부품번호 | VF5520 기능 |
|
|
기능 | 5 Port Pilot Operated Solenoid Valve Rubber Seal | ||
제조업체 | SMC | ||
로고 | |||
전체 30 페이지수
1
5 Port Pilot Operated Solenoid Valve
Rubber Seal
Series VF1000/3000/5000
Large flow capacity
Yet compact size.
Low power consumption
1.8 W (DC)
Exhausting equipment for pilot valve not required.
Common exhaust port for main and pilot valve (VF1000/3000)
www.DataSheet.net/
VF5000
C: 12 dm3/(s·bar)
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
32 mm width
VF3000
C: 3.1 dm3/(s·bar)
VF1000 {4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
C: 0.53 dm3/(s·bar) 26.4 mm width
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
26.4 mm width
VK
VZ
VF
VFR
VP4
VZS
VFS
VS4
VQ7
EVS
VFN
3-4-1
Datasheet pdf - http://www.DataSheet4U.co.kr/
Series VF1000/3000/5000
Port Symbol
Caution
VF1000
Supply
P
Cylinder A, B
EXH
outlet
EA, EB
VF3000
P (SUP)
A (CYL2)
B (CYL1)
R1 (EXH2)
R2 (EXH1)
VF5000
P
A, B
R1, R2
2. Detaching
To detach a socket from a connector,
pull out the lead wire while pressing the
socket’s hook with a stick having a thin
tip (approx. 1 mm). If the socket will be
used again, first spread the hook
outward.
Connector
Lead wire
JIS
symbol
Single
solenoid
1: P 4: A
2: B 5: R1
3: R2
1: P (SUP)
2: B (CYL.1)
3: R2 (EXH.1)
4: A (CYL.2)
5: R1 (EXH.2)
1: P
2: B
3: R2
4: A
5: R1
Attaching and Detaching Connectors
1. To attach a connector, hold the lever
and connector unit between your
fingers and insert straight onto the pins
of the solenoid valve so that the lever’s
pawl is pushed into the groove and
locks.
2. To detach a connector, remove the pawl
from the groove by pushing the lever
downward with your thumb, and pull the
connector straight out.
Type L
Groove
Pin
Cover
Connector
Pin
DC indicator
Lever
DC coil
Black
+ Red, – Black
Red
Lead wire
Socket DXT170-71-1
Type M
Cover
Crimping the Lead Wire and Socket
Peel 3.2 to 3.7 mm of the tip of lead wire,
enter the core wires neatly into a socket
and crimp it with a special crimp tool. Be
careful so that the cover of lead wire does
not enter into the crimping part.
Core wire
( )Socket crimping area
Crimping
area Core wire
Lead wire
0.2 to 0.33 mm2
Max. cover diameter
: ø1.7 mm
Hook
Insulation
Attaching and Detaching Lead Wires with Sockets
1. Attaching
Insert the sockets into the square holes
of the connector (with + and –
indication) and, continue to push the
sockets all the way in until the lock by
hooking into the seats in the connector.
(When they are pushed in, their hooks
open and they are locked
automatically.) Then confirm that they
are locked by pulling lightly on the lead
wires.
Socket Hook
Plug Connector Lead Wire Length
Standard length is 300 mm, but the
following lengths are also available.
How to Order Connector Assembly
DXT170 80 A
Lead wire color
Lead wire length
Symbol
Lead wire
with socket
Note
Nil
Socket only Without lead
(2 pcs.)
wire
Lead wire
Symbol length
L (mm)
Nil 300
6 600
1 Blue (2) For 100 VAC 10 1000
2 Red (2) For 200 VAC 15 1500
3 Gray (2) Another VAC 20 2000
4 Red: +, Black: – For DC 25 2500
30 3000
How to Order
Include the connector assembly part number
together with the part numberwww.DataSheet.net/ for the plug
connector's solenoid valve without connector.
(Example) 2000 mm lead wire length.
VF3230-5M0-02··········· 3 pcs.
DXT170-80-4A-20········6 pcs.
Mounting of Solenoid Valve and Pilot
Install so that there is no slippage of a
gasket, nor deformation, then tighten with
the following tightening torque.
Model
Pilot valve
Series VF1000
Series VF3000
Series VF5000
Tightening torque
0.6 N·m
1.4 N·m
1.4 N·m
1.4 N·m
Mounting Screw, Manifold Gasket
Model
VF130
VF133
VF330
VF333
VF340
VF343
VF350
VF520
VF544
Mounting screw
Round head
combination screw
DXT031-44-1
M4 x 39.5
With washer
Hexagon socket
head screw
AXT620-32-1
M4 x 48
With washer
Gasket
DXT144-12
DXT155-25-1
DXT031-30-2
DXT156-9-1
DXT156-9-2
How to Calculate the Flow Rate
For obtaining the flow rate, refer to page 3-1-10.
3-4-4
4
Datasheet pdf - http://www.DataSheet4U.co.kr/
4페이지 2 Position Single Solenoid
Grommet:
VF1120-G-
M5
01
VF10005 Port Pilot Operated Solenoid Valve
Rubber Seal Series
7
Grommet terminal: VF1120-E-M015
(Mounting hole)
(PE port)
≅300 (Lead wire length)
Manual
override
(Non-locking)
Applicable cable O.D.
ø2.3 to ø2.8
Manual override
(Non-locking)
M5 x 0.8, Rc 1/8
(P port)
(EA, EB port)
Bracket
2-M5 x 0.8, Rc 1/8
(A, B port)
2-M4 x 0.7 depth 5
(Mounting screw)
(EA, EB port)
Bracket
3-M5 x 0.8, Rc 1/8
(P, A, B port)
2-M4 x 0.7 depth 4
(Mounting screw)
Conduit terminal: VF1120-T-M015
Applicable cable O.D.
ø6 to ø8
( ): M5 x 0.8
: With light/surge voltage suppressor
DIN
terminal:
VF1120-D-
M5
01
VF1120-Y-
M5
01
www.DataSheet.net/
Applicable
cable O.D.
Y: ø4.5 to ø7
D: ø6 to ø8
VK
VZ
VF
VFR
VP4
VZS
VFS
VS4
VQ7
EVS
VFN
Manual override
(Non-locking)
Manual
override
(Non-locking)
(EA, EB port)
Bracket
3-M5 x 0.8, Rc 1/8
(P, A, B port)
(EA, EB port)
Bracket
3-M5 x 0.8, Rc 1/8
(P, A, B port)
( ): M5 x 0.8
: With light/surge voltage suppressor
( ): M5 x 0.8
: With light/surge voltage suppressor
3-4-7
Datasheet pdf - http://www.DataSheet4U.co.kr/
7페이지 | |||
구 성 | 총 30 페이지수 | ||
다운로드 | [ VF5520.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
VF5520 | 5 Port Pilot Operated Solenoid Valve Rubber Seal | SMC |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |