T4N320 pdf, 반도체, 판매, 대치품
Tmax and Isomax
Power distribution circuit-breakers
General characteristics
The ABB family of moulded case circuit-breakers - Tmax and Isomax - is divided into different, perfectly
integrated, ranges (Tmax T1B 1p, T1, T2, T3, T4, T5 and Isomax S6 and S7), able to cover a range of service
currents from 1 to 1600 A.
The power distribution circuit-breakers are available in the fixed, plug-in or withdrawable, three-pole and
four-pole versions.
The Tmax T1 circuit-breaker is also available in the single pole
Tmax T1B 1p version, with breaking capacities of 25 kA at 220/230 V AC.
Interchangeability of the releases
The Tmax T4 and T5 circuit-breakers can be fitted either with thermomagnetic, magnetic only or electronic
releases, which are all interchangeable with each other. In fact, thanks to the simplicity of their installation,
the type of release can be replaced rapidly even by the end user, according to their requirements and needs:
in this case, correct assembly remains the responsibility of the user himself. All this means increasing the
flexibility of use of the circuit-breakers, with considerable savings thanks to the better rationalization of
stock management.
Conformity with Standards
The moulded-case circuit-breakers and their accessories conform to the IEC 60947-2 international
Standards and comply with the EC “Low Voltage Directives (LVD) no. 73/ 23 EEC” and “Electromagnetic
compatibility Directives (EMC) no. 89/336 EEC”.
ABB’s Quality System conforms to the ISO 9001 International Standard and to the equivalent European
EN ISO 9001 and Italian UNI EN ISO 9001 Standards. The certifying Body is the Italian Shipping Register
(RINA - QUACER): ABB has reached its third qualification confirmation. The ABB Test Room is accredited
by SINAL.
The apparatus conforms to the prescriptions of the on-board installations and approvals by the major
Shipping Registers are in progress.
ABB
7/19
1SDC007200C0201
Free Datasheet http://www.datasheet4u.com/

4페이지










T4N320 전자부품, 판매, 대치품
7/22
1SDC007200C0201
Tmax and Isomax
Power distribution circuit-breakers
Ordering details - Reading information
Abbreviations used to describe the apparatus
Type of connection terminals:
F = Front
terminals
EF =
Front
extended
terminals
FC CuAl =
Front
terminals
for Cu/Al
cables
MC =
Multi-
cable
terminals
RC =
Rear
terminals
for cables
FC CuAl =
Front
terminals for
Cu/Al cables
(housed
externally)
HR for
RC221/222 =
Rear flat
horizontal
terminals
ES =
Front
extended
spread
terminals
R=
Threaded
rear
terminals
(Isomax)
HR =
Rear flat
horizontal
terminals
FC Cu =
Front
terminals
for copper
cables
R=
Rear
terminals
(Tmax)
VR =
Rear flat
vertical
terminals
Type of currents:
I3
Magnetic trip
current [A]
Iu Rated uninterrupted
current of the
circuit-breaker [A]
In Rated current of the
protection release [A]
Icu Rated ultimate
short-circuit breaking
capacity [A]
Icw Rated short-time
withstand current
N= 50%
N= 100%
Protection of the
neutral at 50% or at
100% of that of the
phases [A]
Type of protection releases:
TMF
= Thermomagnetic
release with fixed
thermal and
magnetic threshold
TMD
= Thermomagnetic
release with
adjustable thermal
and fixed magnetic
threshold
TMA
TMG
= Thermomagnetic
release with
adjustable thermal
and magnetic
threshold
= Thermomagnetic
release for
generator
protection
MF = Fixed magnetic
only releases
MA = Adjustable magnetic
only releases
PR22_ = Electronic releases
(Tmax)
PR12_ = Electronic releases
(Isomax)
Electronic releases
Tmax PR221DS = electronic protection release;
functions I, LS/I
PR222DS = electronic protection release;
functions LSI, LSIG; available also
in the /PD version with dialogue
functions (Modbus)
PR222MP = electronic protection release for motor
protection; functions LRIU
Isomax PR211/P =
PR212/P =
electronic protection release;
functions I, LI
electronic protection release;
functions LSI, LSIG
PR212/MP = electronic protection release for
motor protection; functions LRIU
ABB
Free Datasheet http://www.datasheet4u.com/

7페이지


구       성 총 40 페이지수
다운로드[ T4N320.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
T4N320

Moulded case circuit-breakers

ABB
ABB

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵