부품번호 KPF801G03 기능
기능 Semiconductor Pressure Sensor
제조업체 KEC
로고 KEC 로고


KPF801G03 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.



전체 4 페이지수

미리보기를 사용할 수 없습니다

KPF801G03 데이터시트, 핀배열, 회로
SEMICONDUCTOR
TECHNICAL DATA
KPF500G03 ~ KPF102G03
Semiconductor Pressure Sensor
FEATURES
Broad Pressure Range : 50~1,000kPa.
High Sensitivity, Excellent Linearity.
Highly Stable in Temperature Change.
APPLICATIONS
Medical Deivces.
Industrial Instrumentations.
Pressure Switch, Water Height Control, Pneumatic Devices etc.
Home Appliances.
MODEL NUMBER FOR ORDERING
KP F 000 G 00 A
Silicon Pressure Sensor
Package Pin Configuration
No Mark : Standard
A : Type 1
ON/OFF Chip
N:ON Chip (Amplified)
F:OFF Chip (Not Amplified)
Rated Pressure
123 12 103=12,000kPa
Measuring Pressure
A : Absolute Pressure
D : Differential Pressure
G : Gage Pressure
Package Type
00 : Die
01~ : Package Series
PSM1
MAXIMUM RATING
ITEM
SPEC.
UNIT
Model No.
Classification
Rated Pressure
Measurable Pressure Range
Maximum Pressure Load
Bridge Impedance
Operating Temperature
KPF500G03 KPF101G03 KPF201G03 KPF401G03 KPF601G03
500 101 201 401 601
50 100 200 400 600
0.51 1.02 2.04 4.08 6.12
-50 ~ 50 -100 ~ 100 -100 ~ 200 -100 ~ 400 -100 ~ 600
Twice of Rated Pressure
3000 ~ 6000
-20 ~ 100
KPF801G03 KPF102G03
-
801 102 -
800
1000
kPa
8.16
10.20
kgf/
-100 ~ 800 -100 ~ 1000
kPa
1.5 Times of Reated Pressure kPa(kgf/ )
Storage Temperature
-40 ~ 120
ELECTRICAL CHARACTERISTICS
ITEM
SPEC.
Classification
500 101 201 401 601 801
Test Condition
Compensational Temperature Range
Operating Input Current 1.5 constant, Ambient Temperature Ta=25
0 ~ 50
Full Scale Voltage
60 ~ 140
Offset Voltage
20
Linearity
Pressure Hysteresis
Mechanical Response Time
0.3
0.5
2
Temperature Coefficient Of Offset (TCO)
5.0
Temperature Coefficient Of Sensitivity (TCS)
2.5
Comment) 1. Operating humidity 25~80%RH. (unless otherwise noted)
2. Please, consult us when you use any other pressure media except air.
102
UNIT
-
-
mV
mV
%FS
%FS
msec
%FS
%FS
2007. 6. 15
Revision No : 8
1/4




KPF801G03 pdf, 반도체, 판매, 대치품
KPF500G03 ~ KPF102G03
Note
1. Mounting on printed circuit boards
When mounting a transistor on a printed circuit, it is assumed that
lead wires will be processed or reformed due to space limitation or
relations with other components. Even if no such special
processing reforming is conducted exercise care on the following
points :
(a) Make the spaces of lead wire inserting holes on the printed
circuit board the same as those of lead wires on a transistor.
(b) Even if The spaces are not the same, do not pull the lead
wires or push heavily against the sensor element.
(c) Use a spacer for form a lead maintain space between a sensor
and a printed circuit board, rather than closely contacting
them with each other.
(d) When forming a lead prior to mounting onto a board
- Bend the lead at a point 3mm or more apart from the
body(Lead root).
- Bend one lead wire after securing the other lead wire. (near
the main body)
- Keep space between the sensor main body and and a fixing
jig.
- When bending the lead along the jig, be careful not to
damage it with an edge of the jig.
- Follow other precautions described in respective standard
(e) When mounting a sensor onto a heat sink
- Use the specified accessory.
- Drill threaded holes on the heat kink as per specifications
and keep the surface free from burrs and undulations.
- Use KEC’s recommended silicon grease.
- Tighten the screw within the specified torque.
- Never apply a pneumatic screwdriver to a transistor main
body.
(f) Do not bend or stretch the lead wires repeatedly.
When pulling in the axial directions, apply 500g or 600g
power, depending on the shapes of lead wires.
2. Soldering
When soldering a sensor to a printed circuit board, the soldering
temperature is usually so high that it adversely affects the sensor.
Normally, tests are conducted at a soldering temperature of 265
for 10 seconds or 300 for 3 seconds. Be sure to complete
soldering procedures under these conditions of temperature and
time.
Be careful to select a type of flux that will neither corrode the
lead wires nor affect the electrical characteristics of a sensor.
The basic precautions for soldering procedures are as follows :
(a) Complete soldering procedures in a time as short as possible.
(b) Do not apply stress to a sensor after soldering by correcting
or modifying its location or direction.
(c) For a sensor employing a heat sink, mount it on the heat sink
first: then solder this unit to a printed circuit board after
confirming that it is fully secured.
(d) Do not directly solder the heat-radiating portion of a sensor
to a printed circuit board.
(e) In flow solder jobs, sensors are apt to float on the solder due
to solder surface tension. When adjusting the locations of
sensor, be careful not to apply excessive stress to the roots of
the sensor lead wires.
(f) When using a soldering iron select those which have less
leakage, and be sure to ground the soldering iron.
3. Cleaning a circuit board
After soldering, circuit boards must be cleaned to remove flux.
Observe the following precautions while cleaning them
(a) When cleaning circuit boards to remove flux, make sure that
no residual reactive ions such as Na or Cl ions remain. Note
that organic solvents react with water to generate hydrogen
chloride and other corrosive gases which can degrade device
performance.
(b) Do not rub the indication marks with a brush or ones fingers
when cleaning or while a cleaning agent is applied to the
markings.
(c) There are ultrasonic wave cleaning methods which offer a
high cleaning effect within a short time. Since there methods
involve a complicated combination of factors such as the
cleaning bath size, ultrasonic wave vibrator output, and
printed circuit board mounting method, there is fear that the
service life of airtight seal-type sensors may be extremely
shortened. Therefore, as far as possible avoid using the
ultrasonic wave cleaning method.
- Basic requirements of ultrasonic wave cleaning method.
Frequency : 27~29kHz
Output : 300W or less (300W/ or less)
Recommended solvents : Refer to details above
Cleaning time : 30seconds or less
Application circuit
The Pressure sensor is designed to convert a voltage by means of
constant current drive and then, if nesessary, it amplifies the
voltage for use. The circuit shown below is a typical example of a
circuit in which the pressure sensor is used.
Constant Current
Circuit Unit
Pressure
Sensor
Amplifier Circuit Unit
OP
AMP
OP
AMP
OP
AMP
2007. 6. 15
Revision No : 8
4/4

4페이지












구       성 총 4 페이지수
다운로드[ KPF801G03.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
KPF801G01

Semiconductor Pressure Sensor

KEC
KEC
KPF801G01A

Semiconductor Pressure Sensor

KEC
KEC

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵