부품번호 K3HB-R 기능
기능 Rotary Pulse Indicator
제조업체 Omron
로고 Omron 로고


K3HB-R 데이터시트 를 다운로드하여 반도체의 전기적 특성과 매개변수에 대해 알아보세요.




전체 6 페이지수

미리보기를 사용할 수 없습니다

K3HB-R 데이터시트, 핀배열, 회로
Rotary Pulse Indicator
K3HB-R
Digital Rotary Pulse Meter Capable of 50 kHz
Measurements
• Measures High-speed Pulses at 50 kHz.
Provides high-speed pulse measurements up to 50 kHz of rotary
encoder or ON/OFF pulse signals and can perform rotating
measurement of high-speed rotating objects.
Note: No-voltage contacts of up to 30 Hz are supported.
• Six Measurement Operations Including Rotation (rpm)/
Circumferential Speed, Ratio, and Cumulative
One Rotary Pulse Meter has 6 rotary pulse measurement functions to
support a variety of pulse measurement applications. Select the best
function for your application from the following: rotation (rpm)/
circumferential speed, absolute ratio, error ratio, error, flow rate ratio,
and passing time.
Refer to Common Precautions on page 30.
Model Number Structure
Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
Base Units with Optional Boards
K3HB-R @
K3HB-R@-@@@
15
1 234 5
1. Input Sensor Codes
NB: NPN input/voltage pulse input
PB: PNP input
5. Supply Voltage
100-240 VAC:100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Optional Board
Sensor Power Supply/Output Boards
K33-@
2
Relay/Transistor Output Boards
K34-@
3
Event Input Boards
K35-@
4
2. Sensor Power Supply/Output Type Codes
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
L1A: Linear current output (DC0(4)-20 mA) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
L2A: Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
A: Sensor power supply (12 VDC ±10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
3. Relay/Transistor Output Type Codes
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
4. Event input Type Codes
None: None
1: 5 points (M3 terminal blocks) NPN open collector
2: 8 points (10-pin MIL connector) NPN open collector
3: 5 points (M3 terminal blocks) PNP open collector
4: 8 points (10-pin MIL connector) PNP open collector
Note: 1. CPA can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator:
RS-232C/RS-485 communications, BCD communications, or DeviceNet communications.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable
4 Rotary Pulse Indicator K3HB-R




K3HB-R pdf, 반도체, 판매, 대치품
Operation
Functions (Operating Modes)
F1 to F6
Functions F1 to F6 provide rpm/circumferential speed and other calculation displays by measuring continuous pulses (frequencies).
Example
Length of
processing stage
Function name
Rpm/circumferential
speed
Absolute ratio
Error ratio
Rotational difference
Flow rate ratio
Passing time
Function No.
f1
f2
f3
f4
f5
f6
F1: Displays rotation (rpm) or circumferential speed for one input.
F2 to F5: Displays the calculation result for two rotation (rpm) speeds.
F6: Displays the passing time calculated from the circumferential speed and the length
of the processing stage for one input.
The basic principle used by the Digital Indicator to calculate the rotation speed (rpm) display is
to count the ON/OFF time (T) for input sensor or other device inputs using the internal system
clock, and then automatically calculate the frequency. This frequency (f) is multiplied by 60 and
displayed as the rotation (rpm) speed.
Input sensor or other input pulse ON/OFF time (T) =
T
Frequency (f) =
1
T
Rotation speed (rpm) = f × 60
Circumferential speed = Roll circumference × Rotation speed (rpm)
Passing time= Length of processing stage
Circumferential speed
These calculations are automatically made internally and displayed whenever any input pulse
is received.
Function
Operation
F1
Rpm/cir-
cumferen-
tial speed/
Instanta-
neous
flowrate
Measures frequency for input A and displays the
rotation (rpm) or circumferential speed proportional to
the input frequency.
Calculation
Rotation
speed
Display
unit
rpm
rps
Prescale value (α)
1/N
1/60 N
Frequency (of
input pulse)
Circumferenti
al speed
Hz
kHz
mm/s
cm/s
m/s
m/min
1/60
1/60000
1000 πd/60 N
100 πd/60 N
πd/60 N
πd/N
Instantaneous
flowrate
km/h
l/min
l/h
0.06 πd/N
Check the output
specifications of the input
device and calculate the
prescale value from the
following equation:
Display value D = ƒa × 60 ×
α
N = Pulses per rotation
πd = Circumferential length per rotation
Operation image (application)
Measuring roller winding speed
Measuring motor speed
(for product testing)
H
PASS
L
OK/NG
judgment
Rotary Pulse Indicator K3HB-R
7

4페이지












구       성 총 6 페이지수
다운로드[ K3HB-R.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
K3HB-C

Digital Indicators User Manual

Omron
Omron
K3HB-C

Up/Down Counting Pulse Indicator

Omron
Omron

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵