Configuring Manual Edition 04/2007
SINAMICS S120 Drive Technology 1FT7 Synchronous Motors
1FT7 synchronous motors
SINAMICS S120
sinamics
s
Free Datasheet http://www.Datasheet4U.com
Safety Guidelines
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
Danger
indicates that death or severe personal injury will result if proper precautions are not taken.
Warning
indicates that death or severe personal injury may result if proper precautions are not taken.
Caution
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
Caution
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
Notice
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning and
operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes
in this documentation qualified persons are defined as persons who are authorized to commission, ground and
label devices, systems and circuits in accordance with established safety practices and standards.
Prescribed Usage
Note the following:
Warning
This device may only be used for the applications described in the catalog or the technical description and only
in connection with devices or components from other manufacturers which have been approved or
recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage,
positioning and assembly as well as careful operation and maintenance.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights of the
owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Automation and Drives
Postfach 48 48
90437 NÜRNBERG
GERMANY
6SN1197-0AD13-0BP0
Ⓟ 04/2007
Copyright © Siemens AG 2007.
Technical data subject to change
Free Datasheet http://www.Datasheet4U.com
4페이지 Preface
Disposal
Motors must be disposed of carefully taking into account domestic and local regulations in
the normal recycling process or by returning to the manufacturer.
The following must be taken into account when disposing of the motor:
● Oil according to the regulations for disposing of old oil
● Not mixed with solvents, cold cleaning agents of remains of paint
● Components that are to be recycled should be separated according to:
– Electronics waste (e.g. sensor electronics, sensor modules)
– Iron to be recycled
– Aluminum
– Non-ferrous metal (gearwheels, motor windings)
Danger and warning information
Danger
Start-up/commissioning is absolutely prohibited until it has been completely ensured that
the machine, in which the components described here are to be installed, is in full
compliance with the specifications of Directive 98/37/EC.
Only appropriately qualified personnel may commission/start-up the SINAMICS units and
the motors.
This personnel must carefully observe the technical customer documentation associated
with this product and be knowledgeable about and carefully observe the danger and
warning information.
Operational electrical equipment and motors have parts and components which are at
hazardous voltage levels.
When the machine or system is operated, hazardous axis movements can occur.
All of the work carried-out on the electrical machine or system must be carried-out with it in
a no-voltage condition.
SINAMICS units are generally designed for operation on low-resistance, grounded power
supply networks (TN systems). For additional information please refer to the appropriate
documentation for the drive converter systems.
Warning
The successful and safe operation of this equipment and motors is dependent on
professional transport, storage, installation and mounting as well as careful operator
control, service and maintenance.
For special versions of the drive units and motors, information and data in the catalogs and
quotations additionally apply.
In addition to the danger and warning notices in the technical customer documentation
supplied, the applicable national, local and plant-specific regulations and requirements
must be carefully taken into account.
1FT7 Synchronous Motors
Configuration Manual, (PFT7S), 04/2007, 6SN1197-0AD13-0BP0
7
Free Datasheet http://www.Datasheet4U.com
7페이지 | |||
구 성 | 총 30 페이지수 | ||
다운로드 | [ 1FT7044.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
1FT7044 | synchronous motors | Siemens |
1FT7044 | Servomotors | Siemens |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |