부품번호 | AS-404 기능 |
|
|
기능 | Current Sense Inductors | ||
제조업체 | Talema Electronic | ||
로고 | |||
전체 2 페이지수
www.DataSheet4U.com
AS Series • Current Sense Inductors & Transformers
AS Series Current Sensors are designed as a low cost method of
controlling, monitoring or measuring AC currents. The sensors serve as
feedback elements between the output and pulse control circuitry providing
accurate regulation of switch mode power supplies.
Features
• Fully encapsulated for optimal PC board mounting
• Frequency range from 20kHz to 200kHz
• Primary current rating to 15 Amps
• Primary to secondary isolated to 2500 VAC
• Meets VDE norms
• Optimum performance over designated current and
frequency range
• Competitive pricing due to high volume production
• Manufactured in ISO-9001 approved facility
Applications
Isolated current feed-back signal in Switch Mode Power Supplies • Motor current load/overload • Lighting • Switch Controls Ultra-sound
current • High resolution sonar current •
Isolated bi-directional current sensor with full wave bridge rectifier
Electrical Specifications at 25°C
Part Number
AS-100
AS-101
AS-102
AS-103
AS-104
AS-105
AS-110
AS-111
AS-112
AS-113
AS-114
AS-115
Prim./Sec.
Ratio
1:50
1:100
1:200
1:300
1:500
1:750
1:50CT
1:100CT
1:200CT
1:300CT
1:500CT
1:750CT
Lsec (1)
(mH Min)
6
25
100
250
700
1682
6
25
100
250
700
1682
DCRsec
(Ohms Max.)
Sec. Term. (2)
Resistance
(Ohms Nom.)
0.6 50
1.1 100
4.5 200
D10a.t0aSheet4U.c3o0m0
25.0 500
43.0 750
0.3 / 0.3
25 + 25
0.55 / 0.55
50 + 50
2.25 / 2.25
100 + 100
5.0 / 5.0
150 + 150
12.5 / 12.5
250 + 250
21.5 / 21.5
375 + 375
Isec (3)
Max.
300mA
150mA
75mA
50mA
30mA
40mA
300mA
150mA
75mA
50mA
30mA
40mA
Volt µS (4)
Max.
175
350
700
900
1500
3750
175
350
700
900
1500
3750
Schematic
1
3 DataShee
1
2
3
Notes:
1) Lsec: Secondary inductance tested at 10kHz and 10mV for 1:50 through 1:500
Prim./Sec. ratios and 1kHz/10mV for Prim./Sec. ratio of 1:750
2) This nominal termination resistance value will yield approximately 1.0V
of output for each amp of current in a single turn sense line. The output
Voltage/Ampere of these devices can be increased or decreased linearly
over a restricted temperature range by adjusting the terminating resistance.
3) For Prim./Sec. Ratios of 1:50 through 1:500, the Isec value corresponds to a
maximum primary current of 15 Amp-turns rms while the Isec value for the ratio of
1:750 corresponds to a max. primary current of 30 Amp-turns rms.
1
4) VµS = R t x Is x 2F
Rt (Ohms): Recommended Terminating Resistance
Is (A): Secondary Current
F (Hz): Frequency
5) Operating Temperature Range: -40°C to +120°C
6) Pin 2 is on Center-Tapped (CT) versions only
17.2
(0.677)
17.0
(0.669)
0.60 Ø
(0.024)
TALEMA
ASXXX
12 3
5.0
(0.197)
20.4
(0.803)
6.35
(0.250)
12.7
(0.500)
+
4 .0 (0.157)
9.53
(0.375) 1
23
+_
_
Primary Sense Current
DataSheet4U.com
THE TALEMA GROUP • World Wide Toroidal Specialists
(07-03) AS Series
DataSheet4 U .com
| |||
구 성 | 총 2 페이지수 | ||
다운로드 | [ AS-404.PDF 데이터시트 ] |
당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는 |
구매 문의 | 일반 IC 문의 : 샘플 및 소량 구매 ----------------------------------------------------------------------- IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한 광범위한 전력 반도체를 판매합니다. 전력 반도체 전문업체 상호 : 아이지 인터내셔날 사이트 방문 : [ 홈페이지 ] [ 블로그 1 ] [ 블로그 2 ] |
부품번호 | 상세설명 및 기능 | 제조사 |
AS-400 | Current Sense Inductors | Talema Electronic |
AS-401 | Current Sense Inductors | Talema Electronic |
DataSheet.kr | 2020 | 연락처 | 링크모음 | 검색 | 사이트맵 |