부품번호 | F-51430NFU-FW-AEN 기능 |
|
|
기능 | LCD Module | ||
제조업체 | OPTREX | ||
로고 | |||
LCD Module Technical Specification
Type No. F-51430NFU-FW-AEN
First Edition
Oct 17, 2005
Final Revision
******
Approved by (Quality Assurance Division)
)
Checked by (ACI Engineering Division)
)
Prepared by (ACI Engineering Division)
Table of Contents
1. General Specifications .................................................................................................................................. 2
2. Electrical Specifications ............................................................................................................................... 3
3. Optical Specifications ................................................................................................................................... 8
4. I/O Terminal.................................................................................................................................................... 10
5. Test................................................................................................................................................................... 12
6. Appearance Standards................................................................................................................................ 13
7. Code System of Production Lot............................................................................................................... 16
8. Type Number.................................................................................................................................................. 16
9. Applying Precautions .................................................................................................................................. 16
10. Precautions Relating Product Handling................................................................................................ 17
11. Warranty ........................................................................................................................................................ 18
Revision History
Rev. Date
Page
Comment
F-51430NFU-FW-AEN (AE) No. 2005-0082
OPTREX CORPORATION
Page 1/18
2.3.AC Characteristics
Parameter
Shift Clock Period
Shift Clock “H” Pulse Width
Shift Clock “L” Pulse Width
Data Setup Time
Data Hold Time
Latch Pulse “H” Pulse Width
Shift Clock Rise to Latch Pulse Rise Time
Shift Clock Fall to Latch Pulse Fall Time
Latch Pulse Rise to Shift Clock Rise Time
Latch Pulse Fall to Shift Clock Rise Time
Input Signal Rise,Fall Time
Data Setup Time
Data Hold Time
DISPOFF Removal Time
DISPOFF Enable Pulse Width
Symbol
tWCK
tWCKH
tWCKL
tDS
tDH
tWLPH
tLD
tSL
tLS
tLH
tr, tf
tSU
tH
tSD
tWDL
VCC=4.5~5.5V
Min.
Max.
Units
71 - ns
23 - ns
23 - ns
10 - ns
20 - ns
23 - ns
0 - ns
25 - ns
25 - ns
25 - ns
-
50 Note.1
ns
30 - ns
50 - ns
100 - ns
1.2 - µs
FLM
LP
CP
DU0~DU3
DL0~DL3
DISPOFF
tSU tH
t WLPH
t SL
tLD t LS
tr tf
tWCK
t LH
t WCKH
t DS
t WCKL
t DH
LAST DATA
TOP DATA
tWDL
t SD
F-51430NFU-FW-AEN (AE) No. 2005-0082
OPTREX CORPORATION
Page 4/18
4페이지 2.7.Lighting Specifications
Ta=25°C
Parameter
Symbol Conditions
Min.
Typ.
Max.
Units Notes
Lamp Voltage VL -
- 340 - Vrms 1
Lamp Current IL -
5.5 6.0 6.5 mArms 2
Starting Voltage
Surface Luminance
VS
L
-
IL=6.0mA
855
-
-
110
- Vrms 3
- cd/m2 4
Average Life
TAL IL=6.0mA - 10000 - hrs 5
Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after
lighting for 3 minutes .
Note 2 :The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured
after lighting for 3 minutes.
Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually
from 0V.
Note 4 :Surface Luminance is specified by the average of 9 luminance values measured at each
point shown above after 20 minutes power on with the all ON pattern adjusted to maximum
contrast and the dimming control of 100%. ( maximum brightness )
Note 5 : CFL Life is defined as time period that the actual luminance becomes 50% or lower of its
initial value.
The Average life time of CFL is defined as the time when half or more of the testing CFLs
have become less bright than 50% of the initial brightness at continuous operation.
I
N VS
V
C
VL F
L
Y=60 Y=320 Y=580
P1 P2 P3
P4 P5 P6
P7 P8 P9
X=60
X=240
X=420
IL
CFL Testing Circuit
Measurement Points
Recommended Inverter : S-12565 ( Produced by ELEVAM )
CXA-M10A (DC 5.0V, Produced by TDK)
CXA-M10L (DC 12.0V, Produced by TDK)
F-51430NFU-FW-AEN (AE) No. 2005-0082
OPTREX CORPORATION
Page 7/18
7페이지 | |||
구 성 | 총 18 페이지수 | ||
다운로드 | [ F-51430NFU-FW-AEN.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
F-51430NFU-FW-AEN | LCD Module | OPTREX |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |