1. Feature & Application:
*High precision
*Capacitive type
*Full range temperature compensated
*Relative humidity and temperature measurement
*Calibrated digital signal
*Outstanding long-term stability
*Extra components not needed
*Long transmission distance, up to 100 meters
*Low power consumption
*4 pins packaged and fully interchangeable
2. Description:
RHT03 output calibrated digital signal. It applys exclusive digital-signal-collecting-technique and humidity
sensing technology, assuring its reliability and stability. Its sensing elements is connected with 8-bit single-chip
computer.
Every sensor of this model is temperature compensated and calibrated in accurate calibration chamber and the
calibration-coefficient is saved in type of programme in OTP memory, when the sensor is detecting, it will cite
coefficient from memory.
Small size & low consumption & long transmission distance(100m) enable RHT03 to be suited in all kinds of
harsh application occasions. Single-row packaged with four pins, making the connection very convenient.
3. Technical Specification:
Model
Power supply
Output signal
Sensing element
Operating range
Accuracy
Resolution or sensitivity
Repeatability
RHT03
3.3-6V DC
digital signal via MaxDetect 1-wire bus
Polymer humidity capacitor
humidity 0-100%RH;
temperature -40~80Celsius
humidity +-2%RH(Max +-5%RH); temperature +-0.5Celsius
humidity 0.1%RH;
temperature 0.1Celsius
humidity +-1%RH;
temperature +-0.2Celsius
-1-
MaxDetect Technology Co., Ltd.
-----------------------------------------
Thomas Liu (Sales Manager)
Email: [email protected] , [email protected]
http://www.humiditycn.com
Your specialist in innovating humidity & temperature sensors
------------------------------------------------------------------------------------------------------------------------------------
1) Step 1: MCU send out start signal to RHT03 and RHT03 send response signal to MCU
Data-bus's free status is high voltage level. When communication between MCU and RHT03 begins, MCU
will pull low data-bus and this process must beyond at least 1~10ms to ensure RHT03 could detect MCU's signal,
then MCU will pulls up and wait 20-40us for RHT03's response.
When RHT03 detect the start signal, RHT03 will pull low the bus 80us as response signal, then RHT03 pulls
up 80us for preparation to send data. See below figure:
------------------------------------------------------------------------------------------------------------------------------------
2). Step 2: RHT03 send data to MCU
When RHT03 is sending data to MCU, every bit's transmission begin with low-voltage-level that last 50us, the
following high-voltage-level signal's length decide the bit is "1" or "0". See below figures:
-4-
MaxDetect Technology Co., Ltd.
-----------------------------------------
Thomas Liu (Sales Manager)
Email: [email protected] , [email protected]
http://www.humiditycn.com
4페이지 | |||
구 성 | 총 6 페이지수 | ||
다운로드 | [ RHT03.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
RHT02 | Digital relative humidity & temperature sensor | MaxDetect |
RHT03 | Digital relative humidity & temperature sensor | MaxDetect |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |