DataSheet.es    


PDF LC72336 Data sheet ( Hoja de datos )

Número de pieza LC72336
Descripción Single-Chip Microcontrollers with Built-In LCD Driver and PLL Circuits
Fabricantes Sanyo Semicon Device 
Logotipo Sanyo Semicon Device Logotipo



Hay una vista previa y un enlace de descarga de LC72336 (archivo pdf) en la parte inferior de esta página.


Total 16 Páginas

No Preview Available ! LC72336 Hoja de datos, Descripción, Manual

Ordering number : EN5157C
CMOS LSI
LC72336, 72338
Single-Chip Microcontrollers
with Built-In LCD Driver and PLL Circuits
Overview
The LC72336 and LC72338 are single-chip
microcontrollers for use in electronic tuners. These
products include on chip a PLL circuit that can operate at
up to 150 MHz and 1/3 duty LCD drivers. They feature a
highly efficient instruction set and powerful hardware.
Functions
• High-speed programmable divider
• Program memory (ROM)
— LC72336: 6143 × 16 bits (12 kB)
— LC72338: 8191 × 16 bits (16 kB)
• Data memory (RAM): 512 × 4 bits
• All instructions are one-word instructions
• Cycle time: 1.33 µs
• Stack: 8 levels
• LCD drivers: Up to 96 segments (1/3 duty, 1/3 bias)
• Serial I/O: Up to 3 channels (8-bit 3-wire type)
• External interrupts: 2 interrupts (INT0, INT1)
Interrupt on rising or falling edge (selectable)
• Internal interrupts: 3 interrupt
Two built-in timer interrupts and 1 serial I/O interrupt
• Nested interrupt levels: 4 levels
• D/A converter: 4 channels (8-bit PWM output)
• A/D converter: 4 channels
(6-bit successive approximation)
• General-purpose ports:
— Input ports: 8
— Output ports: 12 (16 maximum)
— I/O ports: 8 (20 maximum, can be switched between
input and output in bit units.)
• PLL block: Supports 4 types of dead zone control, and
includes a built-in unlock detection circuit.
Supports 12 different reference frequencies.
• Universal counter: 20 bits (Can be used for either
frequency or period measurement.)
• Timers: Eight types of time measurement
• Beep function: Six beep tones
• Reset: Built-in voltage detection type reset circuit
• Halt mode: Stops the controller operating clock.
• Operating supply voltage: 4.5 to 5.5 V (3.5 to 5.5 V if
only the controller block operates.)
Package Dimensions
unit: mm
3174-QFP80E
[LC72336, 72338]
SANYO: QIP80E
This LSI can easily use CCB that is SANYO’s original bus format.
• CCB is a trademark of SANYO ELECTRIC CO., LTD.
• CCB is SANYO’s original bus format and all the bus
addresses are controlled by SANYO.
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
O3097HA (OT)/13095HA (OT) No. 5157-1/16

1 page




LC72336 pdf
LC72336, 72338
Electrical Characteristics for the Allowable Operating Ranges
Parameter
Symbol
Conditions
min typ max
Input high-level current
IIH (1)
IIH (2)
IIH (3)
XIN: VI = VDD = 5.0 V
FMIN, AMIN, HCTR, LCTR: VI = VDD = 5.0 V
Ports PA, PE, PF, PG, PH, PK, and PM, SNS, HOLD,
HCTR, LCTR: No pull-down resistors on port PA,
VI = VDD = 5.0 V, with input mode selected
for ports PE, PF, PG, PK, and PM
2.0 5.0
4.0 10
15
30
3.0
Input low-level current
IIH (4)
IIL (1)
IIL (2)
IIL (3)
With pull-down resistors on port PA, VI = VDD = 5.0 V
XIN: VI = VSS
FMIN, AMIN, HCTR, LCTR: VI = VSS
Ports PA, PE, PF, PG, PH, PK, and PM, SNS, HOLD,
HCTR, LCTR: No pull-down resistors on port PA,
VI = VSS, with input mode selected
for ports PE, PF, PG, PK, and PM
50
2.0 5.0
4.0 10
15
30
3.0
Input floating voltage
Pull-down resistance
Hysteresis
VIF
RPD (1)
VH
With pull-down resistors on port PA
With pull-down resistors on port PA, VDD = 5 V
Ports PF, PG, and PK, LCTR
(in frequency measurement mode)
75
0.1 VDD
0.05 VDD
100 200
0.2 VDD
Output high-level voltage
Output low-level voltage
VOH (1)
VOH (2)
VOH (3)
VOH (4)
VOH (5)
VOH (6)
VOL (1)
VOL (2)
VOL (3)
VOL (4)
VOL (5)
VOL (6)
VOL (7)
VMID (1)
Ports PB and PC: IO = –1 mA
Ports PE, PF, PG, PK, PM, and PN: IO = –1 mA
EO1, EO2: IO = –500 µA
XOUT: IO = –200 µA
S1 to S32: IO = –20 µA
COM1, COM2, COM3: IO = –100 µA
Ports PB and PC: IO = 50 µA
Ports PE, PF, PG, PK, PM, and PN: IO = 1 mA
EO1, EO2: IO = 500 µA
XOUT: IO = 200 µA
S1 to S32: IO = 20 µA
COM1, COM2, COM3: IO = 100 µA
Port PJ: IO = 5 mA
S1 to S32: IO = ±20 µA
VDD – 2.0
VDD – 1.0
VDD – 1.0
VDD – 1.0
VDD – 1.0
VDD – 1.0
0.75
2/3 VDD ±
1.0
2.0
1.0
1.0
1.0
1.0
1.0
2.0
Output mid-level voltage
VMID (2) S1 to S32: IO = ±20 µA
VMID (3) COM1, COM2, COM3: IO = ±100 µA
1/3 VDD ±
1.0
2/3 VDD ±
1.0
VMID (4) COM1, COM2, COM3: IO = ±100 µA
1/3 VDD ±
1.0
Output off leakage current
AD conversion error
Reject pulse width
Power-down detection voltage
Pull-down resistance
Current drain
IOFF (1)
IOFF (2)
IOFF (3)
PREJ
VDET
RPD (2)
IDD (1)
IDD (2)
IDD (3)
IDD (4)
Ports PE, PF, PG, PK, PM, and PN
EO1 , EO2
Port PJ
ADI0 to ADI3: VDD (1)
SNS
TEST1, TEST2
VDD (1): fIN (2) = 130 MHz, Ta = 25°C
VDD (2): halt mode*, Ta = 25°C (Fig. 1)
VDD = 5.5 V, oscillator stopped, Ta = 25°C (Fig. 2)
VDD = 2.5 V, oscillator stopped, Ta = 25°C (Fig. 2)
–3.0
–100
–5.0
–1/2
2.7
3.0
10
12
0.45
+3.0
+100
+5.0
+1/2
50
3.3
5
1
Note: * In case of instruction execution for 20 steps at intervals of 1 ms, with the PLL, counter functions and other functions all stopped.
Unit
µA
µA
µA
µA
µA
µA
µA
V
k
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
µA
nA
µA
LSB
µs
V
k
mA
mA
µA
µA
No. 5157-5/16

5 Page





LC72336 arduino
Continued from preceding page.
Pin No.
Symbol
I/O
I/O type
LC72336, 72338
Function
Shared-function LCD driver segment output, general-purpose I/O, and serial I/O port
The IOS instruction is used to switch between the LCD driver segment output, general-
purpose I/O, and serial I/O functions, and to switch between input and output for the
general-purpose input port function.
• When used for segment output:
The function can be specified in bit units.
Segment output is specified with the IOS instruction (Pn = 0DH).
b0 = S17/PE0 0 ... Segment output
b1 = S18/PE1 1 ... PE0 to PE3 output
b2 = S19/PE2
b3 = S20/PE3
• When used as a general-purpose I/O port:
Input or output can be specified in bit units (1-bit I/O).
The general-purpose I/O port function is specified with the IOS instruction (Pn = 0).
39 S17/PE0
CMOS 3-value
38 S18/PE1/SCK2
output and
37
S19/PE2/SO2
I/O push-pull
b2 = SI/O2 0 ... General-purpose port
1 ... SI/O port
Input or output is specified with the IOS instruction in bit units.
PE ... Pn = 4 0 ... Input
36 S20/PE3/SI2
1 ... Output
• When used as a serial I/O port:
The serial I/O port function is specified with the IOS instruction (Pn = 0).
The contents of the serial I/O data buffer can be saved and loaded with the INR and
OUTR instructions.
Note: Pin setup states when used as a serial I/O port:
PE0 ... General-purpose I/O
PE1 ... SCK2 output in internal clock mode
SCK2 input in external clock mode
PE2 ... SO2 output
PE3 ... SI2 input
In clock stop mode, if this port is used as a general-purpose I/O port or as a serial I/O
port, the pins go to the input disabled high-impedance state. If used for segment output,
the pins are fixed at the low level.
The segment output port function is selected after a power-on reset.
Continued on next page.
No. 5157-11/16

11 Page







PáginasTotal 16 Páginas
PDF Descargar[ Datasheet LC72336.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
LC7233Single-Chip PLL and Microcontroller with LCD DriverSanyo Semicon Device
Sanyo Semicon Device
LC72336Single-Chip Microcontrollers with Built-In LCD Driver and PLL CircuitsSanyo Semicon Device
Sanyo Semicon Device
LC72338Single-Chip Microcontrollers with Built-In LCD Driver and PLL CircuitsSanyo Semicon Device
Sanyo Semicon Device
LC7233NSingle-Chip PLL and Microcontroller with LCD DriverSanyo Semicon Device
Sanyo Semicon Device

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar