DataSheet.es    


PDF S8VK Data sheet ( Hoja de datos )

Número de pieza S8VK
Descripción POWER SUPPLIES
Fabricantes Omron 
Logotipo Omron Logotipo



Hay una vista previa y un enlace de descarga de S8VK (archivo pdf) en la parte inferior de esta página.


Total 14 Páginas

No Preview Available ! S8VK Hoja de datos, Descripción, Manual

S8VK POWER SUPPLIES
Reliable and easy operation – worldwide
http://www.DataSheet4U.net/
» The most compact class on the market
» Resistant in tough environments
» Easy and fast installation
datasheet pdf - http://www.DataSheet4U.net/

1 page




S8VK pdf
Easy and fast installation
Making your life easier
Simply click onto a standard DIN rail using one hand to
mount in a flash. Effortless and time saving! In addition, the
S8VK features a double set of DC output terminals (three for
the negative terminal), which means you also spend less
time and effort on wiring.
http://www.DataSheet4U.net/
5
Long-life guaranteed
Designed to international safety standards for global markets, the S8VK even has
approvals for marine applications and carries an across-the-board, warranty on all models
no matter which country your machine is exported to! Because of high MTBF figures, your
S8VK will keep running in stable condition for a long term.
datasheet pdf - http://www.DataSheet4U.net/

5 Page





S8VK arduino
S8VK
Series line-up
Specifications
S8VK-G Series
Derating Curve
15, 30, 240 W (S8VK-G015
120
100
0
60
, S8VK-G030
A
B
, S8VK-G240
40
20
0
−40 −25 −10 0 10 20 30 40 50 60 70 80
Ambient temperature (°C)
Note: 1. At less than 90 VAC, the derating is 2.5%/V
2. For a DC power input, reduce the load given in the above
derating curve by multiplying the following coefficients.
S8VK-G015 : 1.0
S8VK-G030 : 0.9
S8VK-G240 : 0.8
3. See “-40°C Operation Guarantee Condition”
A. Standard mounting
60°C and over: the derating is 2.5%/°C
B. Face-up mounting / Side mounting (15W only)
50°C and over: the derating is 2.5%/°C
60 W (S8VK-G060
120
100
80
60
)
A
B
40
20
0
−40 −25 −10 0 10 20 30 40 50 60 70 80
$PELHQWWHPSHUDWXUH ƒ&
Note: 1. At less than 90 VAC, the derating is 2.5%/V
2. For a DC power input, reduce the load given in the above
derating curve by multiplying the following coefficients.
S8VK-G060 : 0.9
3. See “-40°C Operation Guarantee Condition”
A. Standard mounting
60°C and over: the derating is 2.5%/°C
B. Face-up mounting
40°C and over: the derating is 1.67%/°C
)
120 W (S8VK-G12024)
120
100
80
60
A
B
40
20
0
−40 −25 −10 0 10 20 30 40 50 60 70 80
Ambient temperature (°C)
Note: 1. At less than 90 VAC, the derating is 2.5%/V
2. For a DC power input, reduce the load given in the above
derating curve by multiplying the following coefficients.
S8VK-G12024: 0.9
3. See “-40°C Operation Guarantee Condition”
A. Standard mounting
60°C and over: the derating is 3.5%/°C
B. Face-up mounting
40°C and over: the derating is 1.67%/°C
480 W (S8VK-G480
120
100
80
60
)
A
B
40
20http://www.DataSheet4U.net/
0
−40 −25 −10 0 10 20 30 40 50 60 70 80
$PELHQWWHPSHUDWXUH ƒ&
Note: 1. At less than 90 VAC, the derating is 2.5%/V
2. For a DC power input, reduce the load given in the above
derating curve by multiplying the following coefficients.
S8VK-G480 : 0.8
3. See “-40°C Operation Guarantee Condition”
A. Standard mounting
60°C and over: the derating is 2.5%/°C
B. Face-up mounting
30°C and over: the derating is 1.75%/°C
–40°C Operation Guarantee Condition
The unit can start up and operate normally at –40°C, but the following criteria will be inferior to the values of datasheet. Please consider these influences.
15 W
5V
15 W
12 V
15 W
24 V
30 W
5V
30 W
12 V
30 W
24 V
60 W
12 V
60 W
24 V
120 W
24 V
240 W
24 V
240 W
48 V
Ripple (Typ.)
Ripple (Max.)
Start up time (Typ.)
Hold time (Typ.)
230 VAC input 280 mV
230 VAC input 830 mV
230 VAC input 420 ms
230 VAC input 88 ms
170 mV
450 mV
440 ms
110 ms
100 mV
220 mV
490 ms
109 ms
110 mV
240 mV
410 ms
137 ms
330 mV
630 mV
440 ms
112 ms
180 mV
290 mV
480 ms
114 ms
200 mV
480 mV
420 ms
124 ms
420 mV
430 mV
490 ms
118 ms
440 mV
450 mV
760 ms
20 ms
840 mV
1030 mV
230 ms
35 ms
1220 mV
1320 mV
280 ms
37 ms
480 W
24 V
460 mV
670 mV
260 ms
39 ms
480 W
48 V
580 mV
870 mV
260 ms
41 ms
Power Boost Function
For All Models
[A]
Power Boost is a function that can output the temporary repeated
Note: Boost current conditions
boost current larger than the rated current.
However, it should meet the following four Boost current conditions.
1. Time that the boost current flows: t1
U t1 10 s
U Ip Rated boost current
U la ve Rated current
2. The maximum value of the boost current: lp
3. The average output current: lave
4. The time ratio of the boost current flow: Duty
D uty=
t1
t1 + t2
× 100 [ %] 30 %
t1 t2
Ip: Boost current
Rated current
lave: Average current
U Do not allow the boost current to continue for more than 10 seconds. Also, do not let the duty cycle the exceed boost current conditions.These conditions may damage the Power supply.
U Ensure that the average current of one cycle of the boost current does not exceed the rated output current. This may damage the Power Supply.
U Lessen the load of the boost load current by adjusting the ambient temperature and the mounting direction.
11
datasheet pdf - http://www.DataSheet4U.net/

11 Page







PáginasTotal 14 Páginas
PDF Descargar[ Datasheet S8VK.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
S8VKPOWER SUPPLIESOmron
Omron
S8VK-GSwitch Mode Power SupplyOmron
Omron
S8VK-G01505Switch Mode Power SupplyOmron
Omron
S8VK-G01512Switch Mode Power SupplyOmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar