DataSheet.es    


PDF N5161A Data sheet ( Hoja de datos )

Número de pieza N5161A
Descripción MXG ATE Analog Signal Generators
Fabricantes Agilent(Hewlett-Packard) 
Logotipo Agilent(Hewlett-Packard) Logotipo



Hay una vista previa y un enlace de descarga de N5161A (archivo pdf) en la parte inferior de esta página.


Total 22 Páginas

No Preview Available ! N5161A Hoja de datos, Descripción, Manual

Agilent N5181A MXG
and N5161A MXG ATE
Analog Signal Generators
Data Sheet Optimized for
performance and speed
• Fast switching speeds
• Simplified self-maintenance
• High output power
www.DataSheet4U.com

1 page




N5161A pdf
Accuracy
± aging rate
± temperature effects
± line voltage effects
Internal time base reference
oscillator aging rate
≤ ± 5 ppm/10 yrs, < ± 1 ppm/yr (nom) 1
Temperature effects
Line voltage effects
Reference output
Frequency
Amplitude
± 1 ppm (0 to 55 °C) (nom)
± 0.1 ppm (nom); 5% to –10% (nom)
10 MHz
≥ +4 dBm (nom) into 50 Ω load
External reference input
Input frequency
Lock range
Amplitude
Impedance
Waveform
Standard
Option 1ER
10 MHz
1 to 50 MHz (in multiples of 0.1 Hz)
± 1 ppm
> –3.5 to 20 dBm (nom)
50 Ω (nom)
Sine or square
Digital sweep modes
Operating modes
Sweep range
Dwell time
Number of points
Step change
Triggering
Step sweep (equally or logarithmically spaced
frequency steps)
List sweep (arbitrary list of frequency steps)
Can also simultaneously sweep amplitude.
See amplitude section
for more detail.
Within instrument frequency range
100 µs to 100 s
2 to 65535 (step sweep)
1 to 3201 (list sweep)
Linear or logarithmic
Free run, trigger key, external, timer, bus (GPIB, LAN, USB)
www.DataSheet4U.com
1. Aging rate is determined by design as a function of the TCXO and is not specified.
5

5 Page





N5161A arduino
Spectral Purity
www.DataSheet4U.com
User flatness correction
Number of points
3201
Number of tables
Dependent on available free memory in instrument;
10000 maximum
Entry modes
USB/LAN direct power meter control, LAN to GPIB and USB
to GPIB, remote bus and manual USB/GPIB power meter
control
Digital sweep modes
Operating modes
Step sweep (evenly spaced amplitude steps)
List sweep (arbitrary list of amplitude steps)
Can also simultaneously sweep frequency.
See frequency section for more detail.
Sweep range
Dwell time
Number of points
Step change
Triggering
Within instrument amplitude range
100 µs to 100 s
2 to 65535 (step sweep) 1 to 3201 (list sweep)
Linear
Free run, trigger key, external, timer, bus (GPIB, LAN, USB)
Single sideband phase noise [at 20 kHz offset]
500 MHz
1 GHz
2 GHz
≤ –126 dBc/Hz (typ)
≤ –121 dBc/Hz (typ)
≤ –115 dBc/Hz (typ)
3 GHz
4 GHz
6 GHz
≤ –110 dBc/Hz (typ)
≤ –109 dBc/Hz (typ)
≤ –104 dBc/Hz (typ)
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
-120
-130
-140
-150
-160
-170
1.E+01
1.E+02
Single sideband phase noise in CW mode
5.8 GHz
3.5 GHz
2.2 GHz
1.9 GHz
1 GHz
850 MHz
1.E+03
1.E+04
1.E+05
L(f) [dBc/Hz] vs. f[Hz]
1.E+06
1.E+07
1.E+08
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
-120
-130
-140
-150
-160
-170
1.E+01
Single sideband phase noise optimized signal-to-noise floor mode¹
5.8 GHz
3.5 GHz
2.2 GHz
1.9 GHz
1 GHz
850 MHz
1.E+02
1.E+03
1.E+04
1.E+05
L(f) [dBc/Hz] vs. f[Hz]
1.E+06
1.E+07
1.E+08
1. Signal-to-noise optimized mode will improve broadband noise floor. In this mode, other specifications
may not apply. Applies to instrument serial number prefix 4818xxxx or above.
11

11 Page







PáginasTotal 22 Páginas
PDF Descargar[ Datasheet N5161A.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
N5161AMXG ATE Analog Signal GeneratorsAgilent(Hewlett-Packard)
Agilent(Hewlett-Packard)

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices