부품번호 | HAX2000-S 기능 |
|
|
기능 | Current Transducers HAX 500 to 2500-S | ||
제조업체 | LEM | ||
로고 | |||
전체 2 페이지수
Current Transducers HAX 500 to 2500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 500 .. 2500 A
VOUT = ± 4 V
Electrical data
Primary nominal
r.m.s. current
IPN (A)
500
850
1000
1200
1500
2000
2500
Primary current
measuring range
IP (A)
± 1500
± 2550
± 3000
± 3600
± 4500
± 5500
± 5500
Type
HAX 500-S
HAX 850-S
HAX 1000-S
HAX 1200-S
HAX 1500-S
HAX 2000-S
HAX 2500-S
V
C
IC
IOC
V
d
Vb
RIS
VOUT
ROUT
R
L
Supply voltage (± 5 %)
± 15
Current consumption
± 15
Overload capacity
30,000
R.m.s. voltage for AC isolation test, 60 Hz, 1 mn 5
R.m.s. rated voltage, safe separation
5001)
Isolation resistance @ 500 VDC
> 1000
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
± 4V ± 40
Output internal resistance
approx. 100
Load resistance
>1
Accuracy - Dynamic performance data
V
mA
At
kV
V
MΩ
mV
Ω
kΩ
X
εL
VOE
V
OH
εVOT
TC
G
tr
di/dt
f
Accuracy @ I , T = 25°C (without offset)
PN A
Linearity 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ I = 0;
P
after an excursion of 1 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth 3)(- 3 dB)
<±1
%
< ± 1 % of IPN
< ± 20
mV
< ± 30
mV
< ± 1 mV/K
< ± 0.1 %/K
< 5 µs
> 50
A/µs
DC .. 25 kHz
General data
TA Ambient operating temperature
T Ambient storage temperature
S
m Mass
- 25 .. + 85 °C
- 25 .. + 85 °C
approx. 450
g
Min. internal creepage distance/clearance
≥ 8.5
mm
Isolation material group
IIIa
Standards 4)
EN 50178
Notes : 1) Pollution class 2, overvoltage category III
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
4) Please consult characterisation report for more technical details and
application advice.
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 5000 V~
• Low power consumption
• Extended measuring range (3 x IPN)
• Package in PBT meets UL 94-V0
Advantages
• Easy mounting
• Small size and space savings
• Only one design for wide current
ratings range
• High immunity against external
interference
Applications
• AC motor speed control
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding, cable TV
and telecommunication applications.
031219/7
LEM Components
www.lem.com
| |||
구 성 | 총 2 페이지수 | ||
다운로드 | [ HAX2000-S.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
HAX2000-S | Current Transducers HAX 500 to 2500-S | LEM |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |