DataSheet.es    


PDF MLX90616ESF-HCA Data sheet ( Hoja de datos )

Número de pieza MLX90616ESF-HCA
Descripción Infra Red Thermometer
Fabricantes Melexis 
Logotipo Melexis Logotipo



Hay una vista previa y un enlace de descarga de MLX90616ESF-HCA (archivo pdf) en la parte inferior de esta página.


Total 30 Páginas

No Preview Available ! MLX90616ESF-HCA Hoja de datos, Descripción, Manual

MLX90616ESF-HCA
Infra Red Thermometer in TO-39
for high temperature thermometer guns
Features and Benefits
‰ Easy to integrate
‰ Factory calibrated in wide temperature range
-40…+85 ˚C for sensor temperature
‰ Measurement range -70°C to 1030°C
‰ Measurement resolution of 0.02°C
‰ Built in thermal gradient compensation sensor
for fast, stable readings
‰ SMBus compatible digital interface
‰ Customizable PWM output for continuous
reading
‰ 3V supply voltage;
‰ Sleep mode for reduced power consumption
‰ 8-14um spectral sensitivity
Applications Examples
‰ Sensor element for high temperature
thermometer guns
Ordering Information
Part No.
MLX90616
Temperature
Code
E:(-40°C to 85°C)
Package
Code
SF (TO-39)
-Option Code
-X X X
(1) (2) (3)
Standard
Part
-000
Packing
Form
- TU
(1) Supply Voltage/ Accuracy (2) Number of thermopiles (3) Package options:
H - 3V , no IR calibration
C – gradient compensated: A – Standard package
See page 2
Example:
MLX90616ESF-HCA-000-TU
1 Functional diagram
J1
SCL
1 MLX90616
SCL U1
SDA
PWM
2 SDA
Vss 4
Vdd
GND
Vdd C1
3
CON1
0.1uF
MLX90616 connection to SMBus
Figure 1: Typical application schematics
2 General Description
The MLX90616 is an Infra Red thermopile sensor for high
temperature non-contact thermometers. Both the IR
sensitive thermopile detector chip and the signal
conditioning ASSP are integrated in the same TO-39 can.
A low noise amplifier, 17-bit ADC and powerful DSP unit,
result in a high accuracy and resolution of the
thermometer. The ambient temperature sensor in the
MLX90616 is calibrated in the factory. The digital interface
of the sensor is SMBus compatible.
The MLX90616 is intended to be used in applications where the user places a lens in front of the sensor to
adjust the FOV to his application. The sensor-lens combination temperature measurement has to be
calibrated by the customer. Melexis provides the necessary software to do this in an engineering
controlled environment.
The MLX90616 consists of a chipset developed and manufactured by Melexis:
The Infra Red thermopile detector MLX81101
The signal conditioning ASSP MLX90302, specially designed to process the output of IR sensor.
The device is available in an industry standard TO-39 package.
3901090616
Rev 002
Page 1 of 36
Data Sheet
August 20, 20121

1 page




MLX90616ESF-HCA pdf
MLX90616ESF-HCA
Infra Red Thermometer in TO-39
for high temperature thermometer guns
6 Pin definitions and descriptions
4- VSS 1- SCL
3- VDD 2- SDA/PWM
= Bottom View
Figure 2: Pin description
Pin Name
SCL
SDA / PWM
VDD
VSS
Function
Serial clock input for 2 wire communications protocol.
Digital input / output. In normal mode the measured object temperature is available at this pin Pulse
Width Modulated.
In SMBus compatible mode automatically configured as open drain NMOS.
External supply voltage.
Ground. The metal can is also connected to this pin.
Table 2: Pin description MLX90616
With the SCL and PWM / SDA pins operated in 2-wire interface mode, the input Schmitt trigger function is
automatically enabled.
3901090616
Rev 002
Page 5 of 36
Data Sheet
August 20, 20121

5 Page





MLX90616ESF-HCA arduino
MLX90616ESF-HCA
Infra Red Thermometer in TO-39
for high temperature thermometer guns
The address ConfigRegister1 consists of control bits for configuring the analog and digital parts:
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 ConfigRegister1 bit meaning
0 0 0 - IIR (5) a1 =0.5, b1 = 0.5
0 0 1 - IIR (6) a1 =0.25, b1 = 0.75
0 1 0 - IIR (7) a1 =0.166(6), b1 = 0.83(3)
0 1 1 - IIR (8) a1 =0.125, b1 = 0.875
1 0 0 - IIR (1) a1 =1, b1 = 0 (IIR bypassed)
1 0 1 - IIR (2) a1 =0.8, b1 = 0.2
1 1 0 - IIR (3) a1 =0.666, b1 = 0.333
1 1 1 - IIR (4) a1 =0.571, b1 = 0.428
0 - Repeat sensor test "OFF"- Do NOT alter
1 - Repeat sensor test "ON"- Do NOT alter
0 0 - Ta, Tobj
0 1 - not valid
1 0 - not valid
1 1 - not valid
0 - sensor selectio
1 - not valid
0 - Positive sign of Ks
1 - Negative sign of Ks
0 0 0 - FIR = 8, not recommended
0 0 1 - FIR = 16, not recommended
0 1 0 - FIR = 32, not recommended
0 1 1 - FIR = 64, not recommended
1 0 0 - FIR = 128
1 0 1 - FIR = 256
1 1 0 - FIR = 512
1 1 1 - FIR = 1024
0 0 0 GAIN = 1, Amp. Bypassed
0 0 1 GAIN = 3
0 1 0 GAIN = 6
0 1 1 GAIN = 12.5
1 0 0 GAIN = 25
1 0 1 GAIN = 50
1 1 0 GAIN = 100
1 1 1 GAIN = 100
0 - Positive sign of Kt2
1 - Negative sign of Kt2
0 - Enable sensor test
1 - Disable sensor test
Note: The following bits/registers should not be altered (except with special tools – contact Melexis for tools
availability) in order to keep the factory calibration relevant: Ke [15..0] ; Config Register1 [13..11;7;3] ;
addresses 0x00F and 0x019.
Table 6: Configuration register 1
3901090616
Rev 002
Page 11 of 36
Data Sheet
August 20, 20121

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet MLX90616ESF-HCA.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MLX90616ESF-HCAInfra Red ThermometerMelexis
Melexis

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar