DIESEL ENGINE-GENERATOR SET
300-XC6DT3
300 ekW / 60 Hz / Standby
260 ekW / 60 Hz / Prime
208 - 600V
System Ratings
Standby
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
Prime
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
wwwGTee.mDnepartRaatiSsoher eMeot4deUl*.c om
Connection
240V**
1
1.0
60
300
300
1250
490
572RSL4029
130°C/27°C
12 LEAD ZIG-ZAG
240V
1
1.0
60
260
260
1083
490
572RSL4029
105°C/40°C
12 LEAD ZIG-ZAG
208V**
3
0.8
60
300
375
1041
760
433CSL6216
130°C/27°C
12 LEAD LOW WYE
240V**
3
0.8
60
300
375
902
760
433CSL6216
130°C/27°C
12 LEAD HI DELTA
480V**
3
0.8
60
300
375
451
700
432CSL6212
130°C/27°C
12 LEAD HI WYE
208V
3
0.8
60
260
325
902
520
432CSL6212
105°C/40°C
12 LEAD LOW WYE
240V
3
0.8
60
260
325
782
520
432CSL6212
105°C/40°C
12 LEAD HI DELTA
480V
3
0.8
60
260
325
391
700
432CSL6212
105°C/40°C
12 LEAD HI WYE
* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration.
** UL2200 Offered
600V**
3
0.8
60
300
375
361
720
432PSL6246
125°C/40°C
4 LEAD WYE
600V
3
0.8
60
260
325
313
720
432PSL6246
105°C/40°C
4 LEAD WYE




300-XC6DT3 pdf, 반도체, 판매, 대치품
Weights and dimensions
4 / //  / 300-XC6DT3
Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design.
System Dimensions (L x W x H)
OPU
140 x 57 x 79.6 in (3,560 x 1,450 x 2,020 mm)
Weight (less tank)
5,916 lb (2,683 kg)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
Sound data
Unit Type
OPU w/Critical Grade Muffler (dBA)
Sound Attenuated Enclosure (dBA)
Measurements for sound data are taken at 23 ft (7 m).
Emissions data
Standby Full Load
95
87
Standby No Load
89
81
Prime Full Load
93.5
85.5
Prime No Load
89
81
Rating Definitions and conditions
NOx + NMHC
2.74
CO
0.56
PM
0.09
All units are in g/hp-hr and are EPA D2 cycle values.
Emission levels of the engine may vary as a function of ambi-
ent temperature, barometric pressure, humidity, fuel type and
quality, installation parameters, measuring instrumentation,
etc. The data provided are laboratory results from one engine
representing this rating. The data was obtained under cont-
rolled environmental conditions with calibrated instrumentation
traceable to the United States National Bureau of Standards
and in compliance with US EPA regulations found within 40 CFR
Part 89. The weighted cycle value from each engine is guaran-
teed to be below the US EPA Standards at the US EPA defined
conditions.
www.DataSheet4U.com
//  Ambient capability factor at 984 ft (300 m). Consult your
local MTU Onsite Energy Power Generation Distributor for
other altitudes.
//  Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload capa-
bility for this rating. Ratings are in accordance with
ISO-3046/1, BS 5514, AS 2789, and DIN 6271.
//  Prime power ratings apply to installations where utility power
is unavailable or unreliable. At varying load, the number of
generator set operating hours is unlimited. A 10% overload
capacity is available for one hour in twelve. Ratings are in
accordance with ISO-8528/1, overload power in accordance
with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For
limited running time and base load ratings, consult the
factory.
//  Deration Factor:
Altitude: 1% per 1,000 ft (305 m) above 600 ft (183 m).
Temperature: 1% per 10°F (5.5°C) above 77°F (25°C).
Materials and specifications subject to change without notice.
// Tognum Group Companies: Europe / Middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 /
Fax +49 7541 90 7084 / [email protected] // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore /
Phone + 65 6861 5922 / Fax + 65 6861 3615 / [email protected] // USA / Canada / Mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota
56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / [email protected] // Worldwide for HotModule / MTU Onsite Energy / 81663 Munich /
Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / [email protected] //www.mtu-online.com

4페이지












구       성 총 4 페이지수
다운로드[ 300-XC6DT3.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
300-XC6DT3

DIESEL ENGINE-GENERATOR SET

MTU Onsite Energy
MTU Onsite Energy

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵