Advanced Digital Temperature Controller
E5AN-H/E5EN-H
(96 x 96 mm and 48 x 96 mm)
www.DataSheet4U.com
CSM_E5AN-H_E5EN-H_DS_E_3_2
A New High-performance Controller: High Resolution, High Speed, and
High Input Accuracy.
Logic Operations and Preventive Maintenance Function. Plus Infrared
Port on Front Panel.
• High-resolution display with 5 digits/0.01°C display.
• High-speed sampling cycle of 60 ms.
• High Accuracy
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS
• Universal inputs on all models (thermocouple, PT, or analog input)
to handle various sensors with one Controller. Models also
available with Remote SP.
• A PV/SV-status display function can be set to automatically
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or
SV.
• Flexible contact outputs with logic operations (AND, OR, and
delays) set from the Support Software (CX-Thermo Ver. 4.0)
• Preventive maintenance for relays in the Temperature Controller
using a Control Output ON/OFF Counter.
• Model available with position-proportional control
96 × 96 mm
E5AN-H
48 × 96 mm
E5EN-H
Refer to Safety Precautions for E5@N/E5@N-H.
Refer to Operation for E5@N/E5@N-H for operating
procedures.
Main I/O Functions
Remote SP Input
• One
Event Inputs
• None
• Two
• Four
Universal Sensor Inputs
• Universal thermocouple/
Pt/analog
(current/voltage) inputs.
Indication Accuracy
• Thermocouple/Pt input:
±0.1% of PV
• Analog input:
±0.1% FS
Sampling Period
• 60 ms
PF Key
(Programmable
key function)
E5AN-H
E5EN-H
3-level Display
Simultaneously displays set items, such as the
PV, SV, and MV.
5-digit Display with high resolution of 0.01°C
Infrared port
USB
Auxiliary Outputs
• Two
• Three
Computer Support Software
CX-Thermo
Control Output 2
(built-in)
Output Unit
• SSR outputs • Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
• Auto/manual switching
• Temperature Controller
status display
• Simple program
function
• Logic operations
• Control output ON/OFF
count alarm
• PV change rate alarm
• Models available with
RS-485, RS-422, or
RS-232C
communications
Control Output 1
(built-in)
Output Unit
• SSR outputs • Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
1
E5AN-H/E5EN-H
www.DataSheet4U.com
E5EN-H
Size
Case
color
Power supply
voltage
100 to 240 VAC
Black
1/8 DIN
48 × 96 × 78
(W × H × D)
24 VAC/VDC
100 to 240 VAC
Silver
24 VAC/VDC
Control
method
Auxil-
iary
output
Control output 1/2
Control Output Unit × 2
2
Basic
SSR outputs × 2
Control Output Unit × 2
SSR outputs × 2
Control Output Unit × 2
3
SSR outputs × 2
Valve 2
Relay outputs × 2
Relay outputs × 2
Control Output Unit × 2
2
Basic
SSR outputs × 2
Control Output Unit × 2
SSR outputs × 2
Control Output Unit × 2
3
SSR outputs × 2
Valve 2
Relay outputs × 2
Relay outputs × 2
Control Output Unit × 2
Basic 2
Control Output Unit × 2
Control Output Unit × 2
Heater
Optional Functions
burn- Event Transfer
out inputs output
RSP
12
4 to 20-mA
input
12
4 to 20-mA
input
2
2
4 to 20-mA 4 to 20-mA
output
input
2
2
4 to 20-mA 4 to 20-mA
output
input
2
4 to 20-mA 4 to 20-mA
output
input
2
4 to 20-mA 4 to 20-mA
output
input
2
4 to 20-mA
input
2
4 to 20-mA 4 to 20-mA
output
input
12
4 to 20-mA
input
12
4 to 20-mA
input
2
2
4 to 20-mA 4 to 20-mA
output
input
2
2
4 to 20-mA 4 to 20-mA
output
input
2
4 to 20-mA 4 to 20-mA
output
input
2
4 to 20-mA 4 to 20-mA
output
input
2
4 to 20-mA
input
2
4 to 20-mA 4 to 20-mA
output
input
12
4 to 20-mA
input
2
2
4 to 20-mA 4 to 20-mA
output
input
12
4 to 20-mA
input
Model
E5EN-HAA2HBM-500
E5EN-HSS2HBM-500
E5EN-HAA2HHBFM-500
E5EN-HSS2HHBFM-500
E5EN-HAA3BFM-500
E5EN-HSS3BFM-500
E5EN-HPRR2BM-500
E5EN-HPRR2BFM-500
E5EN-HAA2HBMD-500
E5EN-HSS2HBMD-500
E5EN-HAA2HHBFMD-500
E5EN-HSS2HHBFMD-500
E5EN-HAA3BFMD-500
E5EN-HSS3BFMD-500
E5EN-HPRR2BMD-500
E5EN-HPRR2BFMD-500
E5EN-HAA2HBM-W-500
E5EN-HAA2HHBFM-W-500
E5EN-HAA2HBMD-W-500
Accessories (Order Separately)
Output unit Model
Specifications
Relay
output
E53-RN
SPST-NO, 250 VAC, 5 A (resistive load),
electrical life: 100,000 operations
Voltage
output
(for driving
SSR)
E53-QN
E53-Q3
E53-Q4
12 VDC (PNP), max. load current:
40-mA, with short-circuit protection
24 VDC (NPN), max. load current:
20-mA, with short-circuit protection
24 VDC (PNP), max. load current:
20-mA, with short-circuit protection
Current
output
E53-C3N
4 to 20-mA DC, load: 600 Ω max.,
resolution: approx. 10,000
E53-C3DN
0 to 20-mA DC, load: 600 Ω max.,
resolution: approx. 10,000
Linear
voltage
output
E53-V34N
E53-V35N
0 to 10 VDC, load: 1 kΩ min., resolution:
approx. 10,000
0 to 5 VDC, load: 1 kΩ min., resolution:
approx. 10,000
USB-infrared Conversion Cable
Model
E58-CIFIR
Terminal Cover
Connectable models
Model
E5AN-H
E5EN-H
E53-COV16
Note: The Terminal Cover comes with the E5CN-@@@-500 models.
Waterproof Packing
Connectable models
Model
E5AN-H
Y92S-P4
E5EN-H
Y92S-P5
Note: The Waterproof Packing is included with the Controller.
Current Transformers (CTs)
Hole diameter
5.8 dia.
12.0 dia.
Model
E54-CT1
E54-CT3
CX-Thermo Support Software
Model
EST2-2C-MV4
USB-Serial Conversion Cable
Model
E58-CIFQ1
4
4페이지 E5AN-H/E5EN-H
www.DataSheet4U.com
Alarm Outputs
Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).
Set value
Alarm type
Alarm output operation
When alarm value When alarm value
X is positive
X is negative
Description of function
0 Alarm function OFF
Output OFF
No alarm
1 Upper- and lower-limit *1
ON
OFF
LH
SP
*2
Set the deviation in the set point by setting the alarm
upper limit (H) and alarm lower limit (L).
2 Upper-limit
ON
OFF
X
SP
ON
OFF
X
SP
Set the upward deviation in the set point by setting
the alarm value (X).
3 Lower-limit
ON
OFF
X
SP
ON
OFF
X
SP
Set the downward deviation in the set point by setting
the alarm value (X).
4
Upper- and lower-limit range *1
ON
OFF
LH
*3
SP
Set the deviation in the set point by setting the alarm
upper limit (H) and alarm lower limit (L).
5
Upper- and lower-limit with
standby sequence *1
ON
OFF
LH
SP
*4
*5
A standby sequence is added to the upper- and
lower-limit alarm (1). *7
6
Upper-limit with standby sequence
ON
OFF
X
SP
ON
OFF
X
SP
A standby sequence is added to the upper-limit alarm
(2). *7
7
Lower-limit with standby sequence
ON
OFF
X
SP
ON
OFF
X
SP
A standby sequence is added to the lower-limit alarm
(3). *7
8
Absolute-value upper-limit
ON
OFF
X
0
ON X
The alarm will turn ON if the process value is larger
OFF 0 than the alarm value (X) regardless of the set point.
9 Absolute-value lower-limit
ON
OFF
X
0
ON X
The alarm will turn ON if the process value is smaller
OFF 0 than the alarm value (X) regardless of the set point.
10
Absolute-value upper-limit with
standby sequence
ON
OFF
X
0
ON X
A standby sequence is added to the absolute-value
OFF 0 upper-limit alarm (8). *7
11
Absolute-value lower-limit with
standby sequence
ON
OFF
X
0
ON X
A standby sequence is added to the absolute-value
OFF 0 lower-limit alarm (9). *7
12 LBA (alarm 1 type only)
--- *8
13 PV change rate alarm
--- *9
14
RSP absolute value upper limit *6
ON
OFF
X
0
ON
OFF
X
The alarm turns ON when the remote SP (RSP) is
larger than the alarm value (X). This alarm functions
0 in both Local SP and Remote SP Modes.
15
RSP absolute value lower limit *6
ON
OFF
X
0
ON
OFF
X
The alarm turns ON when the remote SP (RSP) is
smaller than the alarm value (X). This alarm
0 functions in both Local SP and Remote SP Modes.
*1. With set values 1, 4 and 5, the upper and lower limit values can
be set independently for each alarm type, and are expressed as
“L” and “H.”
*2. Set value: 1, Upper- and lower-limit alarm
Case 1
Case 2
Case 3 (Always ON)
L H SP
H < 0, L > 0
⏐H⏐ < ⏐L⏐
SP L H
H > 0, L < 0
⏐H⏐ > ⏐L⏐
H SP L
H L SP
SP H L
*3. Set value: 4, Upper- and lower-limit range
H < 0, L < 0
H < 0, L > 0
⏐H⏐ ≥ ⏐L⏐
H > 0, L < 0
⏐H⏐ ≤ ⏐L⏐
Case 1
Case 2
Case 3 (Always ON)
H < 0, L < 0
L H SP
SP L H
H SP L
H < 0, L > 0
⏐H⏐ < ⏐L⏐
H > 0, L < 0
⏐H⏐ > ⏐L⏐
H L SP
H < 0, L > 0
⏐H⏐ ≥ ⏐L⏐
H > 0, L < 0
SP H L
⏐H⏐ ≤ ⏐L⏐
*4. Set value: 5, Upper- and lower-limit with standby sequence
For Upper- and Lower-Limit Alarm Described Above
• Case 1 and 2
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
• Case 3: Always OFF
*5. Set value: 5, Upper- and lower-limit with standby sequence
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
*6. Displayed when there is a remote SP input.
*7. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Controllers User's Manual Basic Type (Cat. No. H156) for
information on the operation of the standby sequence.
*8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Controllers User's Manual Basic Type (Cat. No. H156) for
information on the loop burnout alarm (LBA).
*9. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Controllers User's Manual Basic Type (Cat. No. H156) for
information on the PV change rate alarm.
7
7페이지 | |||
구 성 | 총 16 페이지수 | ||
다운로드 | [ E5AR-T.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
E5AR-T | Advanced Digital Temperature Controller | Omron |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |