XU1010-QH
Up Converter
17.0-34.0 GHz
Features
Integrated Balanced Mixer, LO Buffer and LO
Doubler
+23.0 dBm Input Third Order Intercept (IIP3)
+2.0 dBm LO Drive Level
4x4mm QFN Package
100% RF and DC Testing
RoHS* Compliant and 260°C Reflow Compatible
Description
M/A-COM Tech’s 17.0-34.0 GHz GaAs
packaged up-converter has an input third order
intercept point of +23.0 dBm and 10.0 dB of
conversion loss. The device consists of a
balanced resistive pHEMT mixer, LO buffer
amplifier and LO doubler packaged in an
industry standard, fully molded 4x4mm QFN
package. IF and *IF mixer inputs are provided
and an external 180 degree hybrid is required.
The device includes on-chip ESD protection
structures and DC by-pass capacitors to ease
the implementation and volume assembly of the
packaged part. This device is well suited for
Millimeter-wave Point-to-Point Radio, LMDS,
SATCOM and VSAT applications.
Absolute Maximum Ratings1
Parameter
Absolute Max.
Drain Voltage Supply (Vdd)
Drain Current (Ids)
Input Power (Pin) IF
Input Power (Pin) LO
Storage Temperature (Tstg)
Operating Temperature (Tb)
ESD Min. - Machine Model (MM)
ESD Min. - Human Body Model
(HBM)
MSL Level
+4.3 V
350 mA
+5 dBm
+10 dBm
-65 °C to +165 °C
-55 °C to +85 °C
Class A
Class 0
MSL3
(1) Operation of this device above any one of these parameters may
cause permanent damage.
Functional Block Diagram
NC GND RF GND NC VG2,3
Rev. V2
GND 1
IF1 2
NC 3
NC 4
IF2 5
GND 6
ESD
ESD
MIXER
0o
180 o
BUF
x2
18 VG1
17 VSS
16 GND
15 GND
14 VD2
13 VD1
789
NC GND LO GND NC NC
Pin Configuration
Pin No.
1
2
3-4
5
6-8
7
Function
Ground
IF1 Input
Not Connected
IF2 Input
Ground
Not Connected
Pin No.
14
15-16
17
18
19
20
Function
LO Doubler
Drain
Ground
Doubler/ESD
Bias
LO Buffer Gate
LO Doubler/
Mixer Gate
Not Connected
8 Ground 21 Ground
9 LO Input 22 RF Input
10 Ground 23 Ground
11-12 Not Connected 24 Not Connected
13 LO Buffer Drain
Ordering Information
Part Number
XU1010-QH-0G00
XU1010-QH-0G0T
XU1010-QH-EV1
Package
bulk quantity
tape and reel
evaluation module
1
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
India Tel: +91.80.43537383
China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.




XU1010-QH pdf, 반도체, 판매, 대치품
XU1010-QH
Up Converter
17.0-34.0 GHz
Rev. V2
App Note [1] Biasing - As shown in the Pin Designations table, the device is operated by biasing VD1 and VD2
at 4.0 V with 130 mA and approximately 60 mA respectively. VG2,3 and VSS require fixed voltage biasing with
VSS biased at -4.0 V and 45 mA. It is recommended to use active bias on VG1 to keep the current in VD1 con-
stant in order to maintain the best performance over temperature. Depending on the supply voltage available
and the power dissipation constraints, the bias circuit may be a single transistor or a low power operational am-
plifier, with a low value resistor in series with the drain supply used to sense the current. The gate of the pHEMT
is controlled to maintain correct drain current and thus drain voltage. The typical gate voltage needed to do this
is -0.2 V. Make sure to sequence the applied voltage to ensure negative gate bias is available before applying
the positive drain supply.
App Note [2] Board Layout - As shown in the board layout, it is recommended to provide 100pF decoupling
caps as close to the bias pins as possible, with additional 10μF decoupling caps.
Recommended Board Layout
4
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
India Tel: +91.80.43537383
China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.

4페이지












구       성 총 5 페이지수
다운로드[ XU1010-QH.PDF 데이터시트 ]

당사 플랫폼은 키워드, 제품 이름 또는 부품 번호를 사용하여 검색할 수 있는

포괄적인 데이터시트를 제공합니다.


구매 문의
일반 IC 문의 : 샘플 및 소량 구매
-----------------------------------------------------------------------

IGBT, TR 모듈, SCR 및 다이오드 모듈을 포함한
광범위한 전력 반도체를 판매합니다.

전력 반도체 전문업체

상호 : 아이지 인터내셔날

사이트 방문 :     [ 홈페이지 ]     [ 블로그 1 ]     [ 블로그 2 ]



관련 데이터시트

부품번호상세설명 및 기능제조사
XU1010-QH

Up Converter

MA-COM
MA-COM

DataSheet.kr       |      2020   |     연락처      |     링크모음      |      검색     |      사이트맵