No Preview Available ! SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SERVICE MANUAL
Wireless type
Models
MSZ-A09YV - E1 (WH)
MSZ-A12YV - E1 (WH)
No. OB327
Indication of model name
MSZ-A09YV - E1
MSZ-A12YV - E1
CONTENTS
1. PART NAMES AND FUNCTIONS······················2
2. SPECIFICATION·················································4
3. NOISE CRITERIA CURVES ·······························5
4. OUTLINES AND DIMENSIONS ·························6
5. WIRING DIAGRAM ············································7
6. REFRIGERANT SYSTEM DIAGRAM ················7
7. SERVICE FUNCTIONS ······································8
8. TROUBLESHOOTING······································10
9. DISASSEMBLY INSTRUCTIONS ····················19
10. PARTS LIST······················································21
11. OPTIONAL PARTS ···········································23
NOTE:
This service manual describes technical data of the indoor units.
•Refer to the service manual OB328 when MSZ-A09YV- E1 or MSZ-A12YV- E1 is connected
with MUZ-A09YV- E1 , MUZ-A12YV- E1 , MUZ-A09YVH- E1 or MUZ-A12YVH- E1 .
•Refer to the service manual OB319 when MSZ-A09YV- E1 or MSZ-A12YV- E1 is connected
with MXZ-A18WV- E1 , MXZ-A26WV- E1 or MXZ-A32WV- E1 as multi system units.
http://www.Datasheet4U.com
1 page 3 NOISE CRITERIA CURVES
MSZ-A09YV - E1
MSZ-A12YV - E1
FAN SPEED FUNCTION SPL(dB(A))
High
COOLING
HEATING
37
38
LINE
Test conditions,
Cooling : Dry-bulb temperature 27:
Heating : Dry-bulb temperature 20:
90
Wet-bulb temperature 19:
Wet-bulb temperature 15:
FAN SPEED FUNCTION SPL(dB(A))
High
COOLING
HEATING
39
38
LINE
Test conditions,
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
Heating : Dry-bulb temperature 20: Wet-bulb temperature 15:
90
80 80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20 APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NC-20
NOISE
10
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20 APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NC-20
NOISE
10
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
INDOORUNIT
1m
0.8m
MICROPHONE
WALL
5
5 Page 5. How to install the horizontal vanes
If horizontal vanes are not installed correctly, both of the operation indicator lamps will flash.
In this case, install the horizontal vanes correctly by following the procedures 1 to 6.
NOTE: Before installation of the horizontal vanes, disconnect the power supply plug and/ or turn off the breaker.
Upper vane
Insert this end first.
6 5 4Stopper
Stopper
Lower vane
Upper right
The holes on the
insertion ends of
the upper and lower
horizontal vanes
different shapes.
Lock.
Insert this end first.
3
Lock.
2
Insert.
In.
1
Lower right
Lock.
Lock.
Insert.
In.
In procedures 2,3,5, and 6, lock the stoppers until they click into place.
INFORMATION FOR MULTI SYSTEM AIR CONDITIONER
OUTDOOR UNIT : MXZ series
Multi system air conditioner can connect two or more indoor units with one outdoor unit.
•Unit won’t operate in case the total capacity of indoor units exceeds the capacity of outdoor units. Do not
connect indoor units beyond the outdoor unit capacity.
Operation indicator lamp flashes as shown in the figure below.
•When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and
the other for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor
units will start the operation later cannot operate, indicating as shown in the figure below. In this case, please
set all the indoor units to the same operation mode.
Operation Indicator
Lighted
Flashing
•When indoor units starts the operation while the defrosting of outdoor unit is being done, it takes a few min-
utes (max. 10 minutes) to blow out the warm air.
•In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant
flowing may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
11
11 Page |
Páginas | Total 24 Páginas | |
PDF Descargar | [ Datasheet MSZ-A12YV.PDF ] |
Número de pieza | Descripción | Fabricantes |
MSZ-A12YV | HEAT PUMP AIR CONDITIONERS SERVICE MANUAL | Mitsubishi |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |