DataSheet.es    


PDF K3HB-P Data sheet ( Hoja de datos )

Número de pieza K3HB-P
Descripción Timer Interval Indicator
Fabricantes Omron 
Logotipo Omron Logotipo



Hay una vista previa y un enlace de descarga de K3HB-P (archivo pdf) en la parte inferior de esta página.


Total 5 Páginas

No Preview Available ! K3HB-P Hoja de datos, Descripción, Manual

Timer Interval Indicator
K3HB-P
Digital Time Interval Meter for Measuring
Passing Speed, Time, or Cycle between Two
Points.
• Measures Wide Range of Pulse Interval Times
Measures, calculates, and displays pulse intervals between two
points. Wide range for pulse interval measurements, from 10 ms to
3,200 s, max.
• Six Measurement Operations, Including Passing Speed, Time,
and Cycle Measurement between Two Points
One Digital Time Interval Meter has six measurement functions, to
support a variety of pulse interval measurement applications. Select
the best function for your application from the following: Passing
speed, cycle, time difference, time band, measuring length, and
interval.
Refer to Common Precautions on page 30.
Model Number Structure
Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
Base Units with Optional Boards
K3HB-P @
K3HB-P@-@@@
15
1 234 5
1. Input Sensor Codes
NB: NPN input/voltage pulse input
PB: PNP input
5. Supply Voltage
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Optional Board
Sensor Power Supply/Output Boards
K33-@
2
Relay/Transistor Output Boards
K34-@
3
Event Input Boards
K35-@
4
2. Sensor Power Supply/Output Type Codes
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
L1A: Linear current output (DC0(4)-20 mA) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
L2A: Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
A: Sensor power supply (12 VDC ±10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
3. Relay/Transistor Output Type Codes
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
4. Event input Type Codes
None: None
1: 5 points (M3 terminal blocks) NPN open collector
2: 8 points (10-pin MIL connector) NPN open collector
3: 5 points (M3 terminal blocks) PNP open collector
4: 8 points (10-pin MIL connector) PNP open collector
Note: 1. CPA can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator:
RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable
10 Timer Interval Indicator K3HB-P

1 page




K3HB-P pdf
Function
Operation
F4
Time band
Displays input A ON time (T).
Input A
HOLD input
T1
TR
T2
TR
T3
Operation image (application)
Monitoring the ON time of a printing
press
Managing the valve release
time
Communications
output
Display
T1 T3
F5
Measuring
length
Measurement range: 10 ms to 3,200 s
Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit: ö
ç
ç
è
ms, s, min.,
min.s.1/10 s
÷
÷
ø
Displays the number of input A pulses while input B is
ON.
123456
12345
Measuring workpiece length
Input A
BCD
To Programmable Controller
Input B
HOLD input
F6
Interval
Display
65
Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit:
ö
ç
è
mm,
cm,
m,
etc.
÷
ø
Displays the number of input A pulses from when input
B turns ON until input B turns ON again. Measurement
is made every other time input B turns ON.
Measuring slit intervals
1234
12 34
12 1
Input A
Input B
HOLD input
TR
TR
H
PASS
L
OK judgment
Display
34
Recovery time (TR) of 20 ms is required before
starting the next measurement.
æ Display unit:
ö
ç
è
mm,
cm,
m,
etc.
÷
ø
INA
INB
Display
12 3
12 12
TR TR
32
What Is Prescaling?
To make calculations using the input pulse to display the passing speed between two points, the distance between the two points and the display
unit must be set and the internally measured time multiplied by a certain coefficient. This coefficient is called the prescale value. (For information
on settings details, refer to the User's Manual.)
Time Unit Settings
Setting
Meaning
scal
Prescale value menu setting
min Minute display
h.mm.ss
mm.ss.d
h.mm.ss display
mm.ss.d display (d = tenths of a second)
Input Type Setting
No-contact or
voltage pulse
input
Contact
NO: Voltage pulse high NC: Voltage pulse low
00 01
10 11
Note: Set to 10 or 11 when there is a large variation in the display.
The largest measurement range is 30 Hz.
14 Timer Interval Indicator K3HB-P

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet K3HB-P.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
K3HB-CDigital Indicators User ManualOmron
Omron
K3HB-CUp/Down Counting Pulse IndicatorOmron
Omron
K3HB-HTemperature IndicatorOmron
Omron
K3HB-PDigital Indicators User ManualOmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar