부품번호 ADP5111 기능
기능 Pressure sensor
제조업체 Panasonic
로고 Panasonic 로고


ADP5111 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 7 페이지수

미리보기를 사용할 수 없습니다

ADP5111 데이터시트, 핀배열, 회로
PS-A (ADP5)
Pressure sensor
Built-in amplifier and
compensating circuit
PS-A PRESSURE
SENSOR
<Low pressure type>
RoHS compliant
FEATURES
1. Contains built-in amplification and
temperature compensation circuit.
Circuit design and adjustment of
characteristics are not required by
users.
2. High-level precision and high
reliability realized.
• Overall accuracy is ±1.25% FS
(Standard type)
•O verall accuracy is ±4% FS
(Economy type)
•O verall accuracy is ±2.5% FS
(Low pressure type)
3. Compact pressure sensor unit that
saves space.
Same size and as previous PS pressure
sensor.
•F ootprint 7.0 mm (W) x 7.2 mm (D)
• 10.4 mm (W) x 10.4 mm (D)
(Low pressure type)
TYPICAL APPLICATIONS
(Please evaluate under actual conditions
before using.)
• Industrial use (pressure switches
and pneumatic devices, etc.)
• Medical use (blood pressure
monitors, compressed air pressure
measurement, air beds, etc.)
• Other pneumatically operated
pressure devices
Low pressure type
1. Water level detection for household
appliances
Washing machines and dishwashers.
2. Air pressure control
Clean rooms and separate rooms for
smokers.
3. Medical applications
Respiratory pressure measuring
instrument, etc.
ORDERING INFORMATION
<Terminal profile>
1: DIP terminal
ADP5 1
<Rated pressure>
0: ±100 kPa
1: –100 kPa
2: 25 kPa
3: 50 kPa
4: 100 kPa
5: 200 kPa
6: 500 kPa
7: 1,000 kPa
A: 40 kPa
B6: 6 kPa (Low pressure type)
<Pressure inlet hole>
0: length 3 mm, diameter 3 mm
1: length 5 mm, diameter 3 mm
2: length 13.5 mm, diameter 5.45 mm
<Type>
Nil: Standard type (with glass base)
Low pressure type
1: Economy type (without glass base)
Note: Some part numbers may not be available depending on the combination.
Please refer to the Table of Product Types on the next page.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB244E 201208-T
http://www.Datasheet4U.com




ADP5111 pdf, 반도체, 판매, 대치품
2. Low pressure type
1. Output voltage
ADP51B61
Drive voltage: 5V
Temperature: 25°C 77°F
Applied pressure: 0 to 6kPa
5.0
2. THB (high temperature high humidity bias test)
ADP51B61
Within 85°C 185°F and 85% RH
5 V applied between No. 2 (Vdd) and No. 3 (GND)
Applied pressure: 0kPa
1.00
4.5
PS-A (ADP5)
4.0 0.80
4.3
3.0 0.60
4.1
2.0 0.40
3.9
1.0 0.20
3.7
0.0
0.0
3.0
Applied pressure, kPa
6.0
0.00
intial
100h
3. Ambient temperature characteristics
Ambient temperature: 25°C 77°F 0°C 32°F 10°C 50°F 60°C 140°F 70°C 158°F
500h
1.00
4.50
3.5
intial
100h
500h
4. Shock test
ADP51B61
Shock applied:
981 m/s2 3 times in x, y and z directions
Applied pressure: 0kPa
1.00
0.80
4.30
0.80
0.60
4.10
0.60
0.40
3.90
0.40
0.20
3.70
0.20
0.00
25
77
0 10 60
32 50 140
Temperature, °C °F
70
158
4.50
3.50
25
77
0 10 60
32 50 140
Temperature, °C °F
70
158
0.00
intial
5. Vibration test
ADP51B61
Vibration applied: 10 to 55 Hz, amplitude: 1.5mm, x, y and z directions, 2 hrs each
Applied pressure: 0kPa
1.00
4.50
after test
4.30
0.80
4.30
4.10
0.60
4.10
3.90
0.40
3.90
3.70
0.20
3.70
3.50
intial
after test
6. Temperature/humidity cycle test
ADP51B61
Exposed to 10 cycles in the tempear ture and humidity
conditions given below.
Applied pressure: 0kPa
Temp. 65°C 149°F
25°C
77°F
2.5h
Time
3h
ⅪⅪⅪ
95% RH
1 cycle (24h)
65°C
149°F
10°C
14°F
2.5h 2.5h 3h 2.5h 1.5h 3.5h
25°C
77°F
3h
0% RH
0.00
intial
1.00
0.80
0.60
0.40
0.20
after test
3.50
intial
4.50
4.30
4.10
3.90
3.70
after test
ASCTB244E 201208-T
0.00
intial
10cyc
3.50
intial
10cyc
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/

4페이지










ADP5111 전자부품, 판매, 대치품
PS-A (ADP5)
NOTES
1. Mounting
Use lands on the printed-circuit boards to
which the sensor can be securely fixed.
2. Soldering
Due to its small size, the thermal capacity
of the pressure sensor DIP type is low.
Therefore, take steps to minimize the
effects of external heat.
Damage and changes to characteristics
may occur due to heat deformation.
Use a non-corrosive resin type of flux.
Since the pressure sensor DIP type is
exposed to the atmosphere, do not allow
flux to enter inside.
1) Manual soldering
• Set the soldering tip from 260 to 300°C
500 to 572°F (30W), and solder for no
more than 5 seconds.
• Please note that output may change if
the pressure is applied on the terminals
when the soldering.
• Thoroughly clean the soldering iron.
2) DIP soldering (DIP terminal type)
• Please keep the DIP solder bath
temperature no higher than 260°C 500°F.
When soldering, heat should be applied
no longer than five seconds.
• When mounting onto a PCB of low
thermal capacity, please avoid DIP
soldering as this may cause heat
deformity.
3) Solder reworking
• Finish reworking in one operation.
• For reworking of the solder bridge, use
a soldering iron with a flat tip. Please do
not add more flux when reworking.
• Please use a soldering iron that is
below the temperature given in the
specifications in order to maintain the
correct temperature at the tip of the
soldering iron.
4) Too much force on the terminals will
cause deformation and loss in
effectiveness of the solder. Therefore,
please avoid dropping and careless
handling of the product.
5) Please control warping of the PCB
within 0.05 mm of the sensor width.
6) When cut folding the PCB after
mounting the sensor, take measures to
prevent stress to the soldered parts.
7) The sensor terminals are designed to
be exposed, so contact of the terminals
with metal shards and the like will cause
output errors. Therefore, please be
careful and prevent things such as metal
shards and hands from contacting the
terminals.
8) To prevent degradation of the PCB
insulation after soldering, please be
careful not to get chemicals on the
sensor when coating.
9) Please consult us regarding the use of
lead-free solder.
3. Connections
1) Please perform connections correctly
in accordance with the terminal
connection diagram. In particular, be
careful not to reverse wire the power
supply as this will cause damage or
degrade to the product.
2) Do not connect terminals that are not
used. This can cause malfunction of the
sensor.
4. Cleaning
1) Since the pressure sensor chip is
exposed to the atmosphere, do not allow
cleaning fluid to enter inside.
2) Avoid ultrasonic cleaning since this
may cause breaks or disconnections in
the wiring.
5. Environment
1) Please avoid using or storing the
pressure sensor chip in a place exposed
to corrosive gases (such as the gases
given off by organic solvents, sulfurous
acid gas, hydrogen sulfides, etc.) which
will adversely affect the performance of
the pressure sensor chip.
2) To ensure resistance to power supply
superimposed noise, you must provide a
capacitor at the power supply input
terminal of the sensor in order to stabilize
the power supply voltage. We
recommend to provide 0.1 µF and 1,000
pF capacitor in parallel. Please confirm
the noise resistance with the actual
equipment and choose adequate
capacitor.
3) Since the internal circuitry may be
destroyed if an external surge voltages is
supplied, provide an element which will
absorb the surges.
4) Malfunctioning may occur if the
product is in the vicinity of electrical noise
such as that from static electricity,
lightning, a broadcasting station, an
amateur radio, or a mobile phone.
5) Since this pressure sensor chip does
not have a water-proof construction,
please do not use the sensor in a location
where it may be sprayed with water, etc.
6) Avoid using the pressure sensors chip
in an environment where condensation
may form.
Furthermore, its output may fluctuate if
any moisture adhering to it freezes.
7) The pressure sensor chip is
constructed in such a way that its output
will fluctuate when it is exposed to light.
Especially when pressure is to be applied
by means of a transparent tube, take
steps to prevent the pressure sensor chip
from being exposed to light.
8) Avoid using the pressure sensor chip
where it will be susceptible to ultrasonic
or other high-frequency vibration.
6. Quality check under actual loading
conditions
To assure reliability, check the sensor
under actual loading conditions. Avoid
any situation that may adversely affect its
performance.
7. Other handling precautions
1) That using the wrong pressure range
or mounting method may result in
accidents.
2) The only direct pressure medium you
can use is dry air. The use of other
media, in particular, corrosive gases
(organic solvent based gases, sulfurous
acid based gases, and hydrogen sulfide
based gases, etc.) and media that
contains moisture or foreign substances
will cause malfunction and damage.
Please do not use them.
3) The pressure sensor chip is positioned
inside the pressure inlet. Never poke
wires or other foreign matter through the
pressure inlet since they may damage
the chip or block the inlet. Avoid use
when the atmospheric pressure inlet is
blocked.
4) Use an operating pressure which is
within the rated pressure range. Using a
pressure beyond this range may cause
damage.
5) Since static charge can damage the
pressure sensor chip, bear in mind the
following handling precautions.
(1) When storing the pressure sensor
chips, use a conductive material to short
the pins or wrap the entire chip in
aluminum foil. Plastic containers should
not be used to store or transport the
chips since they readily become charged.
(2) When using the pressure sensor
chips, all the charged articles on the
bench surface and the work personnel
should be grounded so that any ambient
static will be safely discharged.
6) Based on the pressure involved, give
due consideration to the securing of the
pressure sensor DIP type and to the
securing and selection of the inlet tube.
Consult us if you have any queries.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB244E 201208-T

7페이지


구       성 총 7 페이지수
다운로드[ ADP5111.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
ADP5110

Pressure sensor

Panasonic
Panasonic
ADP5111

Pressure sensor

Panasonic
Panasonic

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵