter parallel port interface.
www.DataSheet4U.com
Figure 2-2 56F8300EVM Daughter Card Jumper Reference
Freescale Semiconductor
3-Phase AC Induction Motor V/Hz Control, Rev. 1
11

11 Page







PáginasTotal 16 Páginas
PDF Descargar[ Datasheet 56F8300.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
56F83003-Phase AC Induction Motor V/Hz ControlFreescale Semiconductor
Freescale Semiconductor

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar