NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3)
DESCRIPTION
The Connor-Winfield Stratum 3 Simplified Control
Timing Module acts as a complete system clock module for general
Stratum 3 timing applications. The MSTM is designed for
external control functions. Full external control input allows for
selection and monitoring of any of four possible operating states:
1) Holdover, 2) External Reference #1, 3) External Reference
#2, and 4) Free Run. The table below illustrates the control signal
inputs and corresponding operational states:
In the absence of External Control Inputs (A,B), the
MSTM enters the Free Run mode and signals an External Alarm.
The MSTM will enter other operating modes upon application of
a proper control signal. Mode 1 operation (A=1, B=0) results in
an output signal that is phase locked to the External Reference
Input #1. Mode 2 operation (A=0, B=1) results in an output signal
that is phase locked to External Reference Input #2. Holdover
mode operation (A=1, B=1) results in an output signal at or near
the frequency as determined by the latest (last) locked-signal input
values and the holdover performance of the MSTM.
Alarm signals are generated at the Alarm Output during
Holdover and Free Run operation. Alarm Signals are also
generated by loss-of-lock, loss of Reference, and by a Tune-Limit
indication from the PLL. A Tune-Limit alarm signal indicates
that the VCXO tuning voltage is approaching within 10% the limits
of its lock capability and that the External Reference Input may
be erroneous. A high level indicates an alarm condition. Real-
time indication of the operational mode is available at unique
operating mode outputs on pins 1-4.
Control loop filters effectively attenuate any reference
jitter and smooth out phase transients.
MSTM-S3 PIN ASSIGNMENT
+5Vdc
EX REF 1
GND
EX REF 2
GND
CLK_OUT
GND
SYNC_OUT
GND
BOTTOM VIEW
HOLDOVER
REF 1
REF 2
FRERUN
GND
ALARM OUT
CNTL A
CNTL B
PLL TVL
CNTL A
CNTL B
EX REF 1
EX REF 2
0
1
2
2:4 3
BLOCK DIAGRAM
FRERUN
REF 1
REF 2
HOLDOVER
PLL TVL
FREE RUN
HOLDOVER
2:1
MUX
PHASE
COMPARATOR
LOCK AND
DETECTION
DAC
FILTERS
TUNING
VOLTAGE
MONITOR
PLL TVL
DAC
STRATUM3
VCXO
FIFO
STRATUM3
TCXO
MSTM-S3
ALARM
OUT
2:1
MUX
SYNC_OUT
CLK_OUT
CONTROL
INPUT
AB
www0.DataS0heet4U.com
External
1 0 Reference
#1
External
0 1 Reference
#2
11
OPERATIONAL MODE
Free Run (Default)
Normal
Tune Limit
LOS + LOL
Normal
Tune Limit
LOS + LOL
Holdover
REF 1
0
1
1
1
0
0
0
0
REF 2
HLDOVER
FRERUN
PLL_TVL*
ALARM
OUTPUT
00 10 1
00000
000 11
0000 1
10 0 0 0
100 11
1000 1
0 100 1
INT Specifications subject to change without notice.
DATA SHEET #: _T_M__0_0_7______ PAGE___1___ OF ___6____ REV:__0_2_____ DATE:___6_/_2_/_9_9____ © Copyright 1999 Connor-Winfield all rights reserved.

1 page




MSTM-S3 pdf
C O N N O R THE CONNOR-WINFIELD CORP.
W I N F I E L D 2111 COMPREHENSIVE DRIVE.
AURORA, IL 60505.
FAX (630) 851-5040.
PHONE (630) 851-4722
HTTP://WWW.CONWIN.COM
NETWORK ELEMENT TIMING GENERATOR
STRATUM 3 SIMPLIFIED CONTROL
TIMING MODULES (MSTM-S3)
MSTM-S3
PIN #
1 HOLDOVER
2 REF _1
3 REF_2
4 FRERUN
5 Gnd
6 ALARM_OUT
7 CNTL_A
8 CNTL_B
9 PLL_TVL
10 Gnd
11 SYNC_OUT
12 Gnd
13 CLK_OUT
14 Gnd
15 EX_REF_2
16 Gnd
17 EX_REF_1
18 +5 Vdc
PIN DESCRIPTION
-Output. High when the control inputs select Holdover.
-Ouput. High when the control inputs select EX REF_1.
-Output. High when the control inputs select EX REF_2.
-Output. High when the control input selects Free Run.
-Ground.
-Ouput. =1,If (FRERUN + HOLDOVER + LOS + LOL + PLL_TVL) .
-Mode control input.
-Mode control input.
-Tuning Voltage Alarm. =1 If CAPTURE RANGE NEAR 10% OF EXTREME (~11ppm).
-Ground.
-Syncronized output.
-Ground.
-Stratum 3 TCXO output. (Non-synchronized).
-Ground.
-External Reference #2 Input. (8 KHz)
-Ground.
-Input. External Reference #1 Input. (8 KHz)
+5 Volt DC supply.
NOTES:
NOTES FOR TABLES 1-3
2.0 Holdover stability is the cumulative fractional frequency offset containing Initial Offset, Temperature, and Drift components as described by
Bellcore GR-1244-CORE 5.2.
3.0 Pull-in range is the minimum frequency deviation on the reference inputs to the timing module that can be overcome to pull itself into synchronization
with the reference.
4.0 After 100 seconds at stable room temperature.
5.0 Consult factory for other output frequencies.
www.DataSheet4U.com
6.0 Ref- GR1244-CORE 3.2.1 R3-1.
7.0 A ‘1’ level indicates unit is within the extreme 10% of its operating range tracking the reference (~11ppm). Consult factory for use as a reference
quilifier.
8.0 Add ‘-T2’ to model number.
9.0 Consult factory for power dissipation of -T2 (0 to +70 deg. C.) devices.
INT Specifications subject to change without notice.
DATA SHEET #: _T_M__0_0_7______ PAGE____5__ OF __6_____ REV:__0_2_____ DATE:___6_/_2_/_9_9____ © Copyright 1999 Connor-Winfield all rights reserved.

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet MSTM-S3.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MSTM-S3STRATUM 3 SIMPLIFIED CONTROL TIMING MODULESConnor-Winfield
Connor-Winfield

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar