Datasheet.kr   

E5092A PDF 데이터시트 : 부품 기능 및 핀배열

부품번호 E5092A
기능 ENA Network Analyzer
제조업체 Agilent(Hewlett-Packard)
로고 Agilent(Hewlett-Packard) 로고 



전체 30 페이지

		

No Preview Available !

E5092A 데이터시트, 핀배열, 회로
Agilent E5071C ENA Network Analyzer
• 9 kHz to 4.5/6.5/8.5 GHz
• 100 kHz to 4.5/6.5/8.5 GHz (with bias tees)
• 300 kHz to 14/20 GHz (with bias tees)
E5091A Multiport Test Set
E5092A Configurable Multiport Test Set
Data Sheet
www.DataSheet4U.com




E5092A pdf, 반도체, 판매, 대치품
Definitions
Specification (spec.):
Warranted performance. All specifications apply at 23 ºC (± 5 ºC), unless
otherwise stated, and 90 minutes after the instrument has been turned on.
Specifications include guard bands to account for the expected statistical
performance distribution, measurement uncertainties, and changes in
performance due to environmental conditions.
Supplemental information is intended to provide information that is helpful for
using the instrument but that is not guaranteed by the product warranty.
Typical (typ.):
Describes performance that will be met by a minimum of 80% of all products.
It is not guaranteed by the product warranty.
Supplemental performance data (SPD):
Supplemental performance data represents the value of a parameter that is
most likely to occur; the expected mean or average. It is not guaranteed by the
product warranty.
General characteristics:
A general, descriptive term that does not imply a level of performance.
Boundary Conditions
In this data sheet, boundary conditions are given for the specifications. For
example, system dynamic range is 98 dB with the following boundary conditions.
Option: 485
Frequency: 10 MHz
IF bandwidth: 3 kHz
If the same boundary conditions fall under more than one category in a table,
apply the best value.
www.DataSheet4U.com
4

4페이지










E5092A 전자부품, 판매, 대치품
Corrected system performance with calibration kit
Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485
Table 3. Corrected system performance with type-N device connectors,
85032F calibration kit
Network analyzer:
Calibration kit:
Calibration:
E5071C
85032F (Type-N, 50 Ω)
full 2-port
IF bandwidth = 10 Hz, no averaging applied to data, environmental temperature = 23 °C
(±5 °C ) with < 1 °C deviation from calibration temperature, isolation calibration performed
Description
Directivity
Source match
Load match
Reflection tracking
Transmission tracking
Specification (dB)
9 kHz to
300 kHz
300 kHz to
10 MHz
49 49
41 41
49 49
±0.011
±0.011
±0.027
±0.015
10 MHz to
3 GHz
46
40
46
±0.021
±0.018
3 GHz to
6 GHz
40
36
40
±0.032
±0.056
6 GHz to
8.5 GHz
38
35
37
±0.054
±0.088
Transmission uncertainty (specification)
Magnitude
10
9 KHz to 300 KHz
300 KHz to 10 MHz
10 MHz to 3 GHz
1 3 GHz to 6 GHz
6 GHz to 8.5 GHz
100 Phase
9 KHz to 300 KHz
300 KHz to 10 MHz
10 MHz to 3 GHz
3 GHz to 6 GHz
1 0 6 GHz to 8.5 GHz
0.1 1
0.01
10
S11 = S22 = 0; Cal power = -10 dBm ; Meas power = -10 dBm
0 –10 –20 –30 –40 –50 –60 –70 –80 –90
Transmission coefficient (dB)
Reflection uncertainty (specification)
Magnitude
0.05
0.04
9 KHz to 300 KHz, 300 KHz to 10 MHz
10 MHz to 3 GHz
3 GHz to 6 GHz
6 GHz to 8.5 GHz
www.DataSh0e.0e3 t4U.com
0.02
0.01
0
0
S21 = S12 = 0; Cal power = -10 dBm; Meas power = -10 dBm
0.2 0.4 0.6 0.8
Reflection coefficient (linear)
1
0.1
S11 = S22 = 0; Cal power = -10 dBm ; Meas power = -10 dBm
10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90
Transmission coefficient (dB)
Phase
10
8
6
9 KHz to 300 KHz, 300 KHz to 10 MHz
10 MHz to 3 GHz
3 GHz to 6 GHz
6 GHz to 8.5 GHz
4
2
S21 = S12 = 0; Cal power = -10 dBm; Meas power = -10 dBm
0
0 0.2 0.4 0.6 0.8 1
Reflection coefficient (linear)
7

7페이지



구       성총 30 페이지
다운로드[ E5092A.PDF 데이터시트 ]
구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

전력 반도체 판매 ( IGBT, TR 모듈, SCR, 다이오드 모듈 )

상호 : 아이지 인터내셔날

사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ]



링크공유

링크 :

관련 데이터시트

부품번호상세설명 및 기능제조사
E5092A

ENA Network Analyzer

Agilent(Hewlett-Packard)
Agilent(Hewlett-Packard)

DataSheet.kr    |   2020   |  연락처   |  링크모음   |   검색  |   사이트맵