Datasheet.kr   

900-XC6DT2 PDF 데이터시트 : 부품 기능 및 핀배열

부품번호 900-XC6DT2
기능 DIESEL ENGINE-GENERATOR SET
제조업체 MTU Onsite Energy
로고 MTU Onsite Energy 로고 



전체 4 페이지

		

No Preview Available !

900-XC6DT2 데이터시트, 핀배열, 회로
A tognum Group Brand
DIESEL ENGINE-GENERATOR SET
900-XC6DT2
900 ekW / 60 Hz / Standby
800 ekW / 60 Hz / Prime
208 - 4160V
System Ratings
Standby
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
Prime
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
wwwGTee.mDnepartRaatiSsoher eMeot4deUl*.c om
Connection
208V**
3
0.8
60
900
1125
3123
2600
741RSL4045
130°C/27°C
12 LEAD LOW WYE
208V
3
0.8
60
800
1000
2776
2600
741RSL4045
105°C/40°C
12 LEAD LOW WYE
240V**
3
0.8
60
900
1125
2706
2600
741RSL4045
130°C/27°C
12 LEAD HI DELTA
240V
3
0.8
60
800
1000
2406
2600
741RSL4045
105°C/40°C
12 LEAD HI DELTA
480V**
3
0.8
60
900
1125
1353
2600
574RSL4038
130°C/27°C
4 LEAD WYE
480V
3
0.8
60
800
1000
1203
2600
574RSL4037
105°C/40°C
12 LEAD HI WYE
600V**
3
0.8
60
900
1125
1083
2850
574RSS4280
125°C/40°C
4 LEAD WYE
600V
3
0.8
60
800
1000
962
2850
574RSS4280
105°C/40°C
4 LEAD WYE
* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration.
** UL2200 Offered
4160V
3
0.8
60
900
1125
156
1950
741FSM4360
130°C/27°C
6 LEAD WYE
4160V
3
0.8
60
800
1000
139
1950
741FSM4360
105°C/40°C
6 LEAD WYE




900-XC6DT2 pdf, 반도체, 판매, 대치품
Weights and dimensions
4 / //  / 900-XC6DT2
Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design.
System Dimensions (L x W x H)
OPU
190 x 68 x 101.6 in (4,830 x 1,730 x 2,480 mm)
Weight (less tank)
16,691 lb (7,571 kg)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
Sound data
Unit Type
OPU w/Critical Grade Muffler (dBA)
Sound Attenuated Enclosure (dBA)
Measurements for sound data are taken at 23 ft (7 m).
Emissions data
Standby Full Load
101
93
Standby No Load
94
86
Prime Full Load
99.5
91.5
Prime No Load
94
86
Rating Definitions and conditions
NOx + NMHC
5.5
CO
1.44
PM
0.131
All units are in g/hp-hr and are EPA D2 cycle values.
Emission levels of the engine may vary as a function of ambi-
ent temperature, barometric pressure, humidity, fuel type and
quality, installation parameters, measuring instrumentation,
etc. The data provided are laboratory results from one engine
representing this rating. The data was obtained under cont-
rolled environmental conditions with calibrated instrumentation
traceable to the United States National Bureau of Standards
and in compliance with US EPA regulations found within 40 CFR
Part 89. The weighted cycle value from each engine is guaran-
teed to be below the US EPA Standards at the US EPA defined
conditions.
www.DataSheet4U.com
Materials and specifications subject to change without notice.
//  Ambient capability factor at 984 ft (300 m). Consult your
local MTU Onsite Energy Power Generation Distributor for
other altitudes.
//  Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload capa-
bility for this rating. Ratings are in accordance with
ISO-3046/1, BS 5514, AS 2789, and DIN 6271.
//  Prime power ratings apply to installations where utility power
is unavailable or unreliable. At varying load, the number of
generator set operating hours is unlimited. A 10% overload
capacity is available for one hour in twelve. Ratings are in
accordance with ISO-8528/1, overload power in accordance
with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For
limited running time and base load ratings, consult the
factory.
//  Deration Factor:
Altitude: 1.8% per 1,640 ft (500 m) above 3,281 ft
(1,000 m)* at 104°F (40°C).
Temperature: 1.0% per 9°F (5°C) over 113°F (45°C) at
328 ft (100 m).
*Contact factory for deration above 8,202 ft (1,800 m).
// Tognum Group Companies: Europe / Middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 /
Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore /
Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // USA / Canada / Mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota
56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for HotModule / MTU Onsite Energy / 81663 Munich /
Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com

4페이지













구       성총 4 페이지
다운로드[ 900-XC6DT2.PDF 데이터시트 ]
구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

전력 반도체 판매 ( IGBT, TR 모듈, SCR, 다이오드 모듈 )

휴대전화 : 010-3582-2743


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877, [ 홈페이지 ]



링크공유

링크 :

관련 데이터시트

부품번호상세설명 및 기능제조사
900-XC6DT2

DIESEL ENGINE-GENERATOR SET

MTU Onsite Energy
MTU Onsite Energy

DataSheet.kr    |   2019   |  연락처   |  링크모음   |   검색  |   사이트맵