Número de pieza | HFA100 | |
Descripción | Multicontact Auxiliary Relays | |
Fabricantes | GE | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de HFA100 (archivo pdf) en la parte inferior de esta página. Total 5 Páginas | ||
No Preview Available ! HFA100
Multicontact Auxiliary Relays
For AC and DC circuit applications.
Description
HFA Century Series relays are designed for
applications where a number of auxiliary
functions must be performed simultane-
ously. The Century Series coil design
provides longer operating life than
previeous designs as a result of changes in
the entire coil insulation system.
The six electrically separate contcact
circuits are adaptable for either circuit-
opening or circuit-closing applications. If
more than six circuits are to be controlled,
the coils of two or more relays may be
connected in series (DC only) or in parallel.
HFA Century Series relays are offered in
non-drawout case or drawout case
construction.
Non-drawout cas HFA relays are available
for front connection (suitable for surface
mounting only) or back connection (suit-
able for semi-flush mounting only).
Drawout case HFA relays are back-connect-
ed and are suitable for either semi-fluch or
surface mounting.
GE Multilin
1
1 page HFA100 Multicontact Auxiliary Relays
Electric Reset Relays
TABLE A lists the combination of reset and mounting avail-
able.
TABLE B lists the voltage and frequencies of the operating
and reset coils.
TABLE C shows the variaous contact configurations avail-
able.
To obtain a complete catalogue number, select the basic
number from Table A; insert the form number from Table
B; specify the contact code fromTable C.
Example:
Electric reset only
Front
connected
Surface mounting
} Select HFA154E-H from
Table A
48V DC operate coil
120V 60 Hz reset coil
} Select form number 44
fromTable B
3 N.O. and 2 N.C.
contacts
} Select contact code 42
fromTable C
Thus, HFA154E44H code 42 is the complete relay number.
Table A
Selection of HFA Electric Reset Models
Type of
Reset
Mounting
Contact Basic Number ቢ Weight lbs(kg)
s Net Ship
Electric Back connected
and semi-flush
Hand
Reset
Front connected
Surface mounted
Back connected
drawout case
Table C
HFA154B-F
A154B-H
A174B-A
5
(2.3)
5
(2.3)
12
(5.4)
7
(3.2)
7
(3.2)
18
(8.2)
Electric Back connected
Reset semi-flush
Only Front connected
Surface mounted
Back connected
drawout case
Table C
HFA154E-F
A154E-H
A174E-A
5
(2.3)
5
(2.3)
12
(5.4)
7
(3.2)
7
(3.2)
18
(8.2)
ቢ On hand and electric resetTypes HFA154B, 174B, 154E
and 174E one contact is wired in series with reset coil
to provide positive cutoff.Thus five contacts are avail-
able for external circuits.
Table B
Selection guide - form numbers
Voltage and
Reset Coil Rating Form Numbers
Frequency 110 DC 125 DC 220 DC 250 DC 120 DC 60 Hz 120 DC 50 Hz
O 6V DC
P 12V DC
E
R
A
24V DC
32V DC
T 48V DC
E
27
26
25
33 13
24
62.5V DC
23
C
O
110V DC
32
12
I 125V DC
22
L 220V DC 31
11
250V DC
21
R
A
T
120V 60 Hz
I 240V 60 Hz
29
28
N 120V 50 Hz 39
19
G 240V 50 Hz 38
18
7
6
5
4
3
2
1
9
8
47
46
45
44
43
42
41
49
48
53
52
51
59
58
5
Operating Characteristics
Model
Number
Pickup Voltage in Percent of Rating
Hot Cold
Dropout Voltage in Percent of Rating
AC DC
Operating Time at Rated Voltage to
Close a N.O. Contact
AC DC
Operating time to open a N.O. contact
when voltage reduced to zero
AC DC
HFA151A, -B
HFA171A, -B
80 or Less, AC 60 DC 80AC or
or DC
Higher
30 - 60
2 - 10
33 ms or Less 84 ms or Less 14 ms or Less 28 ms or Less
HFA153K
HFA173K
8 or Less (DC 6 or Less (DC
Only)
Only)
--
2 - 10
9 ms or Less forTripping Duty
9 ms or Less
www.GEindustrial.com/Multilin
5
5 Page |
Páginas | Total 5 Páginas | |
PDF Descargar | [ Datasheet HFA100.PDF ] |
Número de pieza | Descripción | Fabricantes |
HFA100 | Multicontact Auxiliary Relays | GE |
HFA100MD60C | HEXFRED Ultrafast/ Soft Recovery Diode | International Rectifier |
HFA105NH60 | HEXFRED Ultrafast/ Soft Recovery Diode | International Rectifier |
HFA105NH60R | HEXFRED Ultrafast/ Soft Recovery Diode | International Rectifier |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |