부품번호 WS1302 기능
기능 Electric energy meter
제조업체 Iskra
로고 Iskra 로고


WS1302 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 4 페이지수

미리보기를 사용할 수 없습니다

WS1302 데이터시트, 핀배열, 회로
Electric energy meter
WS0101, WS0102, WS1102
WS0301, WS0302, WS1302
Picture 1: Electric energy meter WS0101
Picture 2: Electric energy meter WS0102
Picture 3: Electric energy meter WS1302
FEATURES:
Direct connection up to 65 A (WSX10X)
Connection with current transformer (WSX30X)
Industrial applications or meters with type approval
according to European Directive 2004/22/EC MID
Active energy - class B in compliance with EN
50470-3, class 1 in compliance with EN 62053-21
Reactive energy - class 2 in compliance with
EN 62053-23
Three-phase connection
Energy measurement in both directions
(import-export)
Microprocessor control
7 digit energy counter (WS0101, WS0301)
Double 7 digit energy counter (WS0102, WS0302)
LCD 9 digit display (WS1102, WS1302)
Tariff inputs (option)
Communication (option):
RS485 (MODBUS protocol)
Pulse outputs (option)
Housing for DIN rail mounting
Protective cover for terminals
(possible seal up against non-authorized access)
APPLICATION
The WSX10X energy meters are used for measuring energy
using direct connection in three-phase systems with current
up to 65A while the WSX30X meters are used for connection
with current transformers. Optional also the measurement of
apparent energy is possible. Housing is provided with
terminals protection covers, which can be seal up against
non-authorised access. They are built to be fastened to
EN 60715 standard guides. The meters are microprocessor
controlled. Display of quantities depends on meters type.
They can be displayed on 7 digit electromechanical counter
or on LCD display.
According to the customer's demands, meters can be
equipped with a RS485 serial communication (option) with
the MODBUS protocol, which enables data transmission and
thus connection of the measuring places into the network for
the control and management with energy. They can also be
equipped with tariff input (option).
A built-in pulse output (option) is designed for sending data
to the devices for checking and monitoring consumed
energy.
WWW.ISKRA-MIS.SI
LAYOUT AND MODE OF OPERATION
A method for sampling voltages and currents with an A/D
converter is used. Current inputs are electrically isolated
from the system by means of measuring transformer (4)
(Picture 4), voltages are measured by the resistor voltage
divider (3). Input currents are amplified in programmable
amplifier (5). After A/D conversion the signal is computed in
microprocessor (6). Not only data on the meter type but also
calibration constants are stored in the EEPROM (7). There
are no adjustable elements (potentiometers) in the meter,
which assures a better long-term stability. A built-in auto
range of current inputs assures accuracy also at small
currents. High rate of sampling enables measuring distorted
signals, as well.
One or two (optional) S0 output (10) is built into each meter.
A number of pulses depend on consumed energy. Measured
quantities are displayed on 7 digit electromechanical counter
(11) or on LCD display (8). LED diodes (9) are used for
detection of starting current, indication of communication
(transmission) and test output proportional to measured
power. LED diodes are only built in WS0X01 and WS0X02
meters.
Galvanic separated communication (12), RS485 enables
data transfer and tariff setting. Tariff can also be set via tariff
input (13) (option).
The meter is supplied from the measuring system. The
instrument electronic part is supplied via the supply
rectifier (2).
Picture 4: Block diagram
Page 1




WS1302 pdf, 반도체, 판매, 대치품
ENVIRONMENTAL CONDITIONS:
Climatic rating:
according to EN 50470-1: 2006
Indoor meter
Operating temperature
Storage temperature
Annual mean relative humidity:
-25 °C to +55 °C
-25 °C to +70 °C
95% r.h.
(without condensing)
Mechanical environments
M1
according to EN 50470-1: 2006
EU DIRECTIVES CORRESPONDING
FOR CE MARKING
Low voltage directive 2006/95/EC:
EN 61010-1: 2004 Safety requirements for electrical
equipment for measurement, control, and laboratory use,
Part 1: General requirements
EMC directive 2004/108/EC
Electromagnetic compatibility per EN 50470-1: 2006
Measuring instrument directive MID 2004/22/EC for active
energy (option MID)
DIMENSIONAL DRAWING
Picture 12: Dimensional drawing (all dimensions are in mm)
DATA FOR ORDERING
Sample:
Two tariff active energy meter for direct 4-wire connection
50 Hz 5(65) A with RS485 and one impulse output MID
approved - WS0102 model 41112210
* - Not available for MID approved meters
** - Quadrants of registered energy
*** - For MID approved meters with primary metering the primary
current must be specified at order - fixed parameters. For industrial
meters WS030X the primary current of CT shall be specified for
primary metering due to counter resolution. For industrial meters
WS1302 with RS485 communication any primary current of CT and
resolution can be set afterwards using communication.
WS X X 0 X
0 - electromechanical register
1 - LCD display
1 - direct connection
3 - connection with current transformers
1 - one electromechanical register
2 - two electromechanical registers or LCD
Model X X X X X X X X
X
Meter connection
1 - meter for 3 wire network
2 - meter for 4 wire network
3 - meter for 3 wire network - MID
4 - meter for 4 wire network - MID
Current range/Frequency (only WSX10X)
1 - 5 (65) A - 50 Hz
2 - 10 (63) A - 50 Hz
3 - for CT In 5 A - primary metering***
4 - for CT In 1 A - primary metering***
5 - for CT In 5 A - secondary metering
6 - for CT In 1 A - secondary metering
7 - 5 (65) A - 60 Hz
8 - 10 (63) A - 60 Hz
Communication interface
0 - without communication interface
1 - RS 485 communication
Tariff inputs
0 - no tariff inputs
1 - one tariff input (T1/T2)
2 - two tariff inputs (4 tariffs) *
Register 1
1 - active energy (I+IV** - all tariffs)
2 - active energy (I+IV - T1)
3 - active energy (II+III - all tariffs)
4 - absolute active energy (all tariffs)
5 - reactive energy (I+II - all tariffs) *
6 - reactive energy (absolute - all tariffs) *
7 - reactive energy (III+IV - all tariffs) *
9 - custom specification *
Register 2
0 - no register - disabled
1 - active energy (II+III - all tariffs)
2 - active energy (I+IV - T2)
3 - active energy (I+IV - all tariffs)
4 - absolute active energy (all tariffs)
5 - reactive energy (I+II - all tariffs)
6 - reactive energy (absolute - all tariffs)
7 - reactive energy (III+IV - all tariffs)
9 - custom specification *
Impulse output 1
0 - no register - disabled
1 - active energy (I+IV - all tariffs)
2 - active energy (I+IV - T1)
3 - active energy (II+III - all tariffs)
4 - absolute active energy (all tariffs)
5 - reactive energy (I+II - all tariffs)
6 - reactive energy (absolute - all tariffs)
7 - reactive energy (III+IV - all tariffs)
9 - custom specification *
Impulse output 2
0 - no register - disabled
1 - active energy (II+III - all tariffs)
2 - active energy (I+IV -T2)
3 - active energy (I+IV - all tariffs)
4 - absolute active energy (all tariffs)
5 - reactive energy (I+II - all tariffs)
6 - reactive energy (absolute - all tariffs)
7 - reactive energy (III+IV - all tariffs)
9 - custom specification *
Primary current (only WSX30X)
X - primary current value in A***
Printed in Slovenia Subject to change without notice Version 10 / Sep-2010E P22.433.000

4페이지












구       성 총 4 페이지수
다운로드[ WS1302.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
WS1302

Electric energy meter

Iskra
Iskra

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵