부품번호 | E6833A 기능 |
|
|
기능 | Wireless Communications Test Set | ||
제조업체 | Agilent(Hewlett-Packard) | ||
로고 | |||
Agilent E6833A cdma2000/1xEV-DO
Calibration Application
For the E6601A Wireless Communications Test Set
Data Sheet
The next generation of mobile phone
manufacturing test.
E6601A/E6890A Features and
General Specifications
The Agilent E6601A is the new, one-box test set that expedites
mobile phone calibration. Combining industry-leading measure-
ment speed, selectable formats, flexible licensing, and an
integrated open Windows® XP PC, the E6601A helps you achieve
the lowest cost of test in mobile phone manufacturing.
The E6601A and its available technology-specific software
applications deliver industry leading measurement speed and
accuracy for your mobile phone test needs.
The Agilent E6833A cdma2000/1xEV-DO Calibration Application
is a non-signaling application optimized for cdma2000®/1xEV-DO
mobile phone calibration. The E6833A also provides a choice of
perpetual, transportable, or term licenses for maximizing asset
utilization and your cost per test.
The test set and its applications use emerging advancements such
as fast device tune features to deliver fast, high-quality calibration.
Because it’s Agilent, you can be confident—it operates using
trusted, proven measurement methodology that ensures measure-
ment integrity that is never compromised.
www.DataSheet4U.com
• CW, AM, FM, DSB-SC-SC source modulation
• RF analyzer
• Spectrum monitor
• Transmitter power measurement
• Power versus time measurement
• Frequency error measurement
• Optional IQ capture waveform sampling
• Internal OCXO timebase
• Built-in open Windows XP PC
• Run test programs with internal or external PC
• GPIB, USB, and LAN connectivity and control
E6833A Features
Source modulation
• CW, amplitude, frequency, IS-95, cdma2000, and 1xEV-DO
Power measurements
• Mean power
• Root-raised cosine power
Power measurements
• Channel power
• Dynamic power
• Fast device tune
Spectral measurements
• Tx spurious emissions
• Occupied bandwidth
• Spectrum monitor
Modulation quality measurements
• IS-95, cdma2000 RC1 rho
Occupied bandwidth
Dynamic Power Measurement
Measurement method
Input level range
Measurement accuracy
Measures the bandwidth that
contains 99.0% of the total
integrated power of the
transmitted signal centered on
the selected reverse channel
+5 to +28 dBm/1.23 MHz
±60 kHz for 99.0% total
integrated power
Tx spurious emissions
Measurement method
Input level range
Measurement offsets
Frequencies < 1000 MHz
Frequencies > 1000 MHz
Measurement bandwidth
Carrier
Offsets
Measurement accuracy
±885 kHz, ±1.25 MHz
±1.98 MHz
Residual noise floor
±885 kHz, ±1.25 MHz
±1.98 MHz offsets
Mobile pass/fail limits
Auto mode
Frequencies < 1000 MHz
Frequencies > 1000 MHz
Manual mode
Measures the active carrier
power in a 1.23 MHz bandwidth,
then measures the power in a
30 kHz bandwidth at two offsets
above and below the active
carrier and displays the ratio
of the offset powers to the
active carrier power in dBc
+0 to +30 dBm/1.23 MHz
±885 kHz, ±1.98 MHz
±1.25 MHz, ±1.98 MHz
1.23 MHz flat channel filter
30 kHz synchronously tuned,
five-pole filter with approximately
Gaussian shape
< ±0.35 dB, typically < ±0.15 dB
< ±0.6 dB, typically < ±0.25 dB
< –73 dBc/30 kHz BW
< –75 dBc/30 kHz BW
–42 dBc/30 kHz for
±885 kHz offsets
–54 dBc/30 kHz for
±1.98 MHz offsets
–42 dBc/30 kHz for
±1.25 MHz offsets
–50 dBc/30 kHz for
±1.98 MHz offsets
Settable from –10 to –65 dBc
with 0.01 dB resolution
Measurement method
Captures a user-defined trace
consisting of 5, 10, or 20 ms
duration power steps with
user-defined step size produced
by a test mode in the device
under test. Measures the total
power in each step period in a
1.23 MHz bandwidth centered
on the reverse channel center
frequency
Input level range
–61 to +28 dBm/1.23 MHz
Amplitude capture range
With 4 dB crest < ±2 dB of
expected power
Measurement accuracy1 (within +2 to –45 dB of expected power)
–61 to +28 dBm/1.23 MHz < ±0.7 dB, typically < ±0.2 dB
Measurement accuracy1 (within 45 dB of expected power with
< 48 hours warm-up before self alignment initiation)
–59 to +28 dBm/1.23 MHz < ±0.7 dB, typically < ±0.3 dB
–65 to < –59 dBm/1.23 MHz < ±0.8 dB, typically < ±05 dB
Measurement repeatability
Typically < ±0.05 dB for returning
to the same level and frequency
with no temperature change and
insignificant time change
Trigger setup
Sources external, fall, rise
Trigger
pulse
User specified
maximum power
Step size
Step duration
www.DataSheet4U.com
1. Additional accuracy error when using RF OUT ONLY port is < ±0.1 dB.
4
4페이지 | |||
구 성 | 총 6 페이지수 | ||
다운로드 | [ E6833A.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
E6833A | Wireless Communications Test Set | Agilent(Hewlett-Packard) |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |