Datasheet.kr


KPF601G01A 데이터시트 PDF : 부품 기능 및 핀배열

부품번호 KPF601G01A
기능 Semiconductor Pressure Sensor
제조업체 KEC
로고 ( 디자인 ) KEC 로고 
미리보기

( 핀배열 )


전체 4 페이지

		
KPF601G01A 데이터시트 및 KPF601G01A PDF

1페이지

KPF601G01A pdf, 반도체, 판매, 대치품
KPF500G01A ~ KPF102G01A
Note
1. Mounting on printed circuit boards
When mounting a transistor on a printed circuit, it is assumed that
lead wires will be processed or reformed due to space limitation or
relations with other components. Even if no such special
processing reforming is conducted exercise care on the following
points :
(a) Make the spaces of lead wire inserting holes on the printed
circuit board the same as those of lead wires on a transistor.
(b) Even if The spaces are not the same, do not pull the lead
wires or push heavily against the sensor element.
(c) Use a spacer for form a lead maintain space between a sensor
and a printed circuit board, rather than closely contacting
them with each other.
(d) When forming a lead prior to mounting onto a board
- Bend the lead at a point 3mm or more apart from the
body(Lead root).
- Bend one lead wire after securing the other lead wire. (near
the main body)
- Keep space between the sensor main body and and a fixing
jig.
- When bending the lead along the jig, be careful not to
damage it with an edge of the jig.
- Follow other precautions described in respective standard
(e) When mounting a sensor onto a heat sink
- Use the specified accessory.
- Drill threaded holes on the heat kink as per specifications
and keep the surface free from burrs and undulations.
- Use KEC’s recommended silicon grease.
- Tighten the screw within the specified torque.
- Never apply a pneumatic screwdriver to a transistor main
body.
(f) Do not bend or stretch the lead wires repeatedly.
When pulling in the axial directions, apply 500g or 600g
power, depending on the shapes of lead wires.
2. Soldering
When soldering a sensor to a printed circuit board, the soldering
temperature is usually so high that it adversely affects the sensor.
Normally, tests are conducted at a soldering temperature of 265
for 10 seconds or 300 for 3 seconds. Be sure to complete
soldering procedures under these conditions of temperature and
time.
Be careful to select a type of flux that will neither corrode the
lead wires nor affect the electrical characteristics of a sensor.
The basic precautions for soldering procedures are as follows :
(a) Complete soldering procedures in a time as short as possible.
(b) Do not apply stress to a sensor after soldering by correcting
or modifying its location or direction.
(c) For a sensor employing a heat sink, mount it on the heat sink
first: then solder this unit to a printed circuit board after
confirming that it is fully secured.
(d) Do not directly solder the heat-radiating portion of a sensor
to a printed circuit board.
(e) In flow solder jobs, sensors are apt to float on the solder due
to solder surface tension. When adjusting the locations of
sensor, be careful not to apply excessive stress to the roots of
the sensor lead wires.
(f) When using a soldering iron select those which have less
leakage, and be sure to ground the soldering iron.
3. Cleaning a circuit board
After soldering, circuit boards must be cleaned to remove flux.
Observe the following precautions while cleaning them
(a) When cleaning circuit boards to remove flux, make sure that
no residual reactive ions such as Na or Cl ions remain. Note
that organic solvents react with water to generate hydrogen
chloride and other corrosive gases which can degrade device
performance.
(b) Do not rub the indication marks with a brush or ones fingers
when cleaning or while a cleaning agent is applied to the
markings.
(c) There are ultrasonic wave cleaning methods which offer a
high cleaning effect within a short time. Since there methods
involve a complicated combination of factors such as the
cleaning bath size, ultrasonic wave vibrator output, and
printed circuit board mounting method, there is fear that the
service life of airtight seal-type sensors may be extremely
shortened. Therefore, as far as possible avoid using the
ultrasonic wave cleaning method.
- Basic requirements of ultrasonic wave cleaning method.
Frequency : 27~29kHz
Output : 300W or less (300W/ or less)
Recommended solvents : Refer to details above
Cleaning time : 30seconds or less
Application circuit
The Pressure sensor is designed to convert a voltage by means of
constant current drive and then, if nesessary, it amplifies the
voltage for use. The circuit shown below is a typical example of a
circuit in which the pressure sensor is used.
Constant Current
Circuit Unit
Pressure
Sensor
Amplifier Circuit Unit
OP
AMP
OP
AMP
OP
AMP
2007. 6. 15
Revision No : 2
4/4

4페이지






구       성총 4 페이지
다운로드[ KPF601G01A.PDF 데이터시트 ]
구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-------------------------------------------------------------------------------------------

전력 반도체 판매 ( IGBT, TR 모듈, SCR, 다이오드 모듈 ) : 010-3582-2743

상호 : 아이지 인터내셔날, 전화번호 : 051-319-2877, [ 홈페이지 ]



링크공유

링크 :

관련 데이터시트

부품번호상세설명 및 기능제조사
KPF601G01

The functions of this components is a Semiconductor Pressure Sensor.

KEC
KEC
KPF601G01A

The functions of this components is a Semiconductor Pressure Sensor.

KEC
KEC

추천 데이터시트

부품번호상세설명 및 기능제조사
2P4M

이 부품은 2A, 400V, P gate all diffused mold type Thyristor 입니다. The 2P4M and 2P6M are a P gate all diffused mold type Thyristor granted 2 A On-state Average Current (TC = 77°C), with rated voltages up to 600 V.

NEC
NEC
CQ1565RT

FSCQ1565RT, Green Mode Fairchild Power Switch. In general, a Quasi-Resonant Converter (QRC) shows lower EMI and higher power conversion efficiency compared to conventional hard-switched converter with a fixed switching frequency.

Fairchild
Fairchild
KF16N25D

MOSFET의 기능은 N Channel MOS Field effect transistor입니다. This planar stripe MOSFET has better characteristics, such as fast switching time, low on resistance, low gate charge and excellent avalanche characteristics. It is mainly suitable for DC/DC Converters and switching mode power supplies.( Vdss=250V, Id=13A )

KEC
KEC
FR9884

컨버터의 기능은 340KHz Synchronous Step-Down DC/DC Converter 입니다. The FR9884 is a synchronous step-down DC/DC converter that provides wide 4.5V to 18V input voltage range and 3A continuous load current capability.

Fitipower
Fitipower

www.DataSheet.kr    |   2018   |  연락처   |  링크모음   |   검색  |   사이트맵