Isolated CAN Transceiver with Integrated
High Voltage, Bus-Side, Linear Regulator
ADM3052
FEATURES
GENERAL DESCRIPTION
5 kV rms isolated CAN transceiver
Integrated V+ linear regulator
Bus side powered by V+ and V
11 V to 25 V operation on V+
5 V or 3.3 V operation on VDD1
Complies with ISO 11898 standard
High speed data rates up to 1 Mbps
Short-circuit protection on bus pins
Integrated bus miswire protection
Unpowered nodes do not disturb the bus
110 or more nodes on the bus
Thermal shutdown protection
High common-mode transient immunity: >25 kV/μs
Safety and regulatory approvals
UL recognition (pending)
5000 VRMS for 1 minute per UL 1577
VDE Certificates of Conformity (pending)
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
VIORM = 846 V peak
Industrial operating temperature range: −40°C to +85°C
Wide body, 16-lead SOIC package
The ADM3052 is an isolated controller area network (CAN)
physical layer transceiver with a V+ integrated linear regulator.
The ADM3052 complies with the ISO 11898 standard.
The device employs Analog Devices, Inc., iCoupler® technology
to combine a 3-channel isolator, a CAN transceiver, and a linear
regulator into a single package. The power is isolated between a
single 3.3 V or 5 V supply on VDD1, the logic side, and a single
24 V supply provided on V+, the bus side.
The ADM3052 creates an isolated interface between the CAN
protocol controller and the physical layer bus. It is capable of
running at data rates up to 1 Mbps.
The device has integrated miswire protection on the bus pins,
V+, V, CANH, and CANL.
The device has current-limiting and thermal shutdown features
to protect against output short circuits and situations where the
bus may be shorted to ground or power terminals. The part
is fully specified over the industrial temperature range and is
available in a 16-lead, wide-body SOIC package.
APPLICATIONS
CAN data buses
Industrial field networks
DeviceNet applications
FUNCTIONAL BLOCK DIAGRAM
VDD1
CINT
ISOLATION
BARRIER
LINEAR
REGULATOR
V+R
VDD2
V+SENSE
TxD
DECODE
ENCODE
ENCODE
BUS
V+SENSE
DECODE
TxD
PROTECTION
DRIVER
VDD2
V+
RxD
DECODE
DIGITAL ISOLATION
ENCODE
GND2
ADM3052
RxD
VREF
RECEIVER
REFERENCE
VOLTAGE
CAN TRANSCEIVER
GND2
CANH
CANL
VREF
V
GND1
LOGIC SIDE
BUS SIDE
Figure 1.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarksandregisteredtrademarksarethepropertyoftheirrespectiveowners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2011 Analog Devices, Inc. All rights reserved.
Datasheet pdf - http://www.DataSheet4U.net/

1 page




ADM3052 pdf
www.DataSheet.co.kr
ADM3052
VDE 0884 INSULATION CHARACTERISTICS (PENDING)
This isolator is suitable for reinforced electrical isolation within the safety limit data. Maintenance of the safety data must be ensured by
means of protective circuits.
Table 5.
Description
CLASSIFICATIONS
Installation Classification per DIN VDE 0110 for Rated
Mains Voltage
≤150 V rms
≤300 V rms
≤400 V rms
Climatic Classification
Pollution Degree
VOLTAGE
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
After Environmental Tests, Subgroup 1
After Input and/or Safety Test,
Subgroup 2/Subgroup 3
Highest Allowable Overvoltage
SAFETY-LIMITING VALUES
Case Temperature
Input Current
Output Current
Insulation Resistance at TS
Test Conditions
DIN VDE 0110
VIORM × 1.875 = VPR, 100% production tested,
tm = 1 sec, partial discharge < 5 pC
VIORM × 1.6 = VPR, tm = 60 sec,
partial discharge < 5 pC
VIORM × 1.2 = VPR, tm = 60 sec,
partial discharge < 5 pC
Symbol
VIORM
VPR
VPR
VTR
TS
IS, INPUT
IS, OUTPUT
RS
Characteristic
I to IV
I to III
I to II
40/85/21
2
846
1590
1357
1018
6000
150
265
335
>109
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω
Rev. 0 | Page 5 of 20
Datasheet pdf - http://www.DataSheet4U.n

5 Page





ADM3052 arduino
www.DataSheet.co.kr
680
VDD1 = 3.3V
670
660
VDD1 = 5V
650
640
630
620
610
600
–40 –15
10
35
60
85
TEMPERATURE (°C)
Figure 21. Disable Time, V+ Low to V+SENSE High vs. Temperature
ADM3052
8.56
8.54
VDD1 = 3.3V
VDD1 = 5V
8.52
8.50
8.48
8.46
8.44
8.42
8.40
–40 –15
10
35
60
85
TEMPERATURE (°C)
Figure 22. Bus Voltage Sense Threshold Voltage High to Low vs. Temperature
Rev. 0 | Page 11 of 20
Datasheet pdf - http://www.DataSheet4U.net/

11 Page







PáginasTotal 20 Páginas
PDF Descargar[ Datasheet ADM3052.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
ADM3051High Speed Industrial CAN TransceiverAnalog Devices
Analog Devices
ADM3052Isolated CAN TransceiverAnalog Devices
Analog Devices
ADM3053Signal and Power Isolated CAN TransceiverAnalog Devices
Analog Devices
ADM30545 kV rms Signal Isolated High Speed CAN TransceiverAnalog Devices
Analog Devices

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar