INCH-POUND
DETAIL SPECIFICATION SHEET
MS24185M
15 April 2003
SUPERSEDING
MS24185L
10 Jan 1994
RELAYS, ELECTROMAGNETIC, 400 AMPERES, 1 PST (N.O.),
TYPE II, NONHERMETICALLY SEALED
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
The requirements for acquiring the relay described herein shall
consist of this specification and the latest issue of MIL-PRF-6106.
FIGURE 1. Dimensions and configurations.
AMSC N/A
1 of 6
DISTRIBUTION STATEMENT A. Approved for public release, distribution is unlimited.
FSC 5945

1 page




MS24185M pdf
MS24185M
Shock g-level: 25 g’s.
Duration: 6-9 ms.
Maximum duration contact opening: 2 ms.
Vibration - sinusoidal: See table IV.
Vibration - random: N/A.
High shock: N/A.
Acceleration: 10 g’s.
Qualification by similarity: See MIL-PRF-6106.
Part or Identifying Number (PIN): MS24185- (plus applicable dash number from table I).
TABLE I. PIN and general characteristics.
Part number
MS24185-
Type
Coil type
Terminal type Mounting or mating
socket
D1 1/ 3/
D2 2/ 3/
II
II
dc
Stud
Bracket - bottom
dc
Stud
Bracket - side
1/ For Government logistics support, MS24185-D1 shall be used in lieu of AN3380-2.
2/ For Government logistics support, MS24185-D2 shall be used in lieu of AN3380-1.
3/ For similar relays with transient suppressed coils see MIL-PRF-6106/56.
Maximum
weight
in pounds
2.6
2.6
TABLE II. Rated contact load (amperes per pole) case grounded.
Type of load
Life
operat
ing
cycles
x 103
Resistive
Inductive
Motor
Lamp
Transfer load
Mechanical life
reduced
current
Mixed loads
50
10
50
100
50
28 V dc
Main
NO NC
Aux
NO NC
400
100
400
100
40
115 V ac, 1 phase
Main
400 60
Hz Hz
Aux
400 60
Hz Hz
115/200 V ac, 3 phase 1/
Main
400 60
Hz Hz
Aux
400 60
Hz Hz
See
appro-
priate
notes
2/
1/ Absence of value indicates parameter is not applicable to this specification sheet.
2/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power
supplies at the rating indicated.
5

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet MS24185M.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MS24185MRELAYSETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar