Datasheet.kr   

400-XC6DT3 데이터시트 PDF




MTU Onsite Energy에서 제조한 전자 부품 400-XC6DT3은 전자 산업 및 응용 분야에서
광범위하게 사용되는 반도체 소자입니다.


PDF 형식의 400-XC6DT3 자료 제공

부품번호 400-XC6DT3 기능
기능 DIESEL ENGINE-GENERATOR SET
제조업체 MTU Onsite Energy
로고 MTU Onsite Energy 로고


400-XC6DT3 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.



전체 4 페이지수

미리보기를 사용할 수 없습니다

400-XC6DT3 데이터시트, 핀배열, 회로
A tognum Group Brand
DIESEL ENGINE-GENERATOR SET
400-XC6DT3
400 ekW / 60 Hz / Standby
340 ekW / 60 Hz / Prime
208 - 4160V
System Ratings
Standby
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
240V**
1
1.0
60
400
400
1667
700
573RSL4035
130°C/27°C
12 LEAD ZIG-ZAG
Prime
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
wwwGTee.mDnepartRaatiSsoher eMeot4deUl*.c om
Connection
240V
1
1.0
60
340
340
1417
700
573RSL4035
105°C/40°C
12 LEAD ZIG-ZAG
208V**
3
0.8
60
400
500
1388
240V**
3
0.8
60
400
500
1203
820
433CSL6220
130°C/27°C
12 LEAD LOW WYE
820
433CSL6220
130°C/27°C
12 LEAD HI DELTA
208V
3
0.8
60
340
425
1180
240V
3
0.8
60
340
425
1022
820
433CSL6220
105°C/40°C
12 LEAD LOW WYE
820
433CSL6220
105°C/40°C
12 LEAD HI DELTA
480V**
3
0.8
60
400
500
601
600V**
3
0.8
60
400
500
481
1100
433CSL6220
130°C/27°C
12 LEAD HI WYE
1100
433PSL6248
125°C/40°C
4 LEAD WYE
480V
3
0.8
60
340
425
511
600V
3
0.8
60
340
425
409
1100
433CSL6220
105°C/40°C
12 LEAD HI WYE
1100
433PSL6248
105°C/40°C
4 LEAD WYE
* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration.
** UL2200 Offered
4160V
3
0.8
60
400
500
69
1100
573FSM4352
130°C/27°C
6 LEAD WYE
4160V
3
0.8
60
340
425
59
1100
573FSM4352
105°C/40°C
6 LEAD WYE




400-XC6DT3 pdf, 반도체, 판매, 대치품
Weights and dimensions
4 / //  / 400-XC6DT3
Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design.
System Dimensions (L x W x H)
OPU
140 x 57 x 79.6 in (3,556 x 1,446 x 2,022 mm)
Weight (less tank)
6,396 lb (2,901 kg)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
Sound data
Unit Type
OPU w/Critical Grade Muffler (dBA)
Sound Attenuated Enclosure (dBA)
Measurements for sound data are taken at 23 ft (7 m).
Emissions data
Standby Full Load
96.5
88.5
Standby No Load
89
81
Prime Full Load
95
87
Prime No Load
89
81
Rating Definitions and conditions
NOx + NMHC
2.66
CO
0.98
PM
0.13
All units are in g/hp-hr and are EPA D2 cycle values.
Emission levels of the engine may vary as a function of ambi-
ent temperature, barometric pressure, humidity, fuel type and
quality, installation parameters, measuring instrumentation,
etc. The data provided are laboratory results from one engine
representing this rating. The data was obtained under cont-
rolled environmental conditions with calibrated instrumentation
traceable to the United States National Bureau of Standards
and in compliance with US EPA regulations found within 40 CFR
Part 89. The weighted cycle value from each engine is guaran-
teed to be below the US EPA Standards at the US EPA defined
conditions.
www.DataSheet4U.com
//  Ambient capability factor at 984 ft (300 m). Consult your
local MTU Onsite Energy Power Generation Distributor for
other altitudes.
//  Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload capa-
bility for this rating. Ratings are in accordance with
ISO-3046/1, BS 5514, AS 2789, and DIN 6271.
//  Prime power ratings apply to installations where utility power
is unavailable or unreliable. At varying load, the number of
generator set operating hours is unlimited. A 10% overload
capacity is available for one hour in twelve. Ratings are in
accordance with ISO-8528/1, overload power in accordance
with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For
limited running time and base load ratings, consult the
factory.
//  Deration Factor:
Altitude: 1% per 1,000 ft (305 m) above 600 ft (183 m).
Temperature: 1% per 10°F (5.5°C) above 77°F (25°C).
Materials and specifications subject to change without notice.
// Tognum Group Companies: Europe / Middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 /
Fax +49 7541 90 7084 / [email protected] // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore /
Phone + 65 6861 5922 / Fax + 65 6861 3615 / [email protected] // USA / Canada / Mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota
56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / [email protected] // Worldwide for HotModule / MTU Onsite Energy / 81663 Munich /
Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / [email protected] //www.mtu-online.com

4페이지












구       성 총 4 페이지수
다운로드[ 400-XC6DT3.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
400-XC6DT3

DIESEL ENGINE-GENERATOR SET

MTU Onsite Energy
MTU Onsite Energy

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵