Features
Precision Relative Humidity Sensor Drop-In Upgrade for Si7005
± 4.5% RH (max), 0–80% RH
Factory-calibrated
High-Accuracy Temperature Sensor I2C Interface
±1 ºC (max), –10 to 85 °C
0 to 100% RH operating range
Integrated on-chip heater
4x4 mm QFN package
0 to +70 °C operating range (FM)
Excellent long term stability
–40 to +85 °C operating range (GM)
Optional factory-installed
Low Voltage Operation (1.9 to 3.6 V)
cover
Low Power Consumption
Low-profile
150 µA active current
Protection during reflow
60 nA standby current
Excludes liquids and
particulates
Applications
HVAC/R
Thermostats/humidistats
Instrumentation
White goods
Micro-environments/data centers
Industrial controls
Weather stations
Asset tracking and storage
Description
The Si7015 I2C Humidity and Temperature Sensor is a monolithic CMOS
IC integrating humidity and temperature sensor elements, an analog-to-
digital converter, signal processing, calibration data, and an I2C Interface.
The patented use of industry-standard, low-K polymeric dielectrics for
sensing humidity enables the construction of low-power, monolithic
CMOS Sensor ICs with low drift and hysteresis and excellent long term
stability.
Each unit is factory-calibrated, and the calibration data is stored in the on-
chip non-volatile memory. This ensures that the sensors are fully
interchangeable, with no recalibration or software changes required. The
Si7015 can be used as a drop-in upgrade for the Si7005 with only minor
software changes because the register sets are the same, and the
4x4 mm QFN package is footprint-compatible with that of the Si7005.
The device is compatible with standard SMT assembly processes, such
as reflow. The optional factory-installed cover offers a low profile and
convenient means of protecting the sensor during assembly (e.g., reflow
soldering) and throughout the life of the product, excluding liquids
(hydrophobic/oleophobic) and particulates.
The Si7015 offers an accurate, low-power, factory-calibrated digital
solution ideal for measuring humidity, dew-point, and temperature in
applications ranging from HVAC/R and asset tracking to industrial and
consumer platforms.
Ordering Information
See page 31.
Patent protected; patents pending
Pin Assignments
GND
DNC
1
2
SCL
SDA
DNC
3
4
5
DNC 6
18 DNC
17 DNC
16 DNC
15 CS
14 DNC
13 DNC
Rev. 1.0 1/15
Copyright © 2015 by Silicon Laboratories
Si7015-A20

1 page




SI7015-A20 pdf
Si7015-A20
Table 2. General Specifications (Continued)
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or 0 to 70 °C (F grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition1
Min Typ Max Unit
Wake Up Time
tCS From CS < VIL to ready for a temp/RH
1 ms
conversion
Power Up Time
tPU From VDD 1.9 V to ready for a temp/
RH conversion, 25°C
From VDD 1.9 V to ready for a temp/
RH conversion, full temperature range
18 25 ms
— 80 ms
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Read Device ID and Read Firmware Version. Duration is < 100 µs when I2C clock
speed is >100 kHz.
Table 3. I2C Interface Specifications1
1.9VDD 3.6 V; TA = 0 to 70 °C (F grade) or –40 to +85 °C (G grade) unless otherwise noted.
Parameter
Symbol
Test Condition
Min Typ
Hysteresis
VHYS
High-to-low versus low-to- 0.05 x VDD
high transition
SCLK Frequency
fSCL
SCL High Time
tSKH
SCL Low Time
tSKL
Start Hold Time
tSTH
Start Setup Time
tSTS
Stop Setup Time
tSPS
Bus Free Time
tBUF Between Stop and Start
SDA Setup Time
tDS
SDA Hold Time
tDH
SDA Valid Time
tVD;DAT From SCL low to data valid
SDA Acknowledge Valid Time
Suppressed Pulse Width2
tVD;ACK From SCL low to data valid
tSP
Notes:
1. All values are referenced to VIL and/or VIH.
2. Pulses up to and including 50ns will be suppressed.
0.6
1.3
0.6
0.6
0.6
1.3
100
100
50
Max Unit
—V
400 kHz
— µs
— µs
— µs
— µs
— µs
— µs
— ns
— ns
0.9 µs
0.9 µs
— ns
Rev. 1.0
5

5 Page





SI7015-A20 arduino
Si7015-A20
3. Bill of Materials
Table 8. Typical Application Circuit BOM*
Reference
Description
Mfr Part Number
Manufacturer
C1
Capacitor, 0.1 µF, 6.3 V, X7R, 0603
C0603X7R6R3-104M
Venkel
R1*
Resistor, 10 k, ±5%, 1/16 W, 0603
CR0603-16W-1002J
Venkel
R2*
Resistor, 10 k, ±5%, 1/16 W, 0603
CR0603-16W-1002J
Venkel
U1 IC, digital temperature/humidity sensor
Si7015-A20
Silicon Labs
*Note: Typical value shown. Optimal value depends on bus capacitance and speed of bus operation; not needed if present
elsewhere in the system.
Rev. 1.0
11

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet SI7015-A20.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SI7015-A20DIGITAL I2C HUMIDITY AND TEMPERATURE SENSORSilicon Laboratories
Silicon Laboratories

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar