No Preview Available ! Color Sensing Digital Fiber Sensor
E3X-DAC-S
Easy and Reliable
The Fiber Sensor That Sees in Color
• High-power white LED and multi-RGB processing eliminate the
need to select light source (wavelength) types.
• One-touch teaching enables stable detection that resists against
workpiece vibration.
• Choose from a wide range of Fiber Heads to match the workpiece
and working space.
CSM_E3X-DAC-S_DS_E_5_4
Refer to Safety Precautions on page 10.
Features
Easy and Reliable ... Featuring a Color-sensing Engine
A high-power white LED and a multi-RGB processing system
combine to cover all RGB wavelengths, enabling easy and
accurate detection of workpieces without having to use
a different light source to watch each one.
No Need
to Select
Colors are detected through changes in the ratio of three
parameters, RGB, to enable stable detection even when the
workpiece moves.
Intensity
Detection
(Previous Type)
Color Detection
(Color Sensing
Type)
Not
Affected
by
Move-
ment
Incident Light Intensity
80 to 130
RGB Ratio
Incorrect
operation is
a worry.
Operation is
reliable even
with workpiece
movement.
Easy and Reliable ... Ease of Use and Smart Functions
In addition to ensuring easy use, we have added a number of smart functions, such as remote control to simplify setup, and
twin sensing and output to simultaneously distinguish two registered colors. (advanced models)
Easy Setting with One-push Teaching
Wide Range of Fiber Heads Available
Select from a wide range of Fiber
Heads to match the workpiece and
working space.
Easy-to-Understand Double Display
Immediately check the degree of match
with the registered colors and the
thresholds or easily make fine
adjustment while checking these values.
Settings to teach the workpiece to be
detected can be easily performed with
one push.
10 mm
R
G
B
First in Its Class
Reliable Setting guide function.
This function guides the user to
ensure that the workpiece is in an
appropriate position for teaching.
(Indicates OVER, OK, or LOW.)
A Slim, 10-mm-wide Amplifier
Use of a white LED and a one-package
RGB light-receiving element results in a
slim Amplifier.
http://www.Datasheet4U.com
1
1 page E3X-DAC-S
Sensing Distance
Reflective Models
(Unit: mm)
Sensing object
White paper
Type
High-
resolu-
tion
mode
Stan-
dard
mode
High-
speed
mode
E32-DC200
70 54 46
E32-D11R/E32-D12R/
E32-D15XR/E32-D11N/
42
32
26
E32-DC200BR(B4R)
E32-D14LR
11 8.5
7
General-
purpose
E32-D15YR/E32-D15ZR
10
7.5
6.5
E32-D211/E32-DC200E/
Stan-
dard
models
E32-D22/E32-D25X/
E32-DC200F(F4)
E32-D24
20 16 14
8.8 6.7 5.8
E32-D25Y/E32-D25Z
5.8 4.5 3.8
E32-D11/E32-D15XB
42 32 26
Break-
E32-D21B/E32-D221B
19
15
13
resistant E32-D21/E32-D22B
8.8 6.7 5.8
E32-D25XB
14 10
9
Fluorine
coating
E32-D11U
42 32 26
Long dis- E32-A09
tance,
E32-D11L
high power E32-D21L/E32-D22L
20 to 38
90
35
24 to 36
70
26
26 to 32
60
22
E32-CC200
60 45 35
Special-
beam
E32-CC200R/E32-C11N 35 26 22
models Coaxial
E32-D32L
35 26 22
E32-C31/E32-D32
17 13 11
E32-C31N
7.7 6 4.8
Area
sensing
E32-D36P1
35 26 22
E32-D51
55 42 36
Environ- Heat-
ment resistant
E32-D81R-S/E32-D61-S
20
15
13
resis-
E32-D73-S
13 10 8.5
tive
models
Chemical
resistant
E32-D12F
E32-D14F
22 17 15
976
Super-
high-
speed
mode
18
11
2.5
2.5
5
2.1
1.4
11
4.5
2.1
3
11
---
22
8
16
9
9
4.5
2.1
9
14
5
3.5
6
2
Standard color card (11 colors)
(mutual determination)
High-
resolu-
tion
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
14 10 8.5
6
8.5 6 5 3.5
2.4 1.7 1.4
1
2.1 1.5 1.3 0.9
4.5 3 2.5 1.5
1.8 1.3 1.1
1.2 0.9 0.7
8.5 6 5
4.1 3 2.4
1.8 1.3 1.1
3 2.1 1.7
8.5 6 5
20 to 38 24 to 36 26 to 32
19 13 11
754
12 9 7
7.5 5 4.5
7.5 5 4.5
3.7 2.7 2.2
1.6 1.2 0.9
7.5 5 4.5
11 8.5
7
4 3 2.5
2.8 2 1.7
4.9 3.5 2.9
2.1 1.4 1.2
0.7
0.5
3.5
1.5
0.7
1.1
3.5
---
7.5
2.5
4
3
3
1.5
0.7
3
4.5
1.5
1.2
2
0.6
5
5 Page E3X-DAC-S
Precautions for Correct Use
Do not use the product in atmospheres or environments that
exceed product ratings.
Amplifier Unit
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power
supply is turned ON. If the Sensor and load are connected to
separate power supplies, be sure to turn ON the Sensor first.
Time may be required for the degree of match to stabilize after
the power supply is turned ON.
Operation When Turning Power OFF
Output pulses may occur when the power is turned OFF. Turn
OFF the power supply to the load and the load line before
turning OFF the power supply to the Sensor.
● Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
until it clicks into place.
Insert
2. Attach the protector seals (provided as accessories) to the
sides of master and slave connectors that are not
connected.
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and
press the Amplifier Units together until they click into place.
Click
into place
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from
the DIN track one at a time. (Do not attempt to remove
Amplifier Units from the DIN track without separating them
first.)
Note 1. The specifications for ambient temperature will vary according to the
number of Amplifier Unit used together. For details, refer to Ratings
and Specifications on ➜ page 3.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the
Amplifier Unit moving, e.g., due to vibration.
Seal
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is
to be removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down
on the lever on the Connector and remove it. (Do not
attempt to remove Connectors without separating them
from other Amplifier Units first.)
Press down
Lever
Remove
End Plate
11
11 Page |
Páginas | Total 16 Páginas | |
PDF Descargar | [ Datasheet E3X-DAC-S.PDF ] |
Número de pieza | Descripción | Fabricantes |
E3X-DAC-S | Color Sensing Digital Fiber Sensor | Omron Electronics |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |