DataSheet.es    


PDF DVI-2560 Data sheet ( Hoja de datos )

Número de pieza DVI-2560
Descripción DVI-D INTERFACE CONTROLLER
Fabricantes Digital View 
Logotipo Digital View Logotipo



Hay una vista previa y un enlace de descarga de DVI-2560 (archivo pdf) en la parte inferior de esta página.


Total 17 Páginas

No Preview Available ! DVI-2560 Hoja de datos, Descripción, Manual

DVI-D INTERFACE CONTROLLER
FOR 2560x1600 resolution TFT PANEL
Model: DVI-2560
Part number : 41713002X-3
INSTRUCTIONS
CONTENTS
Page: 2. Introduction, How to Proceed, Usage Note, Disclaimer
2. System design – Diagram of a suggested system
3. Assembly notes – Important information about system elements
5. Connection & Operation – How to use the controller
7. Connectors, pinouts & jumpers – Essential connection information
11. Controller dimensions
12. Application notes
13. Troubleshooting
14 Specifications
15 Appendix I – Graphic Mode Support Table
16. Warranty, Caution & Limitation of Liability, Trademarks
17. Contact details
It is essential that these instructions are read and understood before connecting or
powering up this controller.
1

1 page




DVI-2560 pdf
CONNECTION & OPERATION
CAUTION: Never connect or disconnect parts of the display system when the system is powered up as this may cause serious
damage.
CONNECTION
Connection and usage is quite straight forward (it is useful to have the relevant connection diagram available at this time):
1. LCD panel : This controller only support 18V 2560x1600 resolution panel model – LG LM300W01-A3, Samsung
LTB300M1-P01 and Samsung LTM300M1-P01.
2. TMDS panel cable connection : Plug the TMDS signal cable direct to CN1. Insert the panel end of the cable to the
LCD panel connector.
3. Panel power and control signal connection : Plug the panel power and control signal cable direct to CN2. Insert
the panel end of the cable to the LCD panel connector.
4. Inverter & Controller: Plug the inverter cable to CNA1, CNB1 and CNB2. Plug another end to the connector
on the panel built-in inverter.
5. Function switch & Controller: Plug the OSD switch mount cable to CNC1 on the controller board and another to
the OSD switch mount.
6. LED & Controller: Plug in a 3-way with dual colour LED to connector LED1A & LED2A on the controller board.
7. Jumpers : Check all jumpers are set correctly. Details referring the connection diagram at
http://www.digitalview.com/controllers/csg.php
8. Jumpers & Inverter & Panel voltage: Particularly pay attention to the settings of JB1, JB2, JB3. JB1 is used for
setting the backlight brightness control voltage range on specific inverter. JB2 & JB3 are used for inverter control
(read inverter specification and information on the jumper table to define the correct settings). This controller is now
always to default output 18V panel power.
8. DVI-D cable : Plug the DVI cable to the connector P1 on the controller board.
9. Power supply & Controller: Plug the DC 24V power in to the connector PP2. You can consider to use DigitalView
mating power cable P/N 426013700-3, 160mm.
10. Power on: Switch on the controller board and panel by using the OSD switch mount.
CAUTION: Never connect or disconnect parts of the display system when the system is powered up as this may cause serious
damage.
General:
If you are using supplied cables & accessories, ensure they are correct for the model of panel and controller.
If you are making your own cables & connectors refer carefully to both the panel & inverter specifications and the section
in this manual, “Connectors, Pinouts & Jumpers” to ensure the correct pin to pin wiring.
PC SETTINGS
The controller has been designed to support DVI 2560x1600 60Hz mode coming from graphics display card only.
OPERATION
The controller can allow you to switch on/off the board and controlling the backlight brightness via OSD switch mount.
5

5 Page





DVI-2560 arduino
CONTROLLER DIMENSIONS
The maximum thickness of the controller is 19.6mm (measured from bottom of PCB to top of components, including
any underside components & leads). We recommend clearances of:
5mm from bottom of PCB - if mounting on a metal plate we also recommend a layer of suitable insulation
material is added to the mounting plate surface.
10mm above the components
3~5mm around the edges
Any of the holes shown above can be used for mounting the PCB, they are 3.2mm in diameter.
CAUTION: Ensure adequate insulation is provided for all areas of the PCB with special attention to high
voltage parts such as the inverter.
11

11 Page







PáginasTotal 17 Páginas
PDF Descargar[ Datasheet DVI-2560.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DVI-2560DVI-D INTERFACE CONTROLLERDigital View
Digital View

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar