DataSheet.es    


PDF MG5223 Data sheet ( Hoja de datos )

Número de pieza MG5223
Descripción S-Band Magnetron
Fabricantes Marconi 
Logotipo Marconi Logotipo



Hay una vista previa y un enlace de descarga de MG5223 (archivo pdf) en la parte inferior de esta página.


Total 5 Páginas

No Preview Available ! MG5223 Hoja de datos, Descripción, Manual

Marconi Applied Technologies
MG5223
S-Band Magnetron
The data should be read in conjunction with the Magnetron
Preamble.
ABRIDGED DATA
Fixed frequency pulse magnetron.
Operating frequency . . . . . 3050 + 10
MHz
Typical peak output power . . . . . . 30
kW
Magnet . . . . . . . . . . . . . . . integral
Output . . . . . . . . . . . . no. 10 waveguide
Coupler . . . mates with NATO S.N. 5985-99-083-0058
Cooling . . . . . . . . . . . natural or forced-air
GENERAL DATA
Electrical
Cathode . . . . . . . . . . . . indirectly heated
Heater voltage (see note 1) . . . . . . . 6.3
V
Heater current at 6.3 V . . . . . . . . 1.25
A
Heater starting current, peak value,
not to be exceeded . . . . . . . . . 6.0 A max
Cathode pre-heating time (minimum) . . . 180
s
Mechanical
Overall dimensions . . . . . . . . . . . see outline
Net weight . . . . . . . . . . . . 2.1 kg approx
Mounting position . . . . . . . . . . . . . any
A minimum clearance of 50 mm must be maintained between
the magnetron and any magnetic materials.
Cooling (see note 2) . . . . . . . natural or forced-air
MAXIMUM AND MINIMUM RATINGS
(Absolute values)
These ratings cannot necessarily be used simultaneously, and
no individual rating should be exceeded.
Min Max
Heater voltage (see note 1) . . . . . 5.7
Heater starting current (peak) . . . . –
Anode voltage (peak) . . . . . . . 7.5
Anode current (peak) . . . . . . . 6.0
Anode input power (mean) (see note 3) . –
Duty cycle . . . . . . . . . . –
Pulse duration . . . . . . . . . –
Rate of rise of voltage pulse
(see note 4) . . . . . . . . . –
VSWR at the output coupler . . . . –
Anode temperature (see note 2) . . . –
6.9
6.0
8.5
12
100
0.001
1.2
V
A
kV
A
W
ms
150 kV/ms
1.5:1
120 8C
TYPICAL OPERATION
Operating Conditions
Condition
12
Heater voltage . . . . . . . . . 5.3 6.3 V
Anode current (peak) . . . . . . . 8.0 8.0 A
Pulse duration . . . . . . . . . 0.55 0.07 ms
Pulse repetition rate . . . . . 1000 4000 pps
Rate of rise of voltage pulse . . . . 150 150 kV/ms
Typical Performance
Anode voltage (peak) . . . . . . . 8.0
Output power (peak) . . . . . . 30
Output power (mean) . . . . . . 16.5
8.0 kV
30 kW
8.4 W
Marconi Applied Technologies Limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU England Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492
e-mail: [email protected] Internet: www.marconitech.com Holding Company: Marconi p.l.c.
Marconi Applied Technologies Inc. 4 Westchester Plaza, PO Box 1482, Elmsford, NY10523-1482 USA Telephone: (914) 592-6050 Facsimile: (914) 592-5148 e-mail: [email protected]
# 2001 Marconi Applied Technologies Limited
A1A-MG5223 Issue 2, December 2001
181/6142

1 page




MG5223 pdf
HEALTH AND SAFETY HAZARDS
Marconi Applied Technologies magnetrons are safe to handle
and operate, provided that the relevant precautions stated
herein are observed. Marconi Applied Technologies does not
accept responsibility for damage or injury resulting from the use
of electronic devices it produces. Equipment manufacturers and
users must ensure that adequate precautions are taken.
Appropriate warning labels and notices must be provided on
equipments incorporating Marconi Applied Technologies
devices and in operating manuals.
High Voltage
Equipment must be designed so that personnel cannot come
into contact with high voltage circuits. All high voltage circuits
and terminals must be enclosed and fail-safe interlock switches
must be fitted to disconnect the primary power supply and
discharge all high voltage capacitors and other stored charges
before allowing access. Interlock switches must not be
bypassed to allow operation with access doors open.
RF Radiation
Personnel must not be exposed to excessive RF radiation. All
RF connectors must be correctly fitted before operation so that
no leakage of RF energy can occur and the RF output must be
coupled efficiently to the load. It is particularly dangerous to
look into open waveguide or coaxial feeders while the device is
energised. Screening of the cathode sidearm of high power
magnetrons may be necessary.
X-Ray Radiation
High voltage magnetrons emit a significant intensity of X-rays
not only from the cathode sidearm but also from the output
waveguide. These rays can constitute a health hazard unless
adequate shielding for X-ray radiation is provided. This is a
characteristic of all magnetrons and the X-rays emitted
correspond to a voltage much higher than that of the anode.
Whilst Marconi Applied Technologies has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any
use thereof and also reserves the right to change the specification of goods without notice. Marconi Applied Technologies accepts no liability beyond that set out in its
standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein.
# 2001 Marconi Applied Technologies
Printed in England
MG5223, page 5

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet MG5223.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MG5223S-Band MagnetronMarconi
Marconi

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar