부품번호 GV2ME08 기능
기능 Manual Starter and Protector
제조업체 Steven Engineering
로고 Steven Engineering 로고


GV2ME08 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 6 페이지수

미리보기를 사용할 수 없습니다

GV2ME08 데이터시트, 핀배열, 회로
www.schneider-electric.us
GV2ME
GV2P21 with
GV2GH7 installed
Starters
TeSys® GV2 and GV3 Manual Starter and Protector
Refewr wtowC.DaatatalSohgee2t542U0.cComT0001
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual
disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in
one compact unit.
Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220
amps. The GV family of products may also be used in group motor installations in accordance with National Electric
Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts
and less wiring necessary for installation when compared to conventional panel designs.
The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual
combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P
or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also
be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter
construction. These products have UL-listed short circuit current rating from 10–100 KA depending on application size
and voltage. See www.us.telemecanique.com for more information.
How to Order
To order the basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal
setting from the table below. The thermal trip range and setting should be determined from the motor nameplate full-
load current.
Table 18.124:
Thermal
Setting
(A)
Maximum Horsepower Ratings
1Ø 3Ø
115 V 230 V 200 V 230 V 460 V
hp hp hp hp hp
575 V
hp
Group Motor
Applications
Max. Fuse or
Circuit Breaker
GV2/3M push button
Catalog
Number
$ Price
GV2/3P rotary handle
Catalog
Number
$ Price
0.11–0.16 — — — — — —
1200 A
GV2ME01a
159.
GV2P01
212.
0.16–0.25 — — — — — —
1200 A
GV2ME02a
159.
GV2P02
212.
0.25–0.40 — — — — — —
1200 A
GV2ME03a
159.
GV2P03
212.
0.40–0.63 — — — — — —
1200 A
GV2ME04a
180.
GV2P04
233.
0.63–1 — — — — 0.5 0.5
1200 A
GV2ME05a
180.
GV2P05
233.
1–1.6
— 0.1 —
— 0.75
1
1200 A
GV2ME06a
180.
GV2P06
233.
1.6–2.5
— 0.667 0.5
0.5
1
1.5
2.5–4
1/8 0.333 0.75
1
2
3
1200 A
1200 A
GV2ME07a
GV2ME08a
180.
180.
GV2P07
GV2P08
233.
233.
4–6.3
1/4 0.5 1.5 1.5
3
5
1200 A
GV2ME10a
180.
GV2P10
233.
6–10
0.5 1.5
2
3
5 7.5
1200 A
GV2ME14a
180.
GV2P14
233.
9–14 0.75 2 3 3 10 10
1200 A
GV2ME16a
224.
GV2P16
278.
13–18 1 3 5 5 10 15
1200 A
GV2ME20a
224.
GV2P20
278.
17–23 1.5 3
5 7.5 15 20
1200 A
GV2ME21a
224.
GV2P21
278.
20–25 2 3 5 7.5 15 20
1200 A
GV2ME22a
224.
GV2P22
278.
24–32 2 5 10 10 20 30
1200 A
GV2ME32
224.
GV2P32
278.
9–13
12–18
0.5 1.5
0.75 2
3
5
3 7.5 10
5 7.5 10
——
GV3P13
404.
New! GV3P18
404.
17–25 1.5 3 7.5 7.5 15 20
——
GV3P25
404.
23–32 2 3 10 7.5 20 25
——
GV3P32
404.
30–40 3 5 10 10 25 30
——
GV3P40
504.
37–50
3 7.5 15 10 30 40
——
GV3P50
504.
48–65 3 10 20 15 40 50
——
GV3P65
504.
a For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
GV3P
GV7RE20
Table 18.125:
Thermal
Setting
(A)
Maximum Horsepower Ratings
1Ø 3Ø
115 V 230 V 200 V 230 V 460 V
hp hp hp hp hp
575 V
hp
12–20
15–25
25–40
30–50
48–80
60–100
90–150
132–220
— — — 5 10 15
— — — 7.5 15 20
— — — 10 30 30
— — — 15 30 40
— — — 30 60 75
— — — 30 75 100
— — — 50 100 150
— — — 75 150 200
Toggle Operator
Standard Interrupt
High Interrupt
Catalog
Number
GV7RE20
GV7RE25
GV7RE40
GV7RE50
GV7RE80
GV7RE100
GV7RE150
GV7RE220
$ Price
417.
417.
417.
417.
417.
456.
502.
502.
Catalog
Number
GV7RS20
GV7RS25
GV7RS40
GV7RS50
GV7RS80
GV7RS100
GV7RS150
GV7RS220
$ Price
813.
813.
813.
813.
813.
891.
978.
978.
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
E164864
CCN NLRV
LR81630
Class 3211 05
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-33
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com




GV2ME08 pdf, 반도체, 판매, 대치품
www.schneider-electric.us
GV2GH7
LAD31
LAD311
Starters Accessories
TeSys® GV2 Manual Starters and Protectors
Refewr wtowC.DaatataloShge2et540U2.cComT0001
Table 18.136: GV2 Mounting Accessories
Description
Common mounting plate
Adapter plate
Combination block
7.5 mm compensation plate
Mounting plate
Application
For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor.
(supplied with GV1G02 connector)
For screw mounting of GV2M
Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor
Interconnect GV2 and LC1D09 thru D32
Interconnect GV2 and LC1D09 thru D32 mounted on LAD31
To allow mounting of GV2M and GV2P on a common bus bar
For mounting GV2ME or GV2P and contactor LC1D09 thru D32
Standard
Pack b
Catalog Number
1 GK2AF01
10 GV2AF02
10 GV2AF01
10 GV2AF3
10 GV2AF4
10 GV1F03
10 LAD31
10 LAD311
Table 18.137: GV2 Cabling Accessories—Bus Bars
Description
3-Pole, 63 A Bus Bar
Application
For feeding 2 GV2 starters
For feeding 3 GV2 starters
For feeding 4 GV2 starters
For feeding 5 GV2 starters
Pitch
45
54
72
45
54
45
54
72
54
Standard Pack b
1
1
1
1
1
1
1
1
1
Catalog Number
GV2G245
GV2G254
GV2G272
GV2G345
GV2G354
GV2G445
GV2G454
GV2G472
GV2G554
Table 18.138: GV2 Other Cabling Accessories
Description
Application
Terminal blocks
Top feed for use with bus bars
Bottom feed, to be used with bus bars; can be fitted with GV1L3
current limiter
Protective end cover
To cover unused bus bar outlets
3-pole flexible connector
For connecting a GV2 to an LC1D09 thru D25 contactor
Conduit adapter (12" NPT)
Incoming line insulator
For GV2P when used in UL 508 Type E applicationsa
a Cannot be used with front-mounted auxiliary contact block.
Standard Pack b Catalog Number
1 GV1G09
1 GV2G05
5 GV1G10
10 GV1G02
1 GV2AK1
10 GV2GH7
Table 18.139: GV2 Other Accessories
Description
Visible isolation block - GV2P
Current limiter - GV2M
Through-Door operator - GV2P
Application
Front mount, 3-pole visible isolation on incoming side of GV2P
Increases interrupt capacity when attached to GV2M
For operating GV2P through enclosure door (red handle, yellow
legend plate) For NEMA 1 use. IP54
Standard Pack b Catalog Number
1 GV2AK00
1 GV1L3
1 GV2AP02
Table 18.140: GV2 Enclosures
Description
Mounting
Enclosures for GV2M
Surface mount
with or without accessories
(maximum of 1 accessory
Flush mount
on right and left)
Enclosures are not UL or CSA listed. Flush mount reduced width
(max. of 1 accessory on right)
Rating
NEMA 1, IP41
IP55
NEMA 1, IP41
IP55
NEMA 1, IP41
IP55
Catalog Number
GV2MC01
GV2MC02
GV2MP01
GV2MP02
GV2MP03
GV2MP04
Table 18.141: GV2 Enclosures Accessories
Description
Type
Padlocking device for GV2M (when
padlocked, starter is automatically in Off
position)
Spring return
Mushroom head stop push button
(40 mm, red) c
Latching
Key release (Ronis key no. 455)
Turn to Release
Latching / Padlockable Turn to Release
Sealing kit
For enclosures GV2MC01 and GV2MP01
110 V
110 V
110 V
110 V
Green
Red
Orange
White
Pilot Light (neon)
220/240 V
220/240 V
220/240 V
220/240 V
Green
Red
Orange
White
380/440 V
380/440 V
380/440 V
380/440 V
b Orders must specify multiples of quantities listed.
c Supplied with IP55 sealing kit.
Green
Red
Orange
White
Standard Packb Catalog Number
1 GV2V01
1 GV2K011
1 GV2K021
1 GV2K031
1 GV2K04
10 GV2E01
10 GV2SN13
10 GV2SN14
10 GV2SN15
10 GV2SN17
10 GV2SN23
10 GV2SN24
10 GV2SN25
10 GV2SN27
10 GV2SN33
10 GV2SN34
10 GV2SN35
10 GV2SN37
$ Price Each
21.60
7.10
14.0
3.20
3.20
5.40
6.20
12.30
$ Price Each
23.30
23.30
23.30
28.70
28.70
34.20
34.20
34.20
34.20
$ Price Each
34.20
34.20
3.60
14.30
16.20
15.00
$ Price Each
71.40
117.00
135.00
$ Price Each
54.00
78.00
31.10
54.00
27.90
49.70
$ Price Each
26.90
35.90
104.00
52.00
117.00
18.00
26.90
GV2AF3 / GV2AF4
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-37
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4페이지












구       성 총 6 페이지수
다운로드[ GV2ME08.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
GV2ME01

Manual Starter and Protector

Steven Engineering
Steven Engineering
GV2ME02

Manual Starter and Protector

Steven Engineering
Steven Engineering

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵